| Due to missing authentication on a critical function of the devices an unauthenticated remote attacker can execute arbitrary commands, potentially enabling unauthorized upload or download of configuration files and leading to full system compromise. |
| The "serverConfig" endpoint, which returns the module configuration including credentials, is accessible without authentication. |
| Lua apps can be deployed, removed, started, reloaded or stopped without authorization via
AppManager. This allows an attacker to remove legitimate apps creating a DoS attack, read and write
files or load apps that use all features of the product available to a customer. |
| Swissphone DiCal-RED 4009 devices allow a remote attacker to gain a root shell via TELNET without authentication. |
| A client-side remote code execution vulnerability exists in Hanwha Techwin Smart Security Manager (SSM) versions 1.32 and 1.4, due to improper restrictions on the PUT method exposed by the bundled Apache ActiveMQ instance (running on port 8161). An attacker can exploit this flaw through a Cross-Origin Resource Sharing (CORS) bypass combined with JavaScript-triggered file uploads to the web server, ultimately resulting in arbitrary code execution with SYSTEM privileges.
This vulnerability bypasses the server-side mitigations introduced in ZDI-15-156 and ZDI-16-481 by shifting the exploitation to the client-side.
This product is now referred to as Hanwha Wisenet SSM and it is unknown if current versions are affected. |
| Burk Technology ARC Solo's password change mechanism can be utilized without proper
authentication procedures, allowing an attacker to take over the device.
A password change request can be sent directly to the device's HTTP
endpoint without providing valid credentials. The system does not
enforce proper authentication or session validation, allowing the
password change to proceed without verifying the request's legitimacy. |
| Webhood is a self-hosted URL scanner used analyzing phishing and malicious sites. Webhood's backend container images in versions 0.9.0 and earlier are subject to Missing Authentication for Critical Function vulnerability. This vulnerability allows an unauthenticated attacker to send a HTTP request to the database (Pocketbase) admin API to create an admin account. The Pocketbase admin API does not check for authentication/authorization when creating an admin account when no admin accounts have been added. In its default deployment, Webhood does not create a database admin account. Therefore, unless users have manually created an admin account in the database, an admin account will not exist in the deployment and the deployment is vulnerable. Versions starting from 0.9.1 are patched. The patch creates a randomly generated admin account if admin accounts have not already been created i.e. the vulnerability is exploitable in the deployment. As a workaround, users can disable access to URL path starting with `/api/admins` entirely. With this workaround, the vulnerability is not exploitable via network. |
| immich is a high performance self-hosted photo and video management solution. Prior to 1.132.0, immich is vulnerable to account hijacking through oauth2, because the state parameter is not being checked. The oauth2 state parameter is similar to a csrf token, so when the user starts the login flow this unpredictable token is generated and somehow saved in the browser session and passed to the identity provider, which will return the state parameter when redirecting the user back to immich. Before the user is logged in that parameter needs to be verified to make sure the login was actively initiated by the user in this browser session. On it's own, this wouldn't be too bad, but when immich uses the /user-settings page as a redirect_uri, it will automatically link the accounts if the user was already logged in. This means that if someone has an immich instance with a public oauth provider (like google), an attacker can - for example - embed a hidden iframe in a webpage or even just send the victim a forged oauth login url with a code that logs the victim into the attackers oauth account and redirects back to immich and links the accounts. After this, the attacker can log into the victims account using their own oauth credentials. This vulnerability is fixed in 1.132.0. |
| A remote unauthenticated attacker may be able to bypass authentication
by utilizing a specific API route to execute arbitrary OS commands. |
| A remote code execution vulnerability exists in multiple Netcore and Netis routers models with firmware released prior to August 2014 due to the presence of an undocumented backdoor listener on UDP port 53413. Exact version boundaries remain undocumented. An unauthenticated remote attacker can send specially crafted UDP packets to execute arbitrary commands on the affected device. This backdoor uses a hardcoded authentication mechanism and accepts shell commands post-authentication. Some device models include a non-standard implementation of the `echo` command, which may affect exploitability. |
