| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| An authenticated command injection vulnerability exists in OP5 Monitor through version 7.1.9 via the 'cmd_str' parameter in the command_test.php endpoint. A user with access to the web interface can exploit the 'Test this command' feature to execute arbitrary shell commands as the unprivileged web application user. The vulnerability resides in the configuration section of the application and requires valid login credentials with access to the command testing functionality. This issue is fixed in version 7.2.0. |
| FLIR Thermal Camera F/FC/PT/D Stream firmware version 8.0.0.64 contains an unauthenticated vulnerability that allows remote attackers to access live camera streams without credentials. Attackers can exploit the vulnerability to view unauthorized thermal camera video feeds across multiple camera series without requiring any authentication. |
| The affected products allow unauthenticated access to Open Network Video Interface Forum (ONVIF) services, which may allow an attacker unauthorized access to camera configuration information. |
| The Iskra iHUB and iHUB Lite smart metering gateway exposes its web management interface without requiring authentication, allowing unauthenticated users to access and modify critical device settings. |
| Password guessing limits could be bypassed when using LDAP authentication. |
| The Linux Kernel lockdown mode for kernel versions starting on 6.12 and above for Fedora Linux has the lockdown mode disabled without any warning. This may allow an attacker to gain access to sensitive information such kernel memory mappings, I/O ports, BPF and kprobes. Additionally unsigned modules can be loaded, leading to execution of untrusted code breaking breaking any Secure Boot protection. This vulnerability affects only Fedora Linux. |
| A vulnerability allows unauthorized access to functionality inadequately constrained by ACLs. Attackers may exploit this to unauthenticated execute commands potentially leading to unauthorized data manipulation, access to privileged functions, or even the execution of arbitrary code. |
| An unauthenticated command injection vulnerability exists in WePresent WiPG-1000 firmware versions prior to 2.2.3.0, due to improper input handling in the undocumented /cgi-bin/rdfs.cgi endpoint. The Client parameter is not sanitized before being passed to a system call, allowing an unauthenticated remote attacker to execute arbitrary commands as the web server user. |
| Improper resource management in firmware of some Solidigm DC Products may allow an attacker with local or physical access to gain un-authorized access to a locked storage device. |
| Remote Control Server, maintained by Steppschuh, 3.1.1.12 allows unauthenticated remote code execution when authentication is disabled, which is the default configuration. The server exposes a custom UDP-based control protocol that accepts remote keyboard input events without verification. An attacker on the same network can issue a sequence of keystroke commands to launch a system shell and execute arbitrary commands, resulting in full system compromise. |
| When using special mode to connect to enterprise wifi, certain options are not properly configured and attackers can pretend to be enterprise wifi through a carefully constructed wifi with the same name, which can lead to man-in-the-middle attacks. |
| WF2220 exposes endpoint /cgi-bin-igd/netcore_get.cgi that returns configuration of the device to unauthorized users. Returned configuration includes cleartext password.
The vendor was contacted early about this disclosure but did not respond in any way. |
| On Mercku M6a devices through 2.1.0, session tokens remain valid for at least months in some cases. |
| Improper authentication vulnerability in exists in multiple printers and scanners which implement Web Based Management provided by BROTHER INDUSTRIES, LTD. If this vulnerability is exploited, a network-adjacent user who can access the product may impersonate an administrative user. As for the details of affected product names, model numbers, and versions, refer to the information provided by the respective vendors listed under [References]. |
| The affected product allows unauthenticated access to Real Time Streaming Protocol (RTSP) services, which may allow an attacker unauthorized access to camera configuration information. |
| An improper exception check in Palo Alto Networks Prisma Access Browser allows a low privileged user to prevent Prisma Access Browser from applying it's Policy Rules. This enables the user to use Prisma Access Browser without any restrictions. |
| Missing Authentication for Critical Function vulnerability in the mobile monitoring feature of Mitsubishi Electric GENESIS64 versions 10.97.2 and prior, Mitsubishi Electric ICONICS Suite versions 10.97.2 and prior, Mitsubishi Electric Hyper Historian versions 10.97.2 and prior, Mitsubishi Electric AnalytiX versions 10.97.2 and prior, Mitsubishi Electric MobileHMI versions 10.97.2 and prior, Mitsubishi Electric IoTWorX version 10.95, Mitsubishi Electric MC Works64 all versions, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions Hyper Historian versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions AnalytiX versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions MobileHMI versions 10.97.2 and prior, and Mitsubishi Electric Iconics Digital Solutions IoTWorX version 10.95 allows a remote unauthenticated attacker to bypass proper authentication and log in to the system when all of the following conditions are met: (1) Active Directory is used in the security setting (2) "Automatic log in" option is enabled in the security setting (3) The IcoAnyGlass IIS Application Pool is running under an Active Directory Domain Account. (4) The IcoAnyGlass IIS Application Pool account is included in GENESIS64, ICONCIS Suite, and MC Works64 Security and has permission to log in. |
| An issue in Casa Systems NTC-221 version 2.0.99.0 and before allows a remote attacker to execute arbitrary code via a crafted payload to the /www/cgi-bin/nas.cgi component. |
| OpenID Connect Core through 1.0 errata set 2 allows audience injection in certain situations. When the private_key_jwt authentication mechanism is used, a malicious Authorization Server could trick a Client into writing attacker-controlled values into the audience, including token endpoints or issuer identifiers of other Authorization Servers. The malicious Authorization Server could then use these private key JWTs to impersonate the Client. |
| An issue was discovered in TitanHQ SpamTitan Email Security Gateway 8.00.x before 8.00.101 and 8.01.x before 8.01.14. The file quarantine.php within the SpamTitan interface allows unauthenticated users to trigger account-level actions using a crafted GET request. Notably, when a non-existent email address is provided as part of the email parameter, SpamTitan will automatically create a user record and associate quarantine settings with it - all without requiring authentication. |