Search Results (366 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2026-25499 1 Bpg 2 Terraform-provider-proxmox, Terraform Provider 2026-04-17 7.5 High
Terraform / OpenTofu Provider adds support for Proxmox Virtual Environment. Prior to version 0.93.1, in the SSH configuration documentation, the sudoer line suggested is insecure and can result in escaping the folder using ../, allowing any files on the system to be edited. This issue has been patched in version 0.93.1.
CVE-2026-25894 1 Frangoteam 1 Fuxa 2026-04-17 9.8 Critical
FUXA is a web-based Process Visualization (SCADA/HMI/Dashboard) software. An insecure default configuration in FUXA allows an unauthenticated, remote attacker to gain administrative access and execute arbitrary code on the server. This affects FUXA through version 1.2.9 when authentication is enabled, but the administrator JWT secret is not configured. This issue has been patched in FUXA version 1.2.10.
CVE-2026-23116 1 Linux 1 Linux Kernel 2026-04-17 5.5 Medium
In the Linux kernel, the following vulnerability has been resolved: pmdomain: imx8m-blk-ctrl: Remove separate rst and clk mask for 8mq vpu For i.MX8MQ platform, the ADB in the VPUMIX domain has no separate reset and clock enable bits, but is ungated and reset together with the VPUs. So we can't reset G1 or G2 separately, it may led to the system hang. Remove rst_mask and clk_mask of imx8mq_vpu_blk_ctl_domain_data. Let imx8mq_vpu_power_notifier() do really vpu reset.
CVE-2026-28775 2 Datacast, International Datacasting Corporation (idc) 3 Sfx2100, Sfx2100 Firmware, Sfx2100 Series Superflex Satellitereceiver 2026-04-17 9.8 Critical
An unauthenticated Remote Code Execution (RCE) vulnerability exists in the SNMP service of International Datacasting Corporation (IDC) SFX Series SuperFlex SatelliteReceiver. The deployment insecurely provisions the `private` SNMP community string with read/write access by default. Because the SNMP agent runs as root, an unauthenticated remote attacker can utilize `NET-SNMP-EXTEND-MIB` directives, abusing the fact that the system runs a vulnerable version of net-snmp pre 5.8, to execute arbitrary operating system commands with root privileges.
CVE-2026-1675 1 Wordpress 1 Wordpress 2026-04-15 5.3 Medium
The Advanced Country Blocker plugin for WordPress is vulnerable to Authorization Bypass in all versions up to, and including, 2.3.1 due to the use of a predictable default value for the secret bypass key created during installation without requiring users to change it. This makes it possible for unauthenticated attackers to bypass the geolocation blocking mechanism by appending the key to any URL on sites where the administrator has not changed the default value.
CVE-2026-26122 1 Microsoft 2 Aci Confidential Containers, Microsoft Aci Confidential Containers 2026-04-15 6.5 Medium
Initialization of a resource with an insecure default in Azure Compute Gallery allows an authorized attacker to disclose information over a network.
CVE-2026-34780 2 Electron, Electronjs 2 Electron, Electron 2026-04-15 8.4 High
Electron is a framework for writing cross-platform desktop applications using JavaScript, HTML and CSS. From versions 39.0.0-alpha.1 to before 39.8.0, 40.0.0-alpha.1 to before 40.7.0, and 41.0.0-alpha.1 to before 41.0.0-beta.8, apps that pass VideoFrame objects (from the WebCodecs API) across the contextBridge are vulnerable to a context isolation bypass. An attacker who can execute JavaScript in the main world (for example, via XSS) can use a bridged VideoFrame to gain access to the isolated world, including any Node.js APIs exposed to the preload script. Apps are only affected if a preload script returns, resolves, or passes a VideoFrame object to the main world via contextBridge.exposeInMainWorld(). Apps that do not bridge VideoFrame objects are not affected. This issue has been patched in versions 39.8.0, 40.7.0, and 41.0.0-beta.8.
CVE-2018-25169 2 Ampps, Softaculous 2 Ampps, Ampps 2026-04-15 7.5 High
AMPPS 2.7 contains a denial of service vulnerability that allows remote attackers to crash the service by sending malformed data to the default HTTP port. Attackers can establish multiple socket connections and transmit invalid payloads to exhaust server resources and cause service unavailability.
