| A vulnerability has been identified in COMOS V10.6 (All versions < V10.6.1), COMOS V10.6 (All versions < V10.6.1), JT Bi-Directional Translator for STEP (All versions), NX V2412 (All versions < V2412.8900 with Cloud Entitlement (bundled as NX X)), NX V2506 (All versions < V2506.6000 with Cloud Entitlement (bundled as NX X)), Simcenter 3D (All versions < V2506.6000 with Cloud Entitlement (bundled as Simcenter X Mechanical)), Simcenter Femap (All versions < V2506.0002 with Cloud Entitlement (bundled as Simcenter X Mechanical)), Simcenter Studio (All versions < V2506.0001), Simcenter System Architect (All versions < V2506.0001), Tecnomatix Plant Simulation (All versions < V2504.0007). The SALT SDK is missing server certificate validation while establishing TLS connections to the authorization server. This could allow an attacker to perform a man-in-the-middle attack. |
| A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions), RUGGEDCOM ROX MX5000RE (All versions), RUGGEDCOM ROX RX1400 (All versions), RUGGEDCOM ROX RX1500 (All versions), RUGGEDCOM ROX RX1501 (All versions), RUGGEDCOM ROX RX1510 (All versions), RUGGEDCOM ROX RX1511 (All versions), RUGGEDCOM ROX RX1512 (All versions), RUGGEDCOM ROX RX1524 (All versions), RUGGEDCOM ROX RX1536 (All versions), RUGGEDCOM ROX RX5000 (All versions). The affected devices do not properly enforce the restriction of files that can be uploaded from the web interface. This could allow an authenticated remote attacker with high privileges in the web interface to upload arbitrary files. |
| A vulnerability has been identified in POWER METER SICAM Q100 (7KG9501-0AA01-0AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q100 (7KG9501-0AA01-2AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q100 (7KG9501-0AA31-0AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q100 (7KG9501-0AA31-2AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q200 family (All versions >= V2.70 < V2.80). Affected devices store the password for the SMTP account as plain text. This could allow an authenticated local attacker to extract it and use the configured SMTP service for arbitrary purposes. |
| A vulnerability has been identified in SIMATIC S7-PLCSIM V16 (All versions), SIMATIC S7-PLCSIM V17 (All versions), SIMATIC STEP 7 Safety V16 (All versions), SIMATIC STEP 7 Safety V17 (All versions < V17 Update 8), SIMATIC STEP 7 Safety V18 (All versions < V18 Update 5), SIMATIC STEP 7 V16 (All versions), SIMATIC STEP 7 V17 (All versions < V17 Update 8), SIMATIC STEP 7 V18 (All versions < V18 Update 5), SIMATIC WinCC Unified V16 (All versions), SIMATIC WinCC Unified V17 (All versions < V17 Update 8), SIMATIC WinCC Unified V18 (All versions < V18 SP5), SIMATIC WinCC V16 (All versions), SIMATIC WinCC V17 (All versions < V17 Update 8), SIMATIC WinCC V18 (All versions < V18 SP5), SIMOCODE ES V16 (All versions), SIMOCODE ES V17 (All versions < V17 Update 8), SIMOCODE ES V18 (All versions), SIMOTION SCOUT TIA V5.4 SP1 (All versions), SIMOTION SCOUT TIA V5.4 SP3 (All versions), SIMOTION SCOUT TIA V5.5 SP1 (All versions), SINAMICS Startdrive V16 (All versions), SINAMICS Startdrive V17 (All versions), SINAMICS Startdrive V18 (All versions), SIRIUS Safety ES V17 (TIA Portal) (All versions < V17 Update 8), SIRIUS Safety ES V18 (TIA Portal) (All versions), SIRIUS Soft Starter ES V17 (TIA Portal) (All versions < V17 Update 8), SIRIUS Soft Starter ES V18 (TIA Portal) (All versions), TIA Portal Cloud V16 (All versions), TIA Portal Cloud V17 (All versions < V4.6.0.1), TIA Portal Cloud V18 (All versions < V4.6.1.0). Affected products do not properly sanitize user-controllable input when parsing user settings. This could allow an attacker to cause a type confusion and execute arbitrary code within the affected application. |
| A vulnerability has been identified in Tecnomatix Plant Simulation V2302 (All versions < V2302.0011). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted MODEL file. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-22974) |
| A vulnerability has been identified in SCALANCE W1748-1 M12 (6GK5748-1GY01-0AA0), SCALANCE W1748-1 M12 (6GK5748-1GY01-0TA0), SCALANCE W1788-1 M12 (6GK5788-1GY01-0AA0), SCALANCE W1788-2 EEC M12 (6GK5788-2GY01-0TA0), SCALANCE W1788-2 M12 (6GK5788-2GY01-0AA0), SCALANCE W1788-2IA M12 (6GK5788-2HY01-0AA0), SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0), SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0), SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0), SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0), SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0), SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0), SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6), SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0), SCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6), SCALANCE