Export limit exceeded: 424983 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Search
Search Results (424983 CVEs found)
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2026-12265 | 1 Zohocorp | 1 Ddi Central | 2026-11-10 | 8.8 High |
| Zoho Corporation ManageEngine DDI Central versions 6200 and below are vulnerable to insufficient access control in HA failover endpoint leading to destructive PostgreSQL database operations. | ||||
| CVE-2026-12264 | 1 Zohocorp | 1 Ddi Central | 2026-11-10 | 8.8 High |
| Zoho Corporation ManageEngine DDI Central versions 6200 and below are vulnerable to arbitrary file write via HA Failover Config sync upload leading to code execution as root. | ||||
| CVE-2026-112137 | 2026-11-10 | 5.4 Medium | ||
| A vulnerability has been identified in Mendix Studio Pro 11 (All versions >= V11.15.0 < V11.16.0), Mendix Studio Pro 11.12 (All versions >= V11.12.6 < V11.12.7). The affected products MCP Server does not properly validate Content-Type and Origin headers on incoming HTTP requests, leaving it vulnerable to Cross-Site Request Forgery (CSRF). This could allow a malicious web page to trick a user's browser into sending unauthorized requests and executing unintended actions on the local MCP Server. | ||||
| CVE-2026-109097 | 2026-11-10 | 8.2 High | ||
| A vulnerability has been identified in ROS# (All versions < V2.3.1). Affected systems do not properly escape text of message definition files. This could allow an attacker that is able to pass a crafted message definition file to the user to inject arbitrary code into the generated program. | ||||
| CVE-2026-64629 | 1 Siemens | 1 Parasolid | 2026-11-10 | 7.8 High |
| A vulnerability has been identified in Parasolid V38.0 (All versions < V38.0.235), Parasolid V38.1 (All versions < V38.1.230), Simcenter Femap (All versions < V2606.0002). The affected applications contains an out of bounds read vulnerability while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. | ||||
| CVE-2026-59082 | 2026-11-10 | 7.8 High | ||
| A vulnerability has been identified in SIMATIC WinCC V7.5 (All versions), SIMATIC WinCC V8.0 (All versions), SIMATIC WinCC V8.1 (All versions). Affected devices implicitly execute active content when opening files. This could allow an attacker to make the user execute arbitrary code on the device. | ||||
| CVE-2026-58115 | 1 Siemens | 1 Simatic Iot2050 | 2026-11-10 | 10 Critical |
| A vulnerability has been identified in SIMATIC IoT2050 Advanced (6ES7647-0BA00-1YA2) (All versions < V4.3.4-1 running Industrial OS with Node-RED installed), SIMATIC IoT2050 Advanced (6ES7647-0BA00-1YA2) (All versions running Example Image versions with Node-RED installed), SIMATIC IoT2050 Basic (6ES7647-0BA00-0YA2) (All versions < V4.3.4-1 running Industrial OS with Node-RED installed), SIMATIC IoT2050 Basic (6ES7647-0BA00-0YA2) (All versions running Example Image versions with Node-RED installed), SIMATIC IoT2050 M.2 (6ES7647-0BB00-1YA2) (All versions < V4.3.4-1 running Industrial OS with Node-RED installed), SIMATIC IoT2050 M.2 (6ES7647-0BB00-1YA2) (All versions running Example Image versions with Node-RED installed), SIMATIC IoT2050 SM (6ES7647-0CA00-1AA2) (All versions < V4.3.4-1 running Industrial OS with Node-RED installed), SIMATIC IoT2050 SM (6ES7647-0CA00-1AA2) (All versions running Example Image versions with Node-RED installed). Affected devices do not enforce authentication on the Node-RED HTTP interface, allowing unauthenticated access to programming nodes that are capable of executing system commands on the server. This could allow an unauthenticated remote attacker to create malicious flows through the HTTP interface in order to execute arbitrary code on the underlying server with maximum privileges. | ||||
