| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| This vulnerability exists in Meon KYC solutions due to missing restrictions on the number of incorrect One-Time Password (OTP) attempts through certain API endpoints of login process. A remote attacker could exploit this vulnerability by performing a brute force attack on OTP, which could lead to gain unauthorized access to other user accounts. |
| Unexpected authentication form rendering in HTML Form Adapter using only non-default redirectless mode in PingFederate allows authentication attempts which may enable brute force login attacks. |
| EasyFlow .NET and EasyFlow AiNet, developed by Digiwin, has a Missing Authentication vulnerability, allowing unauthenticated remote attackers to obtain database administrator credentials via a specific functionality. |
| A local privilege escalation vulnerability exists in lastore-daemon, the system package manager daemon used in Deepin Linux (developed by Wuhan Deepin Technology Co., Ltd.). In versions 0.9.53-1 (Deepin 15.5) and 0.9.66-1 (Deepin 15.7), the D-Bus configuration permits any user in the sudo group to invoke the InstallPackage method without password authentication. By default, the first user created on Deepin is in the sudo group. An attacker with shell access can craft a .deb package containing a malicious post-install script and use dbus-send to install it via lastore-daemon, resulting in arbitrary code execution as root. |
| ZF Roll Stability Support Plus (RSSPlus)
is vulnerable to an authentication bypass vulnerability targeting
deterministic RSSPlus SecurityAccess service seeds, which may allow an
attacker to remotely (proximal/adjacent with RF equipment or via pivot
from J2497 telematics devices) call diagnostic functions intended for
workshop or repair scenarios. This can impact system availability,
potentially degrading performance or erasing software, however the
vehicle remains in a safe vehicle state. |
| Anheng Mingyu Operation and Maintenance Audit and Risk Control System up to 2023-08-10 contains a server-side request forgery (SSRF) vulnerability in the xmlrpc.sock handler. The product accepts specially crafted XML-RPC requests that can be used to instruct the server to connect to internal unix socket RPC endpoints and perform privileged XML-RPC methods. An attacker able to send such requests can invoke administrative RPC methods via the unix socket interface to create arbitrary user accounts on the system, resulting in account creation and potential takeover of the bastion host. VulnCheck has observed this vulnerability being exploited in the wild as of 2025-10-30 at 00:30:17.837319 UTC. |
| A vulnerability was found in eGauge EG3000 Energy Monitor 3.6.3. It has been classified as problematic. This affects an unknown part of the component Setting Handler. The manipulation leads to missing authentication. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. |
| The OTP Integration Kit for PingFederate fails to enforce HTTP method validation and state validation properly. The server advances the authentication state without verifying the OTP, thereby bypassing multi-factor authentication. |
| On the exos 9300 server, a SOAP API is reachable on port 8002. This API does not require any authentication prior to sending requests. Therefore, network access to the exos server allows e.g. the creation of arbitrary access log events as well as querying the 2FA PINs associated with the enrolled chip cards. |
| The exos 9300 application can be used to configure Access Managers (e.g. 92xx, 9230 and 9290). The configuration is done in a graphical user interface on the dormakaba exos server. As soon as the save button is clicked in exos 9300, the whole configuration is sent to the selected Access Manager via SOAP. The SOAP request is sent without any prior authentication or authorization by default. Though authentication and authorization can be configured using IPsec for 92xx-K5 devices and mTLS for 92xx-K7 devices, it is not enabled by default and must therefore be activated with additional steps.
This insecure default allows an attacker with network level access to completely control the whole environment. An attacker is for example easily able to conduct the following tasks without prior authentication:
- Re-configure Access Managers (e.g. remove alarming system requirements)
- Freely re-configure the inputs and outputs
- Open all connected doors permanently
- Open all doors for a defined time interval
- Change the admin password
- and many more
Network level access can be gained due to an insufficient network segmentation as well as missing LAN firewalls. Devices with an insecure configuration have been identified to be directly exposed to the internet. |
| WHILL Model C2 Electric Wheelchairs and Model F Power Chairs do not enforce authentication for Bluetooth connections. An attacker within range can pair with the device and issue movement commands, override speed restrictions, and manipulate configuration profiles without any credentials or user interaction. |
| A Missing Authentication for Critical Function vulnerability in the UniFi Connect EV Station Pro may allow a malicious actor with physical or adjacent access to perform an unauthorized factory reset.
Affected Products:
UniFi Connect EV Station Pro (Version 1.5.18 and earlier)
Mitigation:
Update UniFi Connect EV Station Pro to Version 1.5.27 or later |
| Nautobot Single Source of Truth (SSoT) is an app for Nautobot. Prior to version 3.10.0, an unauthenticated attacker could access this page to view the Service Now public instance name e.g. companyname.service-now.com. This is considered low-value information. This does not expose the Secret, the Secret Name, or the Secret Value for the Username/Password for Service-Now.com. An unauthenticated member would not be able to change the instance name, nor set a Secret. There is not a way to gain access to other pages Nautobot through the unauthenticated Configuration page. This issue has been patched in version 3.10.0. |
| In the Airoha Bluetooth audio SDK, there is a possible permission bypass that allows access critical data of RACE protocol through Bluetooth LE GATT service. This could lead to remote escalation of privilege with no additional execution privileges needed. User interaction is not needed for exploitation. |
| The ASPECT system allows users to bypass authentication.
This issue affects all versions of ASPECT |
| The devices allow access to an unprotected endpoint that allows MPFS
file system binary image upload without authentication. The MPFS2 file
system module provides a light-weight read-only file system that can be
stored in external EEPROM, external serial flash, or internal flash
program memory. This file system serves as the basis for the HTTP2 web
server module, but is also used by the SNMP module and is available to
other applications that require basic read-only storage capabilities.
This can be exploited to overwrite the flash program memory that holds
the web server's main interfaces and execute arbitrary code. |
| A vulnerability was found in rowboatlabs rowboat up to 8096eaf63b5a0732edd8f812bee05b78e214ee97. It has been rated as critical. Affected by this issue is the function PUT of the file apps/rowboat/app/api/uploads/[fileId]/route.ts of the component Session Handler. The manipulation of the argument params leads to missing authentication. The attack may be launched remotely. Continious delivery with rolling releases is used by this product. Therefore, no version details of affected nor updated releases are available. It is expected that this issue will be fixed in the near future. |
| The Brightpick Internal Logic Control web interface is accessible
without requiring user authentication. An unauthorized user could
exploit this interface to manipulate robot control functions, including
initiating or halting runners, assigning jobs, clearing stations, and
deploying storage totes. |
| A potential security vulnerability has been identified in HP Sure Start’s protection of the Intel Flash Descriptor in certain HP PC products, which might allow security bypass, arbitrary code execution, loss of integrity or confidentiality, or denial of service. HP is releasing BIOS updates to mitigate the potential vulnerability. |
| EPSON WebConfig and Epson Web Control for SEIKO EPSON Projector Products do not restrict excessive authentication attempts. An administrative user's password may be identified through a brute force attack. |