CVE-2011-3330 1 Schneider-electric 6 Monitor Pro, Opc Factory Server, Pl7 Pro and 3 more 2025-04-11 N/A
Buffer overflow in the UnitelWay Windows Device Driver, as used in Schneider Electric Unity Pro 6 and earlier, OPC Factory Server 3.34, Vijeo Citect 7.20 and earlier, Telemecanique Driver Pack 2.6 and earlier, Monitor Pro 7.6 and earlier, and PL7 Pro 4.5 and earlier, allows local users, and possibly remote attackers, to execute arbitrary code via an unspecified system parameter.
CVE-2012-0931 1 Schneider-electric 1 Modicon Quantum Plc 2025-04-11 9.8 Critical
Schneider Electric Modicon Quantum PLC does not perform authentication between the Unity software and PLC, which allows remote attackers to cause a denial of service or possibly execute arbitrary code via unspecified vectors.
CVE-2012-0930 1 Schneider-electric 1 Modicon Quantum Plc 2025-04-11 6.1 Medium
Cross-site scripting (XSS) vulnerability in Schneider Electric Modicon Quantum PLC allows remote attackers to inject arbitrary web script or HTML via unspecified vectors.
CVE-2012-0929 1 Schneider-electric 1 Modicon Quantum Plc 2025-04-11 7.5 High
Multiple buffer overflows in Schneider Electric Modicon Quantum PLC allow remote attackers to cause a denial of service via malformed requests to the (1) FTP server or (2) HTTP server.
CVE-2011-4035 1 Schneider-electric 3 Citecthistorian, Citectscada Reports, Vijeo Historian 2025-04-11 N/A
Cross-site scripting (XSS) vulnerability in Schneider Electric Vijeo Historian 4.30 and earlier, CitectHistorian 4.30 and earlier, and CitectSCADAReports 4.10 and earlier allows remote attackers to inject arbitrary web script or HTML via unspecified vectors.
CVE-2011-5163 2 Mitsubishi-automation, Schneider-electric 2 Mx4 Scada, Citectscada 2025-04-11 N/A
Buffer overflow in an unspecified third-party component in the Batch module for Schneider Electric CitectSCADA before 7.20 and Mitsubishi MX4 SCADA before 7.20 allows local users to execute arbitrary code via a long string in a login sequence.
CVE-2013-0687 1 Schneider-electric 1 Micom S1 Studio 2025-04-11 N/A
The installer routine in Schneider Electric MiCOM S1 Studio uses world-writable permissions for executable files, which allows local users to modify the service or the configuration files, and consequently gain privileges or trigger incorrect protective-relay operation, via a Trojan horse executable file.
CVE-2011-4034 1 Schneider-electric 3 Citecthistorian, Citectscada Reports, Vijeo Historian 2025-04-11 N/A
Buffer overflow in the Steema TeeChart ActiveX control, as used in Schneider Electric Vijeo Historian 4.30 and earlier, CitectHistorian 4.30 and earlier, and CitectSCADAReports 4.10 and earlier, allows remote attackers to execute arbitrary code or cause a denial of service via unspecified vectors.
CVE-2013-0658 1 Schneider-electric 1 Accutech Manager 2025-04-11 N/A
Heap-based buffer overflow in RFManagerService.exe in Schneider Electric Accutech Manager 2.00.1 and earlier allows remote attackers to execute arbitrary code via a crafted HTTP request.
CVE-2011-3144 2 Aveva, Schneider-electric 3 Clearscada, Scx 67, Scx 68 2025-04-11 N/A
Cross-site scripting (XSS) vulnerability in Control Microsystems ClearSCADA 2005, 2007, and 2009 before R2.3 and R1.4, as used in SCX before 67 R4.5 and 68 R3.9, allows remote attackers to inject arbitrary web script or HTML via unspecified vectors.
CVE-2013-0657 1 Schneider-electric 1 Interactive Graphical Scada System 2025-04-11 N/A
Stack-based buffer overflow in Schneider Electric Interactive Graphical SCADA System (IGSS) 10 and earlier allows remote attackers to execute arbitrary code by sending TCP port-12397 data that does not comply with a protocol.
