| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| An authenticated administrator could modify the Created By username for a user account |
| The OpenTelemetry Collector module AWS firehose receiver is for ingesting AWS Kinesis Data Firehose delivery stream messages and parsing the records received based on the configured record type. `awsfirehosereceiver` allows unauthenticated remote requests, even when configured to require a key. OpenTelemetry Collector can be configured to receive CloudWatch metrics via an AWS Firehose Stream. Firehose sets the header `X-Amz-Firehose-Access-Key` with an arbitrary configured string. The OpenTelemetry Collector awsfirehosereceiver can optionally be configured to require this key on incoming requests. However, when this is configured it **still accepts incoming requests with no key**. Only OpenTelemetry Collector users configured with the “alpha” `awsfirehosereceiver` module are affected. This module was added in version v0.49.0 of the “Contrib” distribution (or may be included in custom builds). There is a risk of unauthorized users writing metrics. Carefully crafted metrics could hide other malicious activity. There is no risk of exfiltrating data. It’s likely these endpoints will be exposed to the public internet, as Firehose does not support private HTTP endpoints. A fix was introduced in PR #34847 and released with v0.108.0. All users are advised to upgrade. There are no known workarounds for this vulnerability. |
| The MSAL library enabled acquisition of security tokens to call protected APIs. MSAL.NET applications targeting Xamarin Android and .NET Android (e.g., MAUI) using the library from versions 4.48.0 to 4.60.0 are impacted by a low severity vulnerability.
A malicious application running on a customer Android device can cause local denial of service against applications that were built using MSAL.NET for authentication on the same device (i.e., prevent the user of the legitimate application from logging in) due to incorrect activity export configuration. MSAL.NET version 4.60.1 includes the fix. As a workaround, a developer may explicitly mark the MSAL.NET activity non-exported. |
| Lack of authorisation in Deporsite by T-INNOVA. This vulnerability allows an unauthenticated attacker to change other users' profile pictures via a POST request using the parameters ‘IdPersona’ and “Foto” in ‘/ajax/TInnova_c/FotoUsuario/llamadaAjax/uploadImage’. |
| A Local Code Execution Vulnerability exists in the product and version listed above. The vulnerability is due to a default setting in Windows and allows access to the Command Prompt as a higher privileged user. |
| A vulnerability has been identified in the port ACL functionality of AOS-CX software running on the HPE Aruba Networking CX 9300 Switch Series only and affects:
- AOS-CX 10.14.xxxx : All patches
- AOS-CX 10.15.xxxx : 10.15.1000 and below
The vulnerability is specific to traffic originated by the CX 9300 switch platform and could allow an attacker to bypass ACL rules applied to routed ports on egress. As a result, port ACLs are not correctly enforced, which could lead to unauthorized traffic flow and violations of security policies. Egress VLAN ACLs and Routed VLAN ACLs are not affected by this vulnerability. |
| Step CA is an online certificate authority for secure, automated certificate management for DevOps. Prior to 0.29.0, there is an improper authorization check for SSH certificate revocation. This affects deployments configured with the SSHPOP provisioner. This vulnerability is fixed in 0.29.0. |
| An issue in Flipsnack v.18/03/2024 allows a local attacker to obtain sensitive information via the reader.gz.js file. |
| ListCheck.exe developed by Acer has a Local Privilege Escalation vulnerability. Authenticated local attackers can replace ListCheck.exe with a malicious executable of the same name, which will be executed by the system and result in privilege escalation. |
| Valtimo is a platform for Business Process Automation. In versions starting from 11.0.0.RELEASE to 11.3.3.RELEASE and 12.0.0.RELEASE to 12.12.0.RELEASE, all objects for which an object-management configuration exists can be listed, viewed, edited, created or deleted by unauthorised users. If object-urls are exposed via other channels, the contents of these objects can be viewed independent of object-management configurations. This issue has been patched in version 12.13.0.RELEASE. A workaround for this issue involves overriding the endpoint security as defined in ObjectenApiHttpSecurityConfigurer and ObjectManagementHttpSecurityConfigurer. Depending on the implementation, this could result in loss of functionality. |
| Systems running the Instaclustr
fork of Stratio's Cassandra-Lucene-Index plugin versions 4.0-rc1-1.0.0
through 4.0.16-1.0.0 and 4.1.2-1.0.0 through 4.1.8-1.0.0, installed into