| CVE-2025-40759 | 2026-11-10 | 7.8 High | ||
| A vulnerability has been identified in SIMATIC S7-PLCSIM V17 (All versions), SIMATIC STEP 7 V17 (All versions < V17 Update 9), SIMATIC STEP 7 V18 (All versions < V18 Update 6), SIMATIC STEP 7 V19 (All versions < V19 Update 4), SIMATIC STEP 7 V20 (All versions < V20 Update 4), SIMATIC WinCC V17 (All versions < V17 Update 9), SIMATIC WinCC V18 (All versions < V18 Update 6), SIMATIC WinCC V19 (All versions < V19 Update 4), SIMATIC WinCC V20 (All versions < V20 Update 4), SIMOCODE ES V17 (All versions), SIMOCODE ES V18 (All versions), SIMOCODE ES V19 (All versions), SIMOCODE ES V20 (All versions), SIMOTION SCOUT TIA V5.4 (All versions), SIMOTION SCOUT TIA V5.5 (All versions), SIMOTION SCOUT TIA V5.6 (All versions < V5.6 SP1 HF7), SIMOTION SCOUT TIA V5.7 (All versions), SINAMICS Startdrive V17 (All versions), SINAMICS Startdrive V18 (All versions), SINAMICS Startdrive V19 (All versions), SINAMICS Startdrive V20 (All versions), SIRIUS Safety ES V17 (TIA Portal) (All versions), SIRIUS Safety ES V18 (TIA Portal) (All versions), SIRIUS Safety ES V19 (TIA Portal) (All versions), SIRIUS Safety ES V20 (TIA Portal) (All versions), SIRIUS Soft Starter ES V17 (TIA Portal) (All versions), SIRIUS Soft Starter ES V18 (TIA Portal) (All versions), SIRIUS Soft Starter ES V19 (TIA Portal) (All versions), SIRIUS Soft Starter ES V20 (TIA Portal) (All versions), TIA Portal Cloud V17 (All versions < V6.0.0.0), TIA Portal Cloud V18 (All versions < V6.3.0.2), TIA Portal Cloud V19 (All versions < V5.2.1.1), TIA Portal Cloud V20 (All versions < V5.2.2.2). Affected products do not properly sanitize stored security properties when parsing project files. This could allow an attacker to cause a type confusion and execute arbitrary code within the affected application. | ||||
| CVE-2025-40742 | 2026-11-10 | 5.3 Medium | ||
| A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions < V11.0), SIPROTEC 5 6MD85 (CP300) (All versions < V11.0), SIPROTEC 5 6MD86 (CP300) (All versions < V11.0), SIPROTEC 5 6MD89 (CP300) (All versions < V11.0), SIPROTEC 5 6MD89 (CP300) V9.6x (All versions < V11.0), SIPROTEC 5 6MU85 (CP300) (All versions < V11.0), SIPROTEC 5 7KE85 (CP300) (All versions < V11.0), SIPROTEC 5 7SA82 (CP100) (All versions < V8.91), SIPROTEC 5 7SA82 (CP150) (All versions < V11.0), SIPROTEC 5 7SA86 (CP300) (All versions < V11.0), SIPROTEC 5 7SA87 (CP300) (All versions < V11.0), SIPROTEC 5 7SD82 (CP100) (All versions < V8.91), SIPROTEC 5 7SD82 (CP150) (All versions < V11.0), SIPROTEC 5 7SD86 (CP300) (All versions < V11.0), SIPROTEC 5 7SD87 (CP300) (All versions < V11.0), SIPROTEC 5 7SJ81 (CP100) (All versions < V8.91), SIPROTEC 5 7SJ81 (CP150) (All versions < V11.0), SIPROTEC 5 7SJ82 (CP100) (All versions < V8.91), SIPROTEC 5 7SJ82 (CP150) (All versions < V11.0), SIPROTEC 5 7SJ85 (CP300) (All versions < V11.0), SIPROTEC 5 7SJ86 (CP300) (All versions < V11.0), SIPROTEC 5 7SK82 (CP100) (All versions < V8.91), SIPROTEC 5 7SK82 (CP150) (All