| CVE-2025-1863 | 2026-04-15 | 9.8 Critical | ||
| Insecure default settings have been found in recorder products provided by Yokogawa Electric Corporation. The default setting of the authentication function is disabled on the affected products. Therefore, when connected to a network with default settings, anyone can access all functions related to settings and operations. As a result, an attacker can illegally manipulate and configure important data such as measured values and settings. This issue affects GX10 / GX20 / GP10 / GP20 Paperless Recorders: R5.04.01 or earlier; GM Data Acquisition System: R5.05.01 or earlier; DX1000 / DX2000 / DX1000N Paperless Recorders: R4.21 or earlier; FX1000 Paperless Recorders: R1.31 or earlier; μR10000 / μR20000 Chart Recorders: R1.51 or earlier; MW100 Data Acquisition Units: All versions; DX1000T / DX2000T Paperless Recorders: All versions; CX1000 / CX2000 Paperless Recorders: All versions. | ||||
| CVE-2025-24288 | 1 Versa | 1 Director | 2026-04-15 | 9.8 Critical |
| The Versa Director software exposes a number of services by default and allow attackers an easy foothold due to default credentials and multiple accounts (most with sudo access) that utilize the same default credentials. By default, Versa director exposes ssh and postgres to the internet, alongside a host of other services. Versa Networks is not aware of any reported instance where this vulnerability was exploited. Proof of concept for this vulnerability has been disclosed by third party security researchers. Workarounds or Mitigation: Versa recommends the following security controls: 1) Change default passwords to complex passwords 2) Passwords must be complex with at least 8 characters that comprise of upper case, and lower case alphabets, as well as at at least one digit, and one special character 3) Passwords must be changed at least every 90 days 4) Password change history is checked to ensure that the at least the last 5 passwords must be used when changing password. 5) Review and audit logs for all authentication attempts to check for unauthorized/suspicious login attempts and enforce remediation steps. | ||||
| CVE-2025-11085 | 1 Rockwellautomation | 1 Factorytalk | 2026-04-15 | N/A |
| A security issue exists within DataMosaix™ Private Cloud allowing for Persistent XSS. This vulnerability can result in the execution of malicious JavaScript, allowing for account takeover, credential theft, or redirection to a malicious website. | ||||
| CVE-2025-8760 | 2026-04-15 | 9.8 Critical | ||
| A vulnerability was identified in INSTAR 2K+ and 4K 3.11.1 Build 1124. This affects the function base64_decode of the component fcgi_server. The manipulation of the argument Authorization leads to buffer overflow. It is possible to initiate the attack remotely. | ||||
| CVE-2025-31930 | 2026-04-15 | 8.8 High | ||
| A vulnerability has been identified in IEC 1Ph 7.4kW Child socket (8EM1310-2EH04-0GA0) (All versions < V2.135), IEC 1Ph 7.4kW Child socket/ shutter (8EM1310-2EN04-0GA0) (All versions < V2.135), IEC 1Ph 7.4kW Parent cable 7m (8EM1310-2EJ04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent cable 7m incl. SIM (8EM1310-2EJ04-3GA2) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket (8EM1310-2EH04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket incl. SIM (8EM1310-2EH04-3GA2) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket/ shutter (8EM1310-2EN04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket/ shutter SIM (8EM1310-2EN04-3GA2) (All versions < V2.135), IEC 3Ph 22kW Child cable 7m (8EM1310-3EJ04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Child socket (8EM1310-3EH04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Child socket/ shutter (8EM1310-3EN04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Parent