W738-1 M12 (6GK5738-1GY00-0AA0), SCALANCE W738-1 M12 (6GK5738-1GY00-0AB0), SCALANCE W748-1 M12 (6GK5748-1GD00-0AA0), SCALANCE W748-1 M12 (6GK5748-1GD00-0AB0), SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0), SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0), SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0), SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0), SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0), SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0), SCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6), SCALANCE W778-1 M12 (6GK5778-1GY00-0AA0), SCALANCE W778-1 M12 (6GK5778-1GY00-0AB0), SCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0), SCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0), SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0), SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0), SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0), SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0), SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0), SCALANCE W786-2 SFP (6GK5786-2FE00-0AA0), SCALANCE W786-2 SFP (6GK5786-2FE00-0AB0), SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0), SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0), SCALANCE W788-1 M12 (6GK5788-1GD00-0AA0), SCALANCE W788-1 M12 (6GK5788-1GD00-0AB0), SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0), SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0), SCALANCE W788-2 M12 (6GK5788-2GD00-0AA0), SCALANCE W788-2 M12 (6GK5788-2GD00-0AB0), SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0), SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0), SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0), SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0), SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0), SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0), SCALANCE WAM763-1 (6GK5763-1AL00-7DA0), SCALANCE WAM766-1 (EU) (6GK5766-1GE00-7DA0), SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0), SCALANCE WAM766-1 EEC (EU) (6GK5766-1GE00-7TA0), SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0), SCALANCE WUM763-1 (6GK5763-1AL00-3AA0), SCALANCE WUM763-1 (6GK5763-1AL00-3DA0), SCALANCE WUM766-1 (EU) (6GK5766-1GE00-3DA0), SCALANCE WUM766-1 (US) (6GK5766-1GE00-3DB0). This CVE refers to Scenario 2 "Abuse the queue for network disruptions" of CVE-2022-47522.
Affected devices can be tricked into enabling its power-saving mechanisms for a victim client. This could allow a physically proximate attacker to execute disconnection and denial-of-service attacks. |
| A vulnerability has been identified in SIMATIC PCS 7 V9.1 (All versions < V9.1 SP2 UC04), SIMATIC WinCC Runtime Professional V17 (All versions < V17 Update 8), SIMATIC WinCC Runtime Professional V18 (All versions < V18 Update 4), SIMATIC WinCC Runtime Professional V19 (All versions < V19 Update 1), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 16), SIMATIC WinCC V8.0 (All versions < V8.0 Update 5). The affected products do not properly validate the input provided in the login dialog box. An attacker could leverage this vulnerability to cause a persistent denial of service condition. |
| A vulnerability has been identified in Cerberus PRO EN Engineering Tool (All versions), Cerberus PRO EN Fire Panel FC72x IP6 (All versions), Cerberus PRO EN Fire Panel FC72x IP7 (All versions), Cerberus PRO EN Fire Panel FC72x IP8 (All versions < IP8 SR4), Cerberus PRO EN X200 Cloud Distribution IP7 (All versions), Cerberus PRO EN X200 Cloud Distribution IP8 (All versions < V4.3.5618), Cerberus PRO EN X300 Cloud Distribution IP7 (All versions), Cerberus PRO EN X300 Cloud Distribution IP8 (All versions < V4.3.5617), Cerberus PRO UL Compact Panel FC922/924 (All versions < MP4), Cerberus PRO UL Engineering Tool (All versions < MP4), Cerberus PRO UL X300 Cloud Distribution (All versions < V4.3.0001), Desigo Fire Safety UL Compact Panel FC2025/2050 (All versions < MP4), Desigo Fire Safety UL Engineering Tool (All versions < MP4), Desigo Fire Safety UL X300 Cloud Distribution (All versions < V4.3.0001), Sinteso FS20 EN Engineering Tool (All versions), Sinteso FS20 EN Fire Panel FC20 MP6 (All versions), Sinteso FS20 EN Fire Panel FC20 MP7 (All versions), Sinteso FS20 EN Fire Panel FC20 MP8 (All versions < MP8 SR4), Sinteso FS20 EN X200 Cloud Distribution MP7 (All versions), Sinteso FS20 EN X200 Cloud Distribution MP8 (All versions < V4.3.5618), Sinteso FS20 EN X300 Cloud Distribution MP7 (All versions), Sinteso FS20 EN X300 Cloud Distribution MP8 (All versions < V4.3.5617), Sinteso Mobile (All versions). The network communication library in affected systems improperly handles memory buffers when parsing X.509 certificates.
