configfs_lookup(): don't leave ->s_dentry dangling on failure
Normally ->s_dentry is cleared when dentry it's pointing to becomes
negative (on eviction, realistically). However, that only happens
if dentry gets to be positive in the first place; in case of inode
allocation failure dentry never becomes positive, so ->d_iput()
is not called at all.
We do part of what normally would've been done by configfs_d_iput()
(dropping the reference to configfs_dirent) manually, but we do
not clear ->s_dentry there. Sloppy as it is, it does not matter in
case of configfs_create_{dir,link}() - there configfs_dirent does
not survive dropping the sole reference to it.
However, for configfs_lookup() it *does* survive, with a dangling
pointer to soon to be freed dentry sitting it its ->s_dentry.
Subsequent getdents(2) in that directory will end up dereferencing
that pointer in order to pick the inode number. Use after free...
This is the minimal fix; the right approach is to set the linkage
between dentry and configfs_dirent only after we know that we have
an inode, but that takes more surgery and the bug had been there
since 2006, so...
Analysis and contextual insights are available on OpenCVE Cloud.
No vendor fix or workaround currently provided.
Additional remediation guidance may be available on OpenCVE Cloud.
Tracking
Sign in to view the affected projects.
No advisories yet.
Sat, 15 Aug 2026 13:15:00 +0000
| Type | Values Removed | Values Added |
|---|---|---|
| Weaknesses | CWE-416 |
Sat, 15 Aug 2026 06:15:00 +0000
| Type | Values Removed | Values Added |
|---|---|---|
| Description | In the Linux kernel, the following vulnerability has been resolved: configfs_lookup(): don't leave ->s_dentry dangling on failure Normally ->s_dentry is cleared when dentry it's pointing to becomes negative (on eviction, realistically). However, that only happens if dentry gets to be positive in the first place; in case of inode allocation failure dentry never becomes positive, so ->d_iput() is not called at all. We do part of what normally would've been done by configfs_d_iput() (dropping the reference to configfs_dirent) manually, but we do not clear ->s_dentry there. Sloppy as it is, it does not matter in case of configfs_create_{dir,link}() - there configfs_dirent does not survive dropping the sole reference to it. However, for configfs_lookup() it *does* survive, with a dangling pointer to soon to be freed dentry sitting it its ->s_dentry. Subsequent getdents(2) in that directory will end up dereferencing that pointer in order to pick the inode number. Use after free... This is the minimal fix; the right approach is to set the linkage between dentry and configfs_dirent only after we know that we have an inode, but that takes more surgery and the bug had been there since 2006, so... | |
| Title | configfs_lookup(): don't leave ->s_dentry dangling on failure | |
| First Time appeared |
Linux
Linux linux Kernel |
|
| CPEs | cpe:2.3:o:linux:linux_kernel:*:*:*:*:*:*:*:* | |
| Vendors & Products |
Linux
Linux linux Kernel |
|
| References |
|
|
Status: PUBLISHED
Assigner: Linux
Published:
Updated: 2026-08-15T05:58:43.456Z
Reserved: 2026-08-15T05:44:03.887Z
Link: CVE-2026-74359
No data.
Status : Received
Published: 2026-08-15T06:22:37.430
Modified: 2026-08-15T06:22:37.430
Link: CVE-2026-74359
No data.
OpenCVE Enrichment
Updated: 2026-08-15T13:00:05Z