cable 7m (8EM1310-3EJ04-3GA1) (All versions < V2.135), IEC 3Ph 22kW Parent cable 7m incl. SIM (8EM1310-3EJ04-3GA2) (All versions < V2.135), IEC 3Ph 22kW Parent socket (8EM1310-3EH04-3GA1) (All versions < V2.135), IEC 3Ph 22kW Parent socket incl. SIM (8EM1310-3EH04-3GA2) (All versions < V2.135), IEC 3Ph 22kW Parent socket/ shutter (8EM1310-3EN04-3GA1) (All versions < V2.135), IEC 3Ph 22kW Parent socket/ shutter SIM (8EM1310-3EN04-3GA2) (All versions < V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA0) (All versions < V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA1) (All versions < V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA2) (All versions < V2.135), IEC ERK 3Ph 22 kW Child socket (8EM1310-3FH04-0GA0) (All versions < V2.135), IEC ERK 3Ph 22 kW Parent socket (8EM1310-3FH04-3GA1) (All versions < V2.135), IEC ERK 3Ph 22 kW Parent socket incl. SI (8EM1310-3FH04-3GA2) (All versions < V2.135), UL Commercial Cellular 48A NTEP (8EM1310-5HF14-1GA2) (All versions < V2.135), UL Commercial Child 40A w/ 15118 HW (8EM1310-4CF14-0GA0) (All versions < V2.135), UL Commercial Child 48A BA Compliant (8EM1315-5CG14-0GA0) (All versions < V2.135), UL Commercial Child 48A w/ 15118 HW (8EM1310-5CF14-0GA0) (All versions < V2.135), UL Commercial Parent 40A with Simcard (8EM1310-4CF14-1GA2) (All versions < V2.135), UL Commercial Parent 48A (USPS) (8EM1317-5CG14-1GA2) (All versions < V2.135), UL Commercial Parent 48A BA Compliant (8EM1315-5CG14-1GA2) (All versions < V2.135), UL Commercial Parent 48A with Simcard BA (8EM1310-5CF14-1GA2) (All versions < V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1310-5CG14-1GA1) (All versions < V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1314-5CG14-2FA2) (All versions < V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1315-5HG14-1GA2) (All versions < V2.135), UL Commercial Parent 48A,15118 25ft Sim (8EM1310-5CG14-1GA2) (All versions < V2.135), VersiCharge Blue™ 80A AC Cellular (8EM1315-7BG16-1FH2) (All versions < V2.135). Affected devices contain Modbus service enabled by default. This could allow an attacker connected to the same network to remotely control the EV charger. | ||||
| CVE-2025-5555 | 1 Dieboldnixdorf | 1 Wincor | 2026-04-15 | 7.8 High |
| A vulnerability has been found in Nixdorf Wincor PORT IO Driver up to 1.0.0.1. This affects the function sub_11100 in the library wnport.sys of the component IOCTL Handler. Such manipulation leads to stack-based buffer overflow. Local access is required to approach this attack. The exploit has been disclosed to the public and may be used. Upgrading to version 3.0.0.1 is able to mitigate this issue. Upgrading the affected component is recommended. The vendor was contacted beforehand and was able to provide a patch very early. | ||||
| CVE-2025-59936 | 1 Nearform | 1 Get-jwks | 2026-04-15 | N/A |
| get-jwks contains fetch utils for JWKS keys. In versions prior to 11.0.2, a vulnerability in get-jwks can lead to cache poisoning in the JWKS key-fetching mechanism. When the iss (issuer) claim is validated only after keys are retrieved from the cache, it is possible for cached keys from an unexpected issuer to be reused, resulting in a bypass of issuer validation. This design flaw enables a potential attack where a malicious actor crafts a pair of JWTs, the first one ensuring that a chosen public key is fetched and stored in the shared JWKS cache, and the second one leveraging that cached key to pass signature validation for a targeted iss value. The vulnerability will work only if the iss validation is done after the use of get-jwks for keys retrieval. This issue has been patched in version 11.0.2. | ||||
| CVE-2024-27629 | 1 Rordenlab | 1 Dcm2niix | 2026-04-15 | 7.8 High |