This could allow an unauthenticated remote attacker to crash the network service. |
| A vulnerability has been identified in Opcenter Quality (All versions < V2406), Opcenter RDnL (All versions < V2410), SIMATIC PCS neo V4.0 (All versions), SIMATIC PCS neo V4.1 (All versions < V4.1 Update 2), SIMATIC PCS neo V5.0 (All versions < V5.0 Update 1), SINEC NMS (All versions), SINEMA Remote Connect Client (All versions < V3.2 SP3), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 5), Totally Integrated Automation Portal (TIA Portal) V19 (All versions < V19 Update 3). Affected products contain a heap-based buffer overflow vulnerability in the integrated UMC component. This could allow an unauthenticated remote attacker to execute arbitrary code. |
| A vulnerability has been identified in syngo.plaza VB30E (All versions < VB30E_HF07). The affected application does not encrypt the passwords properly.
This could allow an attacker to recover the original passwords and might gain unauthorized access. |
| A vulnerability has been identified in RUGGEDCOM RMC8388 V5.X (All versions < V5.10.1), RUGGEDCOM RS416Pv2 V5.X (All versions < V5.10.1), RUGGEDCOM RS416v2 V5.X (All versions < V5.10.1), RUGGEDCOM RS900 (32M) V5.X (All versions < V5.10.1), RUGGEDCOM RS900G (32M) V5.X (All versions < V5.10.1), RUGGEDCOM RSG2100 (32M) V5.X (All versions < V5.10.1), RUGGEDCOM RSG2100P (32M) V5.X (All versions < V5.10.1), RUGGEDCOM RSG2288 V5.X (All versions < V5.10.1), RUGGEDCOM RSG2300 V5.X (All versions < V5.10.1), RUGGEDCOM RSG2300P V5.X (All versions < V5.10.1), RUGGEDCOM RSG2488 V5.X (All versions < V5.10.1), RUGGEDCOM RSG907R (All versions < V5.10.1), RUGGEDCOM RSG908C (All versions < V5.10.1), RUGGEDCOM RSG909R (All versions < V5.10.1), RUGGEDCOM RSG910C (All versions < V5.10.1), RUGGEDCOM RSG920P V5.X (All versions < V5.10.1), RUGGEDCOM RSL910 (All versions < V5.10.1), RUGGEDCOM RST2228 (All versions < V5.10.1), RUGGEDCOM RST2228P (All versions < V5.10.1), RUGGEDCOM RST916C (All versions < V5.10.1), RUGGEDCOM RST916P (All versions < V5.10.1). Affected devices do not properly validate input during the TLS certificate upload process of the web service. This could allow an authenticated remote attacker to trigger a device crash and reboot, leading to a temporary Denial of Service on the device. |
| A vulnerability has been identified in Simcenter Femap V2306 (All versions), Simcenter Femap V2401 (All versions), Simcenter Femap V2406 (All versions). The affected application is vulnerable to heap-based buffer overflow while parsing specially crafted BDF files. This could allow an attacker to execute code in the context of the current process. |
| A vulnerability has been identified in Tecnomatix Plant Simulation V2302 (All versions < V2302.0012), Tecnomatix Plant Simulation V2404 (All versions < V2404.0001). The affected applications contain a type confusion vulnerability while parsing specially crafted MODEL files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-22958) |
| A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions < V10.0), SIPROTEC 5 6MD85 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 6MD86 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 6MD89 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 6MU85 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7KE85 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7SA82 (CP150) (All versions < V10.0), SIPROTEC 5 7SA86 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7SA87 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7SD82 (CP150) (All versions < V10.0), SIPROTEC 5 7SD86 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7SD87 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7SJ81 (CP150) (All versions < V10.0), SIPROTEC 5 7SJ82 (CP150) (All versions < V10.0), SIPROTEC 5 7SJ85 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7SJ86 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7SK82 (CP150) (All versions < V10.0), SIPROTEC 5 7SK85 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7SL82 (CP150) (All versions < V10.0), SIPROTEC 5 7SL86 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7SL87 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7SS85 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7ST85 (CP300) (All versions < V10.0), SIPROTEC 5 7ST86 (CP300) (All versions < V10.0), SIPROTEC 5 7SX82 (CP150) (All versions < V10.0), SIPROTEC 5 7SX85 (CP300) (All versions < V10.0), SIPROTEC 5 7SY82 (CP150) (All versions < V10.0), SIPROTEC 5 