CVE-2011-4860 1 Schneider-electric 3 Quantum Ethernet Module 140noe77100, Quantum Ethernet Module 140noe77101, Quantum Ethernet Module 140noe77111 2025-04-11 N/A
The ComputePassword function in the Schneider Electric Quantum Ethernet Module on the NOE 771 device (aka the Quantum 140NOE771* module) generates the password for the fwupgrade account by performing a calculation on the MAC address, which makes it easier for remote attackers to obtain access via a (1) ARP request message or (2) Neighbor Solicitation message.
CVE-2011-4861 1 Schneider-electric 3 Quantum Ethernet Module 140noe77100, Quantum Ethernet Module 140noe77101, Quantum Ethernet Module 140noe77111 2025-04-11 N/A
The modbus_125_handler function in the Schneider Electric Quantum Ethernet Module on the NOE 771 device (aka the Quantum 140NOE771* module) allows remote attackers to install arbitrary firmware updates via a MODBUS 125 function code to TCP port 502.
CVE-2011-3143 2 Aveva, Schneider-electric 3 Clearscada, Scx 67, Scx 68 2025-04-11 N/A
Use-after-free vulnerability in Control Microsystems ClearSCADA 2005, 2007, and 2009 before R2.3 and R1.4, as used in SCX before 67 R4.5 and 68 R3.9, allows remote attackers to cause a denial of service (crash) and possibly execute arbitrary code via unspecified long strings that trigger heap memory corruption.
CVE-2013-0664 1 Schneider-electric 3 Modicon M340, Modicon Premium, Modicon Quantum Plc 2025-04-11 N/A
The FactoryCast service on the Schneider Electric Quantum 140NOE77111 and 140NWM10000, M340 BMXNOE0110x, and Premium TSXETY5103 PLC modules allows remote authenticated users to send Modbus messages, and consequently execute arbitrary code, by embedding these messages in SOAP HTTP POST requests.
CVE-2013-2761 1 Schneider-electric 1 Modicon M340 2025-04-11 N/A
The Schneider Electric M340 BMXNOE01xx and BMXP3420xx PLC modules allow remote authenticated users to cause a denial of service (module crash) via crafted FTP traffic, as demonstrated by the FileZilla FTP client.
CVE-2011-4033 1 Schneider-electric 3 Citecthistorian, Citectscada Reports, Vijeo Historian 2025-04-11 N/A
Buffer overflow in the Steema TeeChart ActiveX control, as used in Schneider Electric Vijeo Historian 4.30 and earlier, CitectHistorian 4.30 and earlier, and CitectSCADAReports 4.10 and earlier, allows remote attackers to cause a denial of service via unspecified vectors.
CVE-2013-2782 1 Schneider-electric 2 Tburjr900, Tburjr900 Firmware 2025-04-11 N/A
Schneider Electric Trio J-Series License Free Ethernet Radio with firmware 3.6.0 through 3.6.3 uses the same AES encryption key across different customers' installations, which makes it easier for remote attackers to defeat cryptographic protection mechanisms by leveraging knowledge of this key from another installation.
CVE-2013-3075 2 Mitsubishi-automation, Schneider-electric 3 Mitsubishi Mx Component, Citectfacilities, Citectscada 2025-04-11 N/A
Multiple buffer overflows in ActUWzd.dll 1.0.0.1 in Mitsubishi MX Component 3, as distributed in Citect CitectFacilities 7.10 and CitectScada 7.10r1, allow remote attackers to execute arbitrary code via a long string, as demonstrated by a long WzTitle property value to a certain ActiveX control.
CVE-2013-2824 1 Schneider-electric 4 Citectscada, Powerlogic Scada, Struxureware Powerscada Expert and 1 more 2025-04-11 N/A
Schneider Electric StruxureWare SCADA Expert Vijeo Citect 7.40, Vijeo Citect 7.20 through 7.30SP1, CitectSCADA 7.20 through 7.30SP1, StruxureWare PowerSCADA Expert 7.30 through 7.30SR1, and PowerLogic SCADA 7.20 through 7.20SR1 do not properly handle exceptions, which allows remote attackers to cause a denial of service via a crafted packet.