| An issue in dc2niix before v.1.0.20240202 allows a local attacker to execute arbitrary code via the generated file name is not properly escaped and injected into a system call when certain types of compression are used. | ||||
| CVE-2025-57564 | 1 Cubeapm | 1 Cubeapm | 2026-04-15 | 8.2 High |
| CubeAPM nightly-2025-08-01-1 allow unauthenticated attackers to inject arbitrary log entries into production systems via the /api/logs/insert/elasticsearch/_bulk endpoint. This endpoint accepts bulk log data without requiring authentication or input validation, allowing remote attackers to perform unauthorized log injection. Exploitation may lead to false log entries, log poisoning, alert obfuscation, and potential performance degradation of the observability pipeline. The issue is present in the core CubeAPM platform and is not limited to specific deployment configurations. | ||||
| CVE-2025-46333 | 2026-04-15 | N/A | ||
| z2d is a pure Zig 2D graphics library. Versions of z2d after `0.5.1` and up to and including `0.6.0`, when writing from one surface to another using `z2d.compositor.StrideCompositor.run`, and higher-level operations when the anti-aliasing mode is set to `.default` (such as `Context.fill`, `Context.stroke`, `painter.fill`, and `painter.stroke`), the source surface can be completely out-of-bounds on the x-axis, but not on the y-axis, by way of a negative offset. This results in an overflow of the value controlling the length of the stride. In non-safe optimization modes (consumers compiling with `ReleaseFast` or `ReleaseSmall`), this could potentially lead to invalid memory accesses or corruption. This issue is patched in version `0.6.1`. Users on an untagged version after `v0.5.1` and before `v0.6.1` are advised to update to address the vulnerability. Those still on Zig `0.13.0` are recommended to downgrade to `v0.5.1`. | ||||
| CVE-2024-22041 | 1 Siemens | 13 Cerberus Pro En Engineering Tool, Cerberus Pro En Fire Panel Fc72x, Cerberus Pro En X200 Cloud Distribution and 10 more | 2026-04-15 | 7.5 High |
| A vulnerability has been identified in Cerberus PRO EN Engineering Tool (All versions), Cerberus PRO EN Fire Panel FC72x IP6 (All versions), Cerberus PRO EN Fire Panel FC72x IP7 (All versions), Cerberus PRO EN Fire Panel FC72x IP8 (All versions < IP8 SR4), Cerberus PRO EN X200 Cloud Distribution IP7 (All versions), Cerberus PRO EN X200 Cloud Distribution IP8 (All versions < V4.3.5618), Cerberus PRO EN X300 Cloud Distribution IP7 (All versions), Cerberus PRO EN X300 Cloud Distribution IP8 (All versions < V4.3.5617), Cerberus PRO UL Compact Panel FC922/924 (All versions < MP4), Cerberus PRO UL Engineering Tool (All versions < MP4), Cerberus PRO UL X300 Cloud Distribution (All versions < V4.3.0001), Desigo Fire Safety UL Compact Panel FC2025/2050 (All versions < MP4), Desigo Fire Safety UL Engineering Tool (All versions < MP4), Desigo Fire Safety UL X300 Cloud Distribution (All versions < V4.3.0001), Sinteso FS20 EN Engineering Tool (All versions), Sinteso FS20 EN Fire Panel FC20 MP6 (All versions), Sinteso FS20 EN Fire Panel FC20 MP7 (All versions), Sinteso FS20 EN Fire Panel FC20 MP8 (All versions < MP8 SR4), Sinteso FS20 EN X200 Cloud Distribution MP7 (All versions), Sinteso FS20 EN X200 Cloud Distribution MP8 (All versions < V4.3.5618), Sinteso FS20 EN X300 Cloud Distribution MP7 (All versions), Sinteso FS20 EN X300 Cloud Distribution MP8 (All versions < V4.3.5617), Sinteso Mobile (All versions). The network communication library in affected systems improperly handles memory buffers when parsing X.509 certificates. This could allow an unauthenticated remote attacker to crash the network service. | ||||
| CVE-2025-40927 | 2026-04-15 | 7.3 High | ||
