Philips Hue Bridge HomeKit hk_hap_pair_storage_put Heap-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Philips Hue Bridge. Authentication is not required to exploit this vulnerability.
The specific flaw exists within the hk_hap_pair_storage_put function of the HomeKit implementation, which listens on TCP port 8080 by default. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a heap-based buffer. An attacker can leverage this vulnerability to execute code in the context of the device. Was ZDI-CAN-28469.
Metrics
Affected Vendors & Products
References
| Link | Providers |
|---|---|
| https://www.zerodayinitiative.com/advisories/ZDI-26-158/ |
|
History
Fri, 13 Mar 2026 21:00:00 +0000
| Type | Values Removed | Values Added |
|---|---|---|
| Description | Philips Hue Bridge HomeKit hk_hap_pair_storage_put Heap-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Philips Hue Bridge. Authentication is not required to exploit this vulnerability. The specific flaw exists within the hk_hap_pair_storage_put function of the HomeKit implementation, which listens on TCP port 8080 by default. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a heap-based buffer. An attacker can leverage this vulnerability to execute code in the context of the device. Was ZDI-CAN-28469. | |
| Title | Philips Hue Bridge HomeKit hk_hap_pair_storage_put Heap-based Buffer Overflow Remote Code Execution Vulnerability | |
| Weaknesses | CWE-122 | |
| References |
| |
| Metrics |
cvssV3_0
|
Status: PUBLISHED
Assigner: zdi
Published:
Updated: 2026-03-13T20:37:01.412Z
Reserved: 2026-03-04T19:42:49.491Z
Link: CVE-2026-3560