versions < V11.0), SIPROTEC 5 7SK85 (CP300) (All versions < V11.0), SIPROTEC 5 7SL82 (CP100) (All versions < V8.91), SIPROTEC 5 7SL82 (CP150) (All versions < V11.0), SIPROTEC 5 7SL86 (CP300) (All versions < V11.0), SIPROTEC 5 7SL87 (CP300) (All versions < V11.0), SIPROTEC 5 7SS85 (CP300) (All versions < V11.0), SIPROTEC 5 7ST85 (CP300) (All versions < V11.0), SIPROTEC 5 7ST86 (CP300) (All versions < V11.0), SIPROTEC 5 7SX82 (CP150) (All versions < V11.0), SIPROTEC 5 7SX85 (CP300) (All versions < V11.0), SIPROTEC 5 7SY82 (CP150) (All versions < V11.0), SIPROTEC 5 7UM85 (CP300) (All versions < V11.0), SIPROTEC 5 7UT82 (CP100) (All versions < V8.91), SIPROTEC 5 7UT82 (CP150) (All versions < V11.0), SIPROTEC 5 7UT85 (CP300) (All versions < V11.0), SIPROTEC 5 7UT86 (CP300) (All versions < V11.0), SIPROTEC 5 7UT87 (CP300) (All versions < V11.0), SIPROTEC 5 7VE85 (CP300) (All versions < V11.0), SIPROTEC 5 7VK87 (CP300) (All versions < V11.0), SIPROTEC 5 7VU85 (CP300) (All versions < V11.0), SIPROTEC 5 Compact 7SX800 (CP050) (All versions < V11.0). The affected devices include session identifiers in URL requests for certain functionalities. This could allow an attacker to retrieve sensitive session data from browser history, logs, or other storage mechanisms, potentially leading to unauthorized access. | ||||
| CVE-2024-54678 | 1 Siemens | 13 Simatic Pcs Neo, Simatic S7-plcsim, Simatic Step 7 and 10 more | 2026-11-10 | 8.2 High |
| A vulnerability has been identified in SIMATIC PCS neo V4.1 (All versions), SIMATIC PCS neo V5.0 (All versions), SIMATIC PCS neo V6.0 (All versions < V6.0 SP1 Update 1), SIMATIC S7-PLCSIM V17 (All versions), SIMATIC STEP 7 V17 (All versions < V17 Update 9), SIMATIC STEP 7 V18 (All versions < V18 Update 6), SIMATIC STEP 7 V19 (All versions < V19 Update 4), SIMATIC STEP 7 V20 (All versions < V20 Update 4), SIMATIC WinCC V17 (All versions < V17 Update 9), SIMATIC WinCC V18 (All versions < V18 Update 6), SIMATIC WinCC V19 (All versions < V19 Update 4), SIMATIC WinCC V20 (All versions < V20 Update 4), SIMOCODE ES V17 (All versions), SIMOCODE ES V18 (All versions), SIMOCODE ES V19 (All versions), SIMOCODE ES V20 (All versions), SIMOTION SCOUT TIA V5.4 (All versions < V17 Update 9), SIMOTION SCOUT TIA V5.5 (All versions < V18 Update 6), SIMOTION SCOUT TIA V5.6 (All versions < V19 Update 4), SIMOTION SCOUT TIA V5.7 (All versions < V20 Update 4), SINAMICS Startdrive V17 (All versions), SINAMICS Startdrive V18 (All versions), SINAMICS Startdrive V19 (All versions), SINAMICS Startdrive V20 (All versions), SIRIUS Safety ES V17 (TIA Portal) (All versions), SIRIUS Safety ES V18 (TIA Portal) (All versions), SIRIUS Safety ES V19 (TIA Portal) (All versions), SIRIUS Safety ES V20 (TIA Portal) (All versions), SIRIUS Soft Starter ES V17 (TIA Portal) (All versions), SIRIUS Soft Starter ES V18 (TIA Portal) (All versions), SIRIUS Soft Starter ES V19 (TIA Portal) (All versions), SIRIUS Soft Starter ES V20 (TIA Portal) (All versions), TIA Portal Cloud V17 (All versions < V6.0.0.0), TIA Portal Cloud V18 (All versions < V6.3.0.2), TIA Portal Cloud V19 (All versions < V5.2.1.1), TIA Portal Cloud V20 (All versions < V5.2.2.2), TIA Portal Test Suite V20 (All versions < V20 Update 4). Affected products do not properly sanitize Interprocess Communication input received through a Windows Named Pipe accessible to all local users. This could allow an authenticated local attacker to cause a type confusion and execute arbitrary code within the affected application. | ||||