| CGI::Simple versions before 1.282 for Perl has a HTTP response splitting flaw This vulnerability is a confirmed HTTP response splitting flaw in CGI::Simple that allows HTTP response header injection, which can be used for reflected XSS or open redirect under certain conditions. Although some validation exists, it can be bypassed using URL-encoded values, allowing an attacker to inject untrusted content into the response via query parameters. As a result, an attacker can inject a line break (e.g. %0A) into the parameter value, causing the server to split the HTTP response and inject arbitrary headers or even an HTML/JavaScript body, leading to reflected cross-site scripting (XSS), open redirect or other attacks. The issue documented in CVE-2010-4410 https://www.cve.org/CVERecord?id=CVE-2010-4410 is related but the fix was incomplete. Impact By injecting %0A (newline) into a query string parameter, an attacker can: * Break the current HTTP header * Inject a new header or entire body * Deliver a script payload that is reflected in the server’s response That can lead to the following attacks: * reflected XSS * open redirect * cache poisoning * header manipulation | ||||
| CVE-2025-2401 | 2026-04-15 | N/A | ||
| Buffer overflow vulnerability in Immunity Debugger affecting version 1.85, its exploitation could allow a local attacker to execute arbitrary code, due to the lack of proper boundary checking. | ||||
| CVE-2025-3007 | 2026-04-15 | 5.5 Medium | ||
| A vulnerability was found in Novastar CX40 up to 2.44.0. It has been rated as critical. This issue affects the function getopt of the file /usr/nova/bin/netconfig of the component NetFilter Utility. The manipulation of the argument cmd/netmask/pipeout/nettask leads to stack-based buffer overflow. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. | ||||
| CVE-2024-46547 | 2026-04-15 | 7.5 High | ||
| A vulnerability was found in Romain Bourdon Wampserver all versions (discovered in v3.2.3 and v3.2.6) where unauthorized users could access sensitive information due to improper access control validation via PHP Info Page. This issue can lead to data leaks. | ||||
| CVE-2024-36434 | 1 Supermicro | 3 X11dph-i, X11dph-t, X11dph-tq | 2026-04-15 | 7.5 High |
| An SMM callout vulnerability was discovered in Supermicro X11DPH-T, X11DPH-Tq, and X11DPH-i motherboards with BIOS firmware before 4.4. | ||||
| CVE-2025-11537 | 1 Redhat | 2 Build Keycloak, Build Of Keycloak | 2026-04-15 | 5 Medium |
| A flaw was found in Keycloak. When the logging format is configured to a verbose, user-supplied pattern (such as the pre-defined 'long' pattern), sensitive headers including Authorization and Cookie are disclosed to the logs in cleartext. An attacker with read access to the log files can extract these credentials (e.g., bearer tokens, session cookies) and use them to impersonate users, leading to a full account compromise. | ||||
| CVE-2025-46599 | 1 K3s | 1 K3s | 2026-04-15 | 6.8 Medium |
| CNCF K3s 1.32 before 1.32.4-rc1+k3s1 has a Kubernetes kubelet configuration change with the unintended consequence that, in some situations, ReadOnlyPort is set to 10255. For example, the default behavior of a K3s online installation might allow unauthenticated access to this port, exposing credentials. | ||||
| CVE-2025-53602 | 2026-04-15 | 5.3 Medium | ||
| Zipkin through 3.5.1 has a /heapdump endpoint (associated with the use of Spring Boot Actuator), a similar issue to CVE-2025-48927. | ||||
| CVE-2024-28815 | 1 Mitel | 2 Cmg Suite, Inattend | 2026-04-15 | 9.8 Critical |
| A vulnerability in the BluStar component of Mitel InAttend 2.6 SP4 through 2.7 and CMG 8.5 SP4 through 8.6 could allow access to sensitive information, changes to the system configuration, or execution of arbitrary commands within the context of the system. | ||||