Search Results (11 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2026-4526 1 Silicon Labs 1 Emberznet 2026-06-26 N/A
In EmberZNet v9.0.2 and earlier, malformed global ZCL messages can trigger out-of-bounds reads in framework parsing logic and terminate the process. These messages must come from a device that has already joined the network, and no information leakage back to the sender was observed.
CVE-2026-47145 1 Silicon Labs 1 Emberznet 2026-06-26 N/A
In EmberZNet v9.0.2 and earlier, malformed Color Control messages can lead to asserts that terminate the process. These messages must come from a device that has already joined the network. Only devices supporting the Color Control cluster may be impacted.
CVE-2026-47146 1 Silicon Labs 1 Emberznet 2026-06-26 N/A
In EmberZNet v9.0.2 and earlier, malformed Color Control messages can lead to asserts that terminate the process. These messages must come from a device that has already joined the network. Only devices supporting the Color Control cluster may be impacted.
CVE-2026-47147 1 Silicon Labs 1 Emberznet 2026-06-26 N/A
In EmberZNet v9.0.2 and earlier, malformed OTA requests can drive the OTA server parser into out-of-bounds reads. A limited amount of data from RAM is read back to the requester. The size and location of this data is limited. These requests must come from a device that has already joined the network. Only devices supporting the OTA Server cluster may be impacted.
CVE-2026-47148 1 Silicon Labs 1 Emberznet 2026-06-26 N/A
In EmberZNet v9.0.2 and earlier, malformed GetGroupMembership commands can trigger repeated reads past the end of the message payload and terminate the process. These messages must come from a device that has already joined the network, and no information leakage back to the sender was observed. Only devices supporting the Groups cluster may be impacted.
CVE-2026-47149 1 Silicon Labs 1 Emberznet 2026-06-26 N/A
In EmberZNet v9.0.2 and earlier, malformed or out-of-range Door Lock user identifiers can trigger out-of-bounds table reads and terminate the process. These messages must come from a device that has already joined the network, and no information leakage back to the sender was observed. Only devices supporting the Door Lock cluster may be impacted.
CVE-2026-47150 1 Silicon Labs 1 Emberznet 2026-06-26 N/A
In EmberZNet v9.0.2 and earlier, malformed IAS Zone enrollment messages can trigger an out-of-bounds state-table write and terminate the process. The size and location of this write is limited. These messages must come from a device that has already joined the network. Only devices supporting the IAS Zone cluster may be impacted.
CVE-2026-47151 1 Silicon Labs 1 Emberznet 2026-06-26 N/A
In EmberZNet v9.0.2 and earlier, malformed ClearWeekdaySchedule messages can trigger out-of-bounds writes into Door Lock schedule state. The size and location of this data is limited. These messages must come from a device that has already joined the network. Only devices supporting the Door Lock cluster may be impacted.
CVE-2026-47152 1 Silicon Labs 1 Emberznet 2026-06-26 N/A
In EmberZNet v9.0.2 and earlier, a malformed Level Control Move command can terminate the process through a divide-by-zero fault. This command must come from a device that has already joined the network. Only devices supporting the Level Control cluster may be impacted.
CVE-2026-47153 1 Silicon Labs 1 Emberznet 2026-06-26 N/A
In EmberZNet v9.0.2 and earlier, a malformed Level Control Step command can terminate the process through a divide-by-zero fault. This command must come from a device that has already joined the network. Only devices supporting the Level Control cluster may be impacted.
CVE-2026-47154 1 Silicon Labs 1 Emberznet 2026-06-26 N/A
In EmberZNet v9.0.2 and earlier, a malformed GetProfileResponse message can trigger out-of-bounds reads while iterating interval entries and terminate the process. These messages must come from a device that has already joined the network, and no information leakage back to the sender was observed. Only devices supporting the Simple Metering cluster may be impacted.