CVE-2024-41975 2026-04-15 5.3 Medium
An unauthenticated remote attacker can gain limited information of the PLC network but the user management of the PLCs prevents the actual access to the PLCs.
CVE-2025-46599 1 K3s 1 K3s 2026-04-15 6.8 Medium
CNCF K3s 1.32 before 1.32.4-rc1+k3s1 has a Kubernetes kubelet configuration change with the unintended consequence that, in some situations, ReadOnlyPort is set to 10255. For example, the default behavior of a K3s online installation might allow unauthenticated access to this port, exposing credentials.
CVE-2025-31930 2026-04-15 8.8 High
A vulnerability has been identified in IEC 1Ph 7.4kW Child socket (8EM1310-2EH04-0GA0) (All versions < V2.135), IEC 1Ph 7.4kW Child socket/ shutter (8EM1310-2EN04-0GA0) (All versions < V2.135), IEC 1Ph 7.4kW Parent cable 7m (8EM1310-2EJ04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent cable 7m incl. SIM (8EM1310-2EJ04-3GA2) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket (8EM1310-2EH04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket incl. SIM (8EM1310-2EH04-3GA2) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket/ shutter (8EM1310-2EN04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket/ shutter SIM (8EM1310-2EN04-3GA2) (All versions < V2.135), IEC 3Ph 22kW Child cable 7m (8EM1310-3EJ04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Child socket (8EM1310-3EH04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Child socket/ shutter (8EM1310-3EN04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Parent cable 7m (8EM1310-3EJ04-3GA1) (All versions < V2.135), IEC 3Ph 22kW Parent cable 7m incl. SIM (8EM1310-3EJ04-3GA2) (All versions < V2.135), IEC 3Ph 22kW Parent socket (8EM1310-3EH04-3GA1) (All versions < V2.135), IEC 3Ph 22kW Parent socket incl. SIM (8EM1310-3EH04-3GA2) (All versions < V2.135), IEC 3Ph 22kW Parent socket/ shutter (8EM1310-3EN04-3GA1) (All versions < V2.135), IEC 3Ph 22kW Parent socket/ shutter SIM (8EM1310-3EN04-3GA2) (All versions < V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA0) (All versions < V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA1) (All versions < V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA2) (All versions < V2.135), IEC ERK 3Ph 22 kW Child socket (8EM1310-3FH04-0GA0) (All versions < V2.135), IEC ERK 3Ph 22 kW Parent socket (8EM1310-3FH04-3GA1) (All versions < V2.135), IEC ERK 3Ph 22 kW Parent socket incl. SI (8EM1310-3FH04-3GA2) (All versions < V2.135), UL Commercial Cellular 48A NTEP (8EM1310-5HF14-1GA2) (All versions < V2.135), UL Commercial Child 40A w/ 15118 HW (8EM1310-4CF14-0GA0) (All versions < V2.135), UL Commercial Child 48A BA Compliant (8EM1315-5CG14-0GA0) (All versions < V2.135), UL Commercial Child 48A w/ 15118 HW (8EM1310-5CF14-0GA0) (All versions < V2.135), UL Commercial Parent 40A with Simcard (8EM1310-4CF14-1GA2) (All versions < V2.135), UL Commercial Parent 48A (USPS) (8EM1317-5CG14-1GA2) (All versions < V2.135), UL Commercial Parent 48A BA Compliant (8EM1315-5CG14-1GA2) (All versions < V2.135), UL Commercial Parent 48A with Simcard BA (8EM1310-5CF14-1GA2) (All versions < V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1310-5CG14-1GA1) (All versions < V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1314-5CG14-2FA2) (All versions < V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1315-5HG14-1GA2) (All versions < V2.135), UL Commercial Parent 48A,15118 25ft Sim (8EM1310-5CG14-1GA2) (All versions < V2.135), VersiCharge Blue™ 80A AC Cellular (8EM1315-7BG16-1FH2) (All versions < V2.135). Affected devices contain Modbus service enabled by default. This could allow an attacker connected to the same network to remotely control the EV charger.
CVE-2024-48122 2026-04-15 6.7 Medium
Insecure default configurations in HI-SCAN 6040i Hitrax HX-03-19-I allow authenticated attackers with low-level privileges to escalate to root-level privileges.