| CVE-2024-49849 | 2026-11-10 | 7.8 High | ||
| A vulnerability has been identified in SIMATIC S7-PLCSIM V16 (All versions), SIMATIC S7-PLCSIM V17 (All versions), SIMATIC STEP 7 Safety V16 (All versions), SIMATIC STEP 7 Safety V17 (All versions < V17 Update 9), SIMATIC STEP 7 Safety V18 (All versions < V18 Update 6), SIMATIC STEP 7 Safety V19 (All versions < V19 Update 4), SIMATIC STEP 7 V16 (All versions), SIMATIC STEP 7 V17 (All versions < V17 Update 9), SIMATIC STEP 7 V18 (All versions < V18 Update 6), SIMATIC STEP 7 V19 (All versions < V19 Update 4), SIMATIC WinCC Unified V16 (All versions), SIMATIC WinCC Unified V17 (All versions < V17 Update 9), SIMATIC WinCC Unified V18 (All versions < V18 Update 6), SIMATIC WinCC Unified V19 (All versions < V19 Update 4), SIMATIC WinCC V16 (All versions), SIMATIC WinCC V17 (All versions < V17 Update 9), SIMATIC WinCC V18 (All versions < V18 Update 6), SIMATIC WinCC V19 (All versions < V19 Update 4), SIMOCODE ES V16 (All versions), SIMOCODE ES V17 (All versions), SIMOCODE ES V18 (All versions), SIMOCODE ES V19 (All versions), SIMOTION SCOUT TIA V5.4 (All versions < V17 Update 9), SIMOTION SCOUT TIA V5.5 (All versions < V18 Update 6), SIMOTION SCOUT TIA V5.6 (All versions < V19 Update 4), SINAMICS Startdrive V16 (All versions), SINAMICS Startdrive V17 (All versions), SINAMICS Startdrive V18 (All versions), SINAMICS Startdrive V19 (All versions), SIRIUS Safety ES V17 (TIA Portal) (All versions), SIRIUS Safety ES V18 (TIA Portal) (All versions < V18 Update 6), SIRIUS Safety ES V19 (TIA Portal) (All versions), SIRIUS Soft Starter ES V17 (TIA Portal) (All versions), SIRIUS Soft Starter ES V18 (TIA Portal) (All versions), SIRIUS Soft Starter ES V19 (TIA Portal) (All versions), TIA Portal Cloud V16 (All versions), TIA Portal Cloud V17 (All versions < V6.0.0.0), TIA Portal Cloud V18 (All versions < V6.3.0.2), TIA Portal Cloud V19 (All versions < V5.2.1.1). Affected products do not properly sanitize user-controllable input when parsing log files. This could allow an attacker to cause a type confusion and execute arbitrary code within the affected application. | ||||
| CVE-2026-12574 | 1 Zohocorp | 1 Ddi Central | 2026-11-10 | 8.1 High |
| Zoho Corporation ManageEngine DDI Central versions 6200 and below are vulnerable to Server-side HTML/JavaScript injection in analytics PDF generation leading to local file disclosure. | ||||
| CVE-2026-12573 | 1 Zohocorp | 1 Ddi Central | 2026-11-10 | 8.8 High |
| Zoho Corporation ManageEngine DDI Central versions 6200 and below are vulnerable to Cisco IOS command injection via DHCP pool name leading to arbitrary commands on managed Cisco routers. | ||||
| CVE-2026-125715 | 2026-11-10 | 5.3 Medium | ||
| Samsung mTower lacks access control for TA sessions, allowing a Normal World application to open TA sessions and invoke their commands, or use a close existing sessions if thier identifiers are known, The impact depends on the affected TA. | ||||
| CVE-2026-123717 | 2026-11-10 | N/A | ||
| OS command injection in the pass and bitwarden credential providers in Eclipse Foundation Eclipse Otterdog through 1.7.1 allows a user able to modify an organization configuration to execute arbitrary commands with the privileges of the operator running otterdog, including access to their credential vault, via a crafted secret reference (pass:<path> or bitwarden:<item>@<field>) or credential identifier that is resolved when otterdog apply is run. | ||||
