| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| In WODESYS WD-R608U router (also known as WDR122B V2.0 and WDR28) due to lack of authentication in the configuration change module in the adm.cgi endpoint, the unauthenticated attacker can execute commands including backup creation, device restart and resetting the device to factory settings.
The vendor was notified early about this vulnerability, but didn't respond with the details of vulnerability or vulnerable version range. Only version WDR28081123OV1.01 was tested and confirmed as vulnerable, other versions were not tested and might also be vulnerable. |
| Improper handling of WiFi information by framework services can allow certain malicious applications to obtain sensitive information. |
| When using special mode to connect to enterprise wifi, certain options are not properly configured and attackers can pretend to be enterprise wifi through a carefully constructed wifi with the same name, which can lead to man-in-the-middle attacks. |
| A low privileged remote attacker may modify the docker settings setup of the device, leading to a limited DoS. |
| An issue in Plug n Play Camera com.starvedia.mCamView.zwave 5.5.1 allows a remote attacker to obtain sensitive information via the firmware update process |
| A low privileged remote attacker may modify the boot mode configuration setup of the device, leading to modification of the firmware upgrade process or a denial-of-service attack. |
| Pix-Link LV-WR21Q does not enforce any form of authentication for endpoint /goform/getHomePageInfo. Remote unauthenticated attacker is able to use this endpoint to e.g: retrieve cleartext password to the access point.
The vendor was notified early about this vulnerability, but didn't respond with the details of vulnerability or vulnerable version range. Only version V108_108 was tested and confirmed as vulnerable, other versions were not tested and might also be vulnerable. |
| CWE-306: Missing Authentication for Critical Function vulnerability exists that could
cause exposure of private data when an already generated “logcaptures” archive is accessed
directly by HTTPS. |
| A device takeover vulnerability exists in the Rockwell Automation Power Monitor 1000. This vulnerability allows configuration of a new Policyholder user without any authentication via API. Policyholder user is the most privileged user that can perform edit operations, creating admin users and performing factory reset. |
| iSeeQ Hybrid DVR WH-H4 1.03R contains an unauthenticated vulnerability in the get_jpeg script that allows unauthorized access to live video streams. Attackers can retrieve video snapshots from specific camera channels by sending requests to the /cgi-bin/get_jpeg endpoint without authentication. |
| A vulnerability allows unauthorized access to functionality inadequately constrained by ACLs. Attackers may exploit this to unauthenticated execute commands potentially leading to unauthorized data manipulation, access to privileged functions, or even the execution of arbitrary code. |
| The web application allows an unauthenticated remote attacker to learn information about existing user accounts with their corresponding role due to missing authentication for critical function. |
| Peppermint Ticket Management 0.4.6 is vulnerable to Incorrect Access Control. A regular registered user is able to elevate his privileges to admin and gain complete access to the system as the authorization mechanism is not validated on the server side and only on the client side. This can result, for example, in creating a new admin user in the system which enables persistent access for the attacker as an administrator. |
| Missing Authentication for Critical Function vulnerability in the mobile monitoring feature of Mitsubishi Electric GENESIS64 versions 10.97.2 and prior, Mitsubishi Electric ICONICS Suite versions 10.97.2 and prior, Mitsubishi Electric Hyper Historian versions 10.97.2 and prior, Mitsubishi Electric AnalytiX versions 10.97.2 and prior, Mitsubishi Electric MobileHMI versions 10.97.2 and prior, Mitsubishi Electric IoTWorX version 10.95, Mitsubishi Electric MC Works64 all versions, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions Hyper Historian versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions AnalytiX versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions MobileHMI versions 10.97.2 and prior, and Mitsubishi Electric Iconics Digital Solutions IoTWorX version 10.95 allows a remote unauthenticated attacker to bypass proper authentication and log in to the system when all of the following conditions are met: (1) Active Directory is used in the security setting (2) "Automatic log in" option is enabled in the security setting (3) The IcoAnyGlass IIS Application Pool is running under an Active Directory Domain Account. (4) The IcoAnyGlass IIS Application Pool account is included in GENESIS64, ICONCIS Suite, and MC Works64 Security and has permission to log in. |
| An unauthenticated remote attacker can get access without password protection to the affected device. This enables the unprotected read-only access to the stored measurement data. |
| Nedap Librix Ecoreader
is missing authentication for critical functions that could allow an
unauthenticated attacker to potentially execute malicious code. |
| The privileged user could log in without sufficient credentials after enabling an application protocol. This security issue has been fixed in the latest script patch latest version of of Eaton BLSS (7.3.0.SCP004). |
| Sensitive information disclosure due to missing authentication. The following products are affected: Acronis True Image (macOS) before build 41725, Acronis True Image (Windows) before build 41736, Acronis True Image OEM (macOS) before build 42571, Acronis True Image OEM (Windows) before build 42575. |
| A vulnerability classified as problematic was found in Lucky LM-520-SC, LM-520-FSC and LM-520-FSC-SAM up to 20250321. Affected by this vulnerability is an unknown functionality. The manipulation leads to missing authentication. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. |
| FLIR thermal traffic cameras contain an unauthenticated vulnerability that allows remote attackers to access live video streams without credentials. Attackers can directly retrieve video streams by accessing specific endpoints like /live.mjpeg, /snapshot.jpg, and RTSP streaming URLs without authentication. |