| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Improper Access Control issue in the Workflow component of Fortra's FileCatalyst allows unauthenticated users to upload arbitrary files via the order forms page. |
| NUP Portal developed by NewType Infortech has a Missing Authentication vulnerability, allowing unauthenticated remote attackers to directly upload files. If the attacker manages to bypass the file extension restrictions, they could upload a webshell and execute it on the server side. |
| This vulnerability exists in Meon KYC solutions due to missing restrictions on the number of incorrect One-Time Password (OTP) attempts through certain API endpoints of login process. A remote attacker could exploit this vulnerability by performing a brute force attack on OTP, which could lead to gain unauthorized access to other user accounts. |
| General Industrial Controls Lynx+ Gateway
is missing critical authentication in the embedded web server which could allow an attacker to remotely reset the device. |
| ZF Roll Stability Support Plus (RSSPlus)
is vulnerable to an authentication bypass vulnerability targeting
deterministic RSSPlus SecurityAccess service seeds, which may allow an
attacker to remotely (proximal/adjacent with RF equipment or via pivot
from J2497 telematics devices) call diagnostic functions intended for
workshop or repair scenarios. This can impact system availability,
potentially degrading performance or erasing software, however the
vehicle remains in a safe vehicle state. |
| The vulnerability allows attackers access to the root account without having to authenticate. Specifically, if the device is configured with the IP address of 10.10.10.10, the root user is automatically logged in. |
| A vulnerability was found in eGauge EG3000 Energy Monitor 3.6.3. It has been classified as problematic. This affects an unknown part of the component Setting Handler. The manipulation leads to missing authentication. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. |
| A vulnerability has been identified in CPCI85 Central Processing/Communication (All versions < V5.40), SICORE Base system (All versions < V1.4.0). Affected devices allow a remote authenticated user or an unauthenticated user with physical access to downgrade the firmware of the device. This could allow an attacker to downgrade the device to older versions with known vulnerabilities. |
| In certain IETF OAuth 2.0-related specifications, when the JSON Web Token Profile for OAuth 2.0 Client Authentication mechanism is used, there are ambiguities in the audience values of JWTs sent to authorization servers. The affected RFCs may include RFC 7523, and also RFC 7521, RFC 7522, RFC 9101 (JAR), and RFC 9126 (PAR). |
| A problem with missing authorization on SolaX Cloud platform allows taking over any SolaX solarpanel inverter of which the serial number is known. |
| The MinigameCenter module has insufficient restrictions on loading URLs, which may lead to some information leakage. |
| SpaceX Starlink Dish devices with firmware 2024.12.04.mr46620 (e.g., on Mini1_prod2) allow administrative actions via unauthenticated LAN gRPC requests, aka MARMALADE 2. The cross-origin policy can be bypassed by omitting a Referer header. In some cases, an attacker's ability to read tilt, rotation, and elevation data via gRPC can make it easier to infer the geographical location of the dish. |
| The paths "/cgi-bin/CliniNET.prd/utils/userlogstat.pl", "/cgi-bin/CliniNET.prd/utils/usrlogstat.pl", and "/cgi-bin/CliniNET.prd/utils/dblogstat.pl" expose data containing session IDs. |
| The vulnerability allows unauthenticated users to download a file containing session ID data by directly accessing the "/cgi-bin/CliniNET.prd/utils/userlogxls.pl" endpoint. |
| General Industrial Controls Lynx+ Gateway is missing critical authentication in the embedded web server which
could allow an attacker to send GET requests to obtain sensitive device
information. |
| Missing authentication for critical function vulnerability exists in AssetView and AssetView CLOUD. If exploited, the files on the server where the product is running may be obtained and/or deleted by a remote unauthenticated attacker. |
| Insufficient authentication in user account management in Yugabyte Platform allows local network attackers with a compromised user session to change critical security information without re-authentication. An attacker with user session and access to application can modify settings such as password and email without being prompted for the current password, enabling account takeover. |
| CWE-307: Improper Restriction of Excessive Authentication Attempts vulnerability exists that would allow an attacker on the local network to gain access to the user account by performing an arbitrary number of authentication attempts with different credentials on the /REST/shutdownnow endpoint. |
| Use of fixed learning codes, one code to lock the car and the other code to unlock it, in the Key Fob Transmitter in Cyclone Matrix TRF Smart Keyless Entry System, which allows a replay attack.
Research was completed on the 2024 KIA Soluto. Attack confirmed on other KIA Models in Ecuador. |
|
An authentication bypass vulnerability was identified in SMM/SMM2 and FPC that could allow an authenticated user to execute certain IPMI calls that could lead to exposure of limited system information.
|