Search Results (921 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2025-10641 1 Efficientlab 1 Workexaminer Professional 2026-04-15 7.1 High
All WorkExaminer Professional traffic between monitoring client, console and server is transmitted as plain text. This allows an attacker with access to the network to read the transmitted sensitive data. An attacker can also freely modify the data on the wire. The monitoring clients transmit their data to the server using the unencrypted FTP. Clients connect to the FTP server on port 12304 and transmit the data unencrypted. In addition, all traffic between the console client and the server at port 12306 is unencrypted.
CVE-2025-41718 1 Murrelektronik 4 Firmware Impact67 Pro 54620, Firmware Impact67 Pro 54630, Firmware Impact67 Pro 54631 and 1 more 2026-04-15 7.5 High
A cleartext transmission of sensitive information vulnerability in the affected products allows an unauthorized remote attacker to gain login credentials and access the Web-UI.
CVE-2025-2818 2026-04-15 3.5 Low
A vulnerability was reported in version 1.0 of the Bluetooth Transmission Alliance protocol adopted by Motorola Smart Connect Android Application that could allow a nearby attacker within the Bluetooth interaction range to intercept files when transferred to a device not paired in Smart Connect.
CVE-2024-45361 2 Mi, Xiaomi 2 Xiaomi, Mi Connect Service 2026-04-15 6.5 Medium
A protocol flaw vulnerability exists in the Xiaomi Mi Connect Service APP. The vulnerability is caused by the validation logic is flawed and can be exploited by attackers to leak sensitive user information.
CVE-2024-36558 2026-04-15 7.5 High
Forever KidsWatch Call Me KW-50 R36_YDR_A3PW_GM7S_V1.0_2019_07_15_16.19.24_cob_h suffers from Cleartext Transmission of Sensitive Information due to lack of encryption in device-server communication.
CVE-2024-28169 2026-04-15 5.4 Medium
Cleartext transmission of sensitive information for some BigDL software maintained by Intel(R) before version 2.5.0 may allow an authenticated user to potentially enable denial of service via adjacent access.
CVE-2020-36914 1 Qihang Media 1 Web Digital Signage 2026-04-15 7.5 High
QiHang Media Web Digital Signage 3.0.9 contains a sensitive information disclosure vulnerability that allows remote attackers to intercept user authentication credentials through cleartext cookie transmission. Attackers can perform man-in-the-middle attacks to capture and potentially misuse stored authentication credentials transmitted in an insecure manner.
CVE-2024-1657 1 Redhat 3 Ansible Automation Platform, Ansible Automation Platform Developer, Ansible Automation Platform Inside 2026-04-15 8.1 High
A flaw was found in the ansible automation platform. An insecure WebSocket connection was being used in installation from the Ansible rulebook EDA server. An attacker that has access to any machine in the CIDR block could download all rulebook data from the WebSocket, resulting in loss of confidentiality and integrity of the system.
CVE-2024-35495 2026-04-15 4.3 Medium
An Information Disclosure vulnerability in the Telemetry component in TP-Link Kasa KP125M V1.0.0 and Tapo P125M 1.0.0 Build 220930 Rel.143947 allows attackers to observe device state via observing network traffic.
CVE-2024-48788 1 Yescam 1 Yescam Firmware 2026-04-15 7.5 High
An issue in YESCAM (com.yescom.YesCam.zwave) 1.0.2 allows a remote attacker to obtain sensitive information via the firmware update process.
CVE-2024-41124 2026-04-15 6.3 Medium
Puncia is the Official CLI utility for Subdomain Center & Exploit Observer. `API_URLS` is utilizing HTTP instead of HTTPS for communication that can lead to issues like Eavesdropping, Data Tampering, Unauthorized Data Access & MITM Attacks. This issue has been addressed in release version 0.21 by using https rather than http connections. All users are advised to upgrade. There is no known workarounds for this vulnerability.
CVE-2017-20200 2026-04-15 3.7 Low
A vulnerability has been found in Coinomi up to 1.7.6. This issue affects some unknown processing. Such manipulation leads to cleartext transmission of sensitive information. The attack can be launched remotely. This attack is characterized by high complexity. The exploitability is assessed as difficult. The exploit has been disclosed to the public and may be used. The vendor replied with: "(...) there isn't any security implication associated with your findings."
CVE-2025-61481 1 Mikrotik 2 Routeros, Switchos 2026-04-15 10 Critical
An issue in MikroTik RouterOS v.7.14.2 and SwOS v.2.18 exposes the WebFig management interface over cleartext HTTP by default, allowing an on-path attacker to execute injected JavaScript in the administrator’s browser and intercept credentials.
CVE-2022-32510 1 Nuki 1 Bridge 2026-04-15 7.1 High
An issue was discovered on certain Nuki Home Solutions devices. The HTTP API exposed by a Bridge used an unencrypted channel to provide an administrative interface. A token can be easily eavesdropped by a malicious actor to impersonate a legitimate user and gain access to the full set of API endpoints. This affects Nuki Bridge v1 before 1.22.0 and v2 before 2.13.2.
CVE-2024-12378 2026-04-15 9.1 Critical
On affected platforms running Arista EOS with secure Vxlan configured, restarting the Tunnelsec agent will result in packets being sent over the secure Vxlan tunnels in the clear.
CVE-2024-40595 1 Oneidentity 1 Safeguard For Privileged Sessions 2026-04-15 5.3 Medium
An authentication-bypass issue in the RDP component of One Identity Safeguard for Privileged Sessions (SPS) On Premise before 7.5.1 (and LTS before 7.0.5.1) allows man-in-the-middle attackers to obtain access to privileged sessions on target resources by intercepting cleartext RDP protocol information.
CVE-2026-23662 1 Microsoft 1 Azure Iot Explorer 2026-04-14 7.5 High
Missing authentication for critical function in Azure IoT Explorer allows an unauthorized attacker to disclose information over a network.
CVE-2026-23661 1 Microsoft 1 Azure Iot Explorer 2026-04-14 7.5 High
Cleartext transmission of sensitive information in Azure IoT Explorer allows an unauthorized attacker to disclose information over a network.
CVE-2012-5562 1 Redhat 2 Network Proxy, Satellite 2026-04-09 8.6 High
A flaw was found in rhn-proxy. This vulnerability may allow the rhn-proxy to transmit user credentials in clear-text when it accesses RHN Satellite. This could lead to information disclosure, where sensitive authentication details are exposed to unauthorized parties.
CVE-2026-4820 1 Ibm 1 Maximo Application Suite 2026-04-08 4.3 Medium
IBM Maximo Application Suite 9.1, 9.0, 8.11, and 8.10 does not set the secure attribute on authorization tokens or session cookies. Attackers may be able to get the cookie values by sending a http:// link to a user or by planting this link in a site the user goes to. The cookie will be sent to the insecure link and the attacker can then obtain the cookie value by snooping the traffic.