7UM85 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7UT82 (CP150) (All versions < V10.0), SIPROTEC 5 7UT85 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7UT86 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7UT87 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7VE85 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7VK87 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7VU85 (CP300) (All versions < V10.0), SIPROTEC 5 Compact 7SX800 (CP050) (All versions < V10.0). Affected devices do not properly limit the bandwidth for incoming network packets over their local USB port. This could allow an attacker with physical access to send specially crafted packets with high bandwidth to the affected devices thus forcing them to exhaust their memory and stop responding to any network traffic via the local USB port. Affected devices reset themselves automatically after a successful attack. The protection function is not affected of this vulnerability. |
| A vulnerability has been identified in Polarion V2404 (All versions < V2404.5), Polarion V2410 (All versions < V2410.2). The affected application allows arbitrary JavaScript code be included in document titles. This could allow an authenticated remote attacker to conduct a stored cross-site scripting attack by creating specially crafted document titles that are later viewed by other users of the application. |
| A vulnerability has been identified in syngo.plaza VB30E (All versions < VB30E_HF05). The affected application do not properly sanitize input data before sending it to the SQL server. This could allow an attacker with access to the application could use this vulnerability to execute malicious SQL commands to compromise the whole database. |
| A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.16.0), RUGGEDCOM ROX MX5000RE (All versions < V2.16.0), RUGGEDCOM ROX RX1400 (All versions < V2.16.0), RUGGEDCOM ROX RX1500 (All versions < V2.16.0), RUGGEDCOM ROX RX1501 (All versions < V2.16.0), RUGGEDCOM ROX RX1510 (All versions < V2.16.0), RUGGEDCOM ROX RX1511 (All versions < V2.16.0), RUGGEDCOM ROX RX1512 (All versions < V2.16.0), RUGGEDCOM ROX RX1524 (All versions < V2.16.0), RUGGEDCOM ROX RX1536 (All versions < V2.16.0), RUGGEDCOM ROX RX5000 (All versions < V2.16.0). The CLI feature in the web interface of affected devices is vulnerable to
cross-site request forgery (CSRF).
This could allow an attacker to read or modify the device configuration
by tricking an authenticated legitimate user into accessing a malicious link. |
| A vulnerability has been identified in SIMATIC CP 1542SP-1 (6GK7542-6UX00-0XE0) (All versions < V2.4.24), SIMATIC CP 1542SP-1 IRC (6GK7542-6VX00-0XE0) (All versions < V2.4.24), SIMATIC CP 1543SP-1 (6GK7543-6WX00-0XE0) (All versions < V2.4.24), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (6AG2542-6VX00-4XE0) (All versions < V2.4.24), SIPLUS ET 200SP CP 1543SP-1 ISEC (6AG1543-6WX00-7XE0) (All versions < V2.4.24), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (6AG2543-6WX00-4XE0) (All versions < V2.4.24). Affected devices do not properly authenticate configuration connections. This could allow an unauthenticated remote attacker to access the configuration data. |
| A vulnerability has been identified in Mendix Runtime V10 (All versions < V10.17.0 only if the basic authentication mechanism is used by the application), Mendix Runtime V10.12 (All versions < V10.12.11 only if the basic authentication mechanism is used by the application), Mendix Runtime V10.6 (All versions < V10.6.19 only if the basic authentication mechanism is used by the application), Mendix Runtime V8 (All versions < V8.18.33 only if the basic authentication mechanism is used by the application), Mendix Runtime V9 (All versions < V9.24.31 only if the basic authentication mechanism is used by the application). The authentication mechanism of affected applications contains an observable response discrepancy vulnerability when validating usernames. This could allow unauthenticated remote attackers to distinguish between valid and invalid usernames. |
| A vulnerability has been identified in SIMATIC RTLS Locating Manager (6GT2780-0DA00) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA30) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA30) (All versions < V3.0.1.1). The "DBTest" tool of SIMATIC RTLS Locating Manager does not properly enforce access restriction. This could allow an authenticated local attacker to extract sensitive information from memory. |