| CVE-2026-12572 | 1 Zohocorp | 1 Ddi Central | 2026-11-10 | 7.2 High |
| Zoho Corporation ManageEngine DDI Central version below 6201 is vulnerable to SQL injection in HA replication username handling leading to command execution as the PostgreSQL service account. | ||||
| CVE-2026-95651 | 1 Zohocorp | 1 Ddi Central | 2026-11-10 | 7.5 High |
| Zoho Corporation ManageEngine DDI Central versions 6500 and below are vulnerable to an unauthenticated GSS-TSIG keytab update vulnerability in the Linux Node Agent. | ||||
| CVE-2026-95646 | 1 Zohocorp | 1 Ddi Central | 2026-11-10 | 8 High |
| Zoho Corporation ManageEngine DDI Central versions 6500 and below are vulnerable to a Unicode-based command injection vulnerability in the Cisco IOS DHCP configuration functionality. This vulnerability could allow cluster-scoped operators to inject specially crafted Unicode characters, resulting in the execution of unintended device commands. | ||||
| CVE-2026-119446 | 1 Nerves-hub | 1 Nerves Hub Web | 2026-11-10 | N/A |
| Session Fixation vulnerability in the CLI login flow in nerves-hub nerves_hub_web allows an unauthenticated attacker to obtain an API token for another user's account via a crafted login link. Starting a CLI login with POST /api/auth/cli_session needs no authentication and returns a polling token, a confirmation URL that carries that token, and a confirmation code. When a signed-in user opens that URL and clicks Confirm, NervesHub.Accounts.verify_cli_session_token/2 creates an API token for the user's account and stores it on the login, and the next poll of GET /api/auth/cli_session/<token> returns it to whoever started the login. The confirmation code is only displayed and is never compared with anything, so it cannot show that the person confirming is the one who started the login. The confirm form carries a CSRF token and the page cannot be framed, so the attacker has to persuade the user to open the link and click the button themselves. This issue affects nerves_hub: from 2.5.0 before 2.5.3. | ||||
| CVE-2026-120286 | 1 Nerves-hub | 1 Nerves Hub Web | 2026-11-10 | N/A |
| Missing Authorization vulnerability in the device and deployment group pages in nerves-hub nerves_hub_web allows an authenticated organization member with the view role to change devices and deployment groups via LiveView events reserved for the manage role. The event handlers that add and delete device certificates, add and remove tags, overwrite or clear a device's manual location, remove a device from its deployment group, move matched devices into a deployment group or remove unmatched ones, import devices from a CSV, and start, retry or delete firmware delta builds carry out the change without calling authorized!/2, and the pages render the controls to every member. A view member can add a certificate that lets whoever holds its key connect as the device, delete a certificate so the device can no longer authenticate with it, and change which deployment group, and so which firmware release, a device receives. Everything stays within the organizations the member belongs to. This issue affects nerves_hub: from 1.0.0 before 2.5.3. | ||||