| Toshiba printers provides API without authentication for internal access. A local attacker can bypass authentication in applications, providing administrative access. As for the affected products/models/versions, see the reference URL. |
| Missing Authentication - User & System Configuration |
| Karapace is an open-source implementation of Kafka REST and Schema Registry. Versions 5.0.0 and 5.0.1 contain an authentication bypass vulnerability when configured to use OAuth 2.0 Bearer Token authentication. If a request is sent without an Authorization header, the token validation logic is skipped entirely, allowing an unauthenticated user to read and write to Schema Registry endpoints that should otherwise be protected. This effectively renders the OAuth authentication mechanism ineffective. This issue is fixed in version 5.0.2. |
| A vulnerability was found in eGauge EG3000 Energy Monitor 3.6.3. It has been classified as problematic. This affects an unknown part of the component Setting Handler. The manipulation leads to missing authentication. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. |
| Glutton V1 service endpoints were exposed without any authentication on Gotham stacks, this could have allowed users that did not have any permission to hit glutton backend directly and read/update/delete data. The affected service has been patched and automatically deployed to all Apollo-managed Gotham Instances |
| Missing Authentication for Critical Function vulnerability in Mitsubishi Electric Corporation G-50 all versions, G-50-W all versions, G-50A all versions, GB-50 all versions, GB-50A all versions, GB-24A all versions, G-150AD all versions, AG-150A-A all versions, AG-150A-J all versions, GB-50AD all versions, GB-50ADA-A all versions, GB-50ADA-J all versions, EB-50GU-A all versions, EB-50GU-J all versions, AE-200J all versions, AE-200A all versions, AE-200E all versions, AE-50J all versions, AE-50A all versions, AE-50E all versions, EW-50J all versions, EW-50A all versions, EW-50E all versions, TE-200A all versions, TE-50A all versions, TW-50A all versions, and CMS-RMD-J all versions allows a remote unauthenticated attacker to bypass authentication and then control the air conditioning systems illegally, or disclose information in them by exploiting this vulnerability. In addition, the attacker may tamper with firmware for them using the disclosed information. |
| A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA2) (All versions), LOGO! 12/24RCEo (6ED1052-2MD08-0BA2) (All versions), LOGO! 230RCE (6ED1052-1FB08-0BA2) (All versions), LOGO! 230RCEo (6ED1052-2FB08-0BA2) (All versions), LOGO! 24CE (6ED1052-1CC08-0BA2) (All versions), LOGO! 24CEo (6ED1052-2CC08-0BA2) (All versions), LOGO! 24RCE (6ED1052-1HB08-0BA2) (All versions), LOGO! 24RCEo (6ED1052-2HB08-0BA2) (All versions), SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA2) (All versions), SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA2) (All versions), SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA2) (All versions), SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA2) (All versions), SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA2) (All versions), SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA2) (All versions), SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA2) (All versions), SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA2) (All versions). Affected devices do not conduct certain validations when interacting with them. This could allow an unauthenticated remote attacker to manipulate the devices IP address, which means the device would not be reachable. |
| General Industrial Controls Lynx+ Gateway
is missing critical authentication in the embedded web server which could allow an attacker to remotely reset the device. |
| An authenticated command injection vulnerability exists in OP5 Monitor through version 7.1.9 via the 'cmd_str' parameter in the command_test.php endpoint. A user with access to the web interface can exploit the 'Test this command' feature to execute arbitrary shell commands as the unprivileged web application user. The vulnerability resides in the configuration section of the application and requires valid login credentials with access to the command testing functionality. This issue is fixed in version 7.2.0. |
| The embedded web server on the thermostat listed version ranges contain a vulnerability that allows unauthenticated attackers, either on the local area network or from the Internet via a router with port forwarding set up, to gain direct access to the thermostat's embedded web server and reset user credentials by manipulating specific elements of the embedded web interface. |