Apache Cassandra version 4.x, are susceptible to a vulnerability which
when successfully exploited could allow authenticated Cassandra users to
remotely bypass RBAC and escalate their privileges. |
| When a notification relating to low battery appears for a user with whom the device has been shared, tapping the notification grants full access to the power settings of that device. |
| SAP NetWeaver allows an attacker to bypass authorization checks, enabling them to view portions of ABAP code that would normally require additional validation. Once logged into the ABAP system, the attacker can run a specific transaction that exposes sensitive system code without proper authorization. This vulnerability compromises the confidentiality. |
| A vulnerability has been identified in RUGGEDCOM RST2428P (6GK6242-6PA00) (All versions < V3.2), SCALANCE XCH328 (6GK5328-4TS01-2EC2) (All versions < V3.2), SCALANCE XCM324 (6GK5324-8TS01-2AC2) (All versions < V3.2), SCALANCE XCM328 (6GK5328-4TS01-2AC2) (All versions < V3.2), SCALANCE XCM332 (6GK5332-0GA01-2AC2) (All versions < V3.2), SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3) (All versions < V3.2), SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3) (All versions < V3.2), SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3) (All versions < V3.2), SCALANCE XRM334 (230V AC, 2x10G, 24xSFP, 8xSFP+) (6GK5334-5TS01-3AR3) (All versions < V3.2), SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3) (All versions < V3.2), SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3) (All versions < V3.2), SCALANCE XRM334 (24V DC, 2x10G, 24xSFP, 8xSFP+) (6GK5334-5TS01-2AR3) (All versions < V3.2), SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3) (All versions < V3.2), SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3) (All versions < V3.2), SCALANCE XRM334 (2x230V AC, 2x10G, 24xSFP, 8xSFP+) (6GK5334-5TS01-4AR3) (All versions < V3.2). An internal session termination functionality in the web interface of affected products contains an incorrect authorization check vulnerability. This could allow an authenticated remote attacker with "guest" role to terminate legitimate users' sessions. |
| A vulnerability has been identified in RUGGEDCOM RST2428P (6GK6242-6PA00) (All versions < V3.2), SCALANCE XCH328 (6GK5328-4TS01-2EC2) (All versions < V3.2), SCALANCE XCM324 (6GK5324-8TS01-2AC2) (All versions < V3.2), SCALANCE XCM328 (6GK5328-4TS01-2AC2) (All versions < V3.2), SCALANCE XCM332 (6GK5332-0GA01-2AC2) (All versions < V3.2), SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3) (All versions < V3.2), SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3) (All versions < V3.2), SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3) (All versions < V3.2), SCALANCE XRM334 (230V AC, 2x10G, 24xSFP, 8xSFP+) (6GK5334-5TS01-3AR3) (All versions < V3.2), SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3) (All versions < V3.2), SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3) (All versions < V3.2), SCALANCE XRM334 (24V DC, 2x10G, 24xSFP, 8xSFP+) (6GK5334-5TS01-2AR3) (All versions < V3.2), SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3) (All versions < V3.2), SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3) (All versions < V3.2), SCALANCE XRM334 (2x230V AC, 2x10G, 24xSFP, 8xSFP+) (6GK5334-5TS01-4AR3) (All versions < V3.2). The "Load Rollback" functionality in the web interface of affected products contains an incorrect authorization check vulnerability. This could allow an authenticated remote attacker with "guest" role to make the affected product roll back configuration changes made by privileged users. |
| An issue in the WaterToken smart contract (which can be run on the Ethereum blockchain) allows remote attackers to have an unspecified impact. NOTE: this is disputed by third parties because the impact is limited to function calls. |
| An issue in the PepeGxng smart contract (which can be run on the Ethereum blockchain) allows remote attackers to have an unspecified impact via the _transfer function. NOTE: this is disputed by third parties because the impact is limited to function calls. |
| The python_food ordering system V1.0 has an unauthorized vulnerability that leads to the leakage of sensitive user information. Attackers can access it through https://ip:port/api/myapp/index/user/info?id=1 And modify the ID value to obtain sensitive user information beyond authorization. |
| Incorrect Authorization vulnerability in OpenText™ Operations Bridge Manager. The vulnerability could allows privilege escalation by authenticated users.This issue affects Operations Bridge Manager: 2023.05, 23.4, 24.2, 24.4. |
| Lack of authorization of the InputManager D-Bus interface in
InputPlumber versions before v0.63.0 can lead to local Denial-of-Service,
information leak or even privilege escalation in the context of the
currently active user session. |