CVE-2024-28815 1 Mitel 2 Cmg Suite, Inattend 2026-04-15 9.8 Critical
A vulnerability in the BluStar component of Mitel InAttend 2.6 SP4 through 2.7 and CMG 8.5 SP4 through 8.6 could allow access to sensitive information, changes to the system configuration, or execution of arbitrary commands within the context of the system.
CVE-2025-53602 2026-04-15 5.3 Medium
Zipkin through 3.5.1 has a /heapdump endpoint (associated with the use of Spring Boot Actuator), a similar issue to CVE-2025-48927.
CVE-2025-59044 1 Himmelblau-idm 1 Himmelblau 2026-04-15 4.4 Medium
Himmelblau is an interoperability suite for Microsoft Azure Entra ID and Intune. Himmelblau 0.9.x derives numeric GIDs for Entra ID groups from the group display name when himmelblau.conf `id_attr_map = name` (the default configuration). Because Microsoft Entra ID allows multiple groups with the same `displayName` (including end-user–created personal/O365 groups, depending on tenant policy), distinct directory groups can collapse to the same numeric GID on Linux. This issue only applies to Himmelblau versions 0.9.0 through 0.9.22. Any resource or service on a Himmelblau-joined host that enforces authorization by numeric GID (files/dirs, etc.) can be unintentionally accessible to a user who creates or joins a different Entra/O365 group that happens to share the same `displayName` as a privileged security group. Users should upgrade to 0.9.23, or 1.0.0 or later, to receive a patch. Group to GID mapping now uses Entra ID object IDs (GUIDs) and does not collide on same-name groups. As a workaround, use tenant policy hardening to restrict arbitrary group creation until all hosts are patched.
CVE-2025-1960 2026-04-15 9.8 Critical
CWE-1188: Initialization of a Resource with an Insecure Default vulnerability exists that could cause an attacker to execute unauthorized commands when a system’s default password credentials have not been changed on first use. The default username is not displayed correctly in the WebHMI interface.
CVE-2024-56433 1 Shadow-maint 1 Shadow-utils 2026-04-15 3.6 Low
shadow-utils (aka shadow) 4.4 through 4.17.0 establishes a default /etc/subuid behavior (e.g., uid 100000 through 165535 for the first user account) that can realistically conflict with the uids of users defined on locally administered networks, potentially leading to account takeover, e.g., by leveraging newuidmap for access to an NFS home directory (or same-host resources in the case of remote logins by these local network users). NOTE: it may also be argued that system administrators should not have assigned uids, within local networks, that are within the range that can occur in /etc/subuid.
CVE-2025-24288 1 Versa 1 Director 2026-04-15 9.8 Critical
The Versa Director software exposes a number of services by default and allow attackers an easy foothold due to default credentials and multiple accounts (most with sudo access) that utilize the same default credentials. By default, Versa director exposes ssh and postgres to the internet, alongside a host of other services. Versa Networks is not aware of any reported instance where this vulnerability was exploited. Proof of concept for this vulnerability has been disclosed by third party security researchers. Workarounds or Mitigation: Versa recommends the following security controls: 1) Change default passwords to complex passwords 2) Passwords must be complex with at least 8 characters that comprise of upper case, and lower case alphabets, as well as at at least one digit, and one special character 3) Passwords must be changed at least every 90 days 4) Password change history is checked to ensure that the at least the last 5 passwords must be used when changing password. 5) Review and audit logs for all authentication attempts to check for unauthorized/suspicious login attempts and enforce remediation steps.
CVE-2025-41438 2026-04-15 9.8 Critical
The CS5000 Fire Panel is vulnerable due to a default account that exists on the panel. Even though it is possible to change this by SSHing into the device, it has remained unchanged on every installed system observed. This account is not root but holds high-level permissions that could severely impact the device's operation if exploited.
CVE-2024-41995 1 Ricoh Company Ltd 1 Javatm Platform 2026-04-15 7.5 High
Initialization of a resource with an insecure default vulnerability exists in JavaTM Platform Ver.12.89 and earlier. If this vulnerability is exploited, the product may be affected by some known TLS1.0 and TLS1.1 vulnerabilities. As for the specific products/models/versions of MFPs and printers that contain JavaTM Platform, see the information provided by the vendor.