| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Use of Hard-coded Cryptographic Key vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A and later allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthenticated attackers may view programs and project file or execute programs illegally. |
| Use of Hard-coded Password vulnerability in Mitsubishi Electric Corporation GX Works3 versions from 1.015R to 1.095Z allows a remote unauthenticated attacker to obtain information about the project file for MELSEC safety CPU modules. |
| Sanitization Management System v1.0 was discovered to contain hardcoded credentials which allows attackers to escalate privileges and access the admin panel. |
| Book Store Management System v1.0 was discovered to contain hardcoded credentials which allows attackers to escalate privileges and access the admin panel. |
| A specific file on the sERP server if Kyungrinara(ERP solution) has a fixed password with the SYSTEM authority. This vulnerability could allow attackers to leak or steal sensitive information or execute malicious commands. |
| When aborting a SFTP connection, MobaXterm before v22.1 sends a hardcoded password to the server. The server treats this as an invalid login attempt which can result in a Denial of Service (DoS) for the user if services like fail2ban are used. |
| PuddingBot is a group management bot. In version 0.0.6-b933652 and prior, the bot token is publicly exposed in main.py, making it accessible to malicious actors. The bot token has been revoked and new version is already running on the server. As of time of publication, the maintainers are planning to update code to reflect this change at a later date. |
| Rundeck is an open source automation service with a web console, command line tools and a WebAPI. Rundeck community and rundeck-enterprise docker images contained a pre-generated SSH keypair. If the id_rsa.pub public key of the keypair was copied to authorized_keys files on remote host, those hosts would allow access to anyone with the exposed private credentials. This misconfiguration only impacts Rundeck Docker instances of PagerDuty® Process Automation On Prem (formerly Rundeck) version 4.0 and earlier, not Debian, RPM or .WAR. Additionally, the id_rsa.pub file would have to be copied from the Docker image filesystem contents without overwriting it and used to configure SSH access on a host. A patch on Rundeck's `main` branch has removed the pre-generated SSH key pair, but it does not remove exposed keys that have been configured. To patch, users must run a script on hosts in their environment to search for exposed keys and rotate them. Two workarounds are available: Do not use any pre-existing public key file from the rundeck docker images to allow SSH access by adding it to authorized_keys files and, if you have copied the public key file included in the docker image, remove it from any authorized_keys files. |
| In Pexip VMR self-service portal before 3, the same SSH host key is used across different customers' installations, which allows authentication bypass. |
| Use of hard-coded credentials vulnerability in multiple Buffalo network devices allows a network-adjacent attacker to alter?configuration settings of the device. The affected products/versions are as follows: WZR-300HP firmware Ver. 2.00 and earlier, WZR-450HP firmware Ver. 2.00 and earlier, WZR-600DHP firmware Ver. 2.00 and earlier, WZR-900DHP firmware Ver. 1.15 and earlier, HW-450HP-ZWE firmware Ver. 2.00 and earlier, WZR-450HP-CWT firmware Ver. 2.00 and earlier, WZR-450HP-UB firmware Ver. 2.00 and earlier, WZR-600DHP2 firmware Ver. 1.15 and earlier, and WZR-D1100H firmware Ver. 2.00 and earlier. |
| Adobe ColdFusion versions Update 14 (and earlier) and Update 4 (and earlier) are affected by a Use of Hard-coded Credentials vulnerability that could result in application denial-of-service by gaining access to start/stop arbitrary services. Exploitation of this issue does not require user interaction. |
| MegaRAC Default Credentials Vulnerability |
| RTL8111EP-CG/RTL8111FP-CG DASH function has hard-coded password. An unauthenticated physical attacker can use the hard-coded default password during system reboot triggered by other user, to acquire partial system information such as serial number and server information. |
| MegaRAC Default Credentials Vulnerability |
| Databasir is a team-oriented relational database model document management platform. Databasir 1.01 has Use of Hard-coded Cryptographic Key vulnerability. An attacker can use hard coding to generate login credentials of any user and log in to the service background located at different IP addresses. |
| Toshiba Home gateway HEM-GW16A firmware HEM-GW16A-FW-V1.2.0 and earlier, Toshiba Home gateway HEM-GW26A firmware HEM-GW26A-FW-V1.2.0 and earlier uses hard-coded credentials, which may allow attackers to perform operations on device with administrative privileges. |
| The Comcast firmware on Cisco DPC3939 (firmware version dpc3939-P20-18-v303r20421746-170221a-CMCST) and DPC3941T (firmware version DPC3941_2.5s3_PROD_sey) devices allows remote attackers to access the web UI by establishing a session to the wan0 WAN IPv6 address and then entering unspecified hardcoded credentials. This wan0 interface cannot be accessed from the public Internet. |
| The WePresent WiPG-1500 device with firmware 1.0.3.7 has a manufacturer account that has a hardcoded username / password. Once the device is set to DEBUG mode, an attacker can connect to the device using the telnet protocol and log into the device with the 'abarco' hardcoded manufacturer account. This account is not documented, nor is the DEBUG feature or the use of telnetd on port tcp/5885. |
| An authentication bypass vulnerability exists in Schneider Electric's U.motion Builder software versions 1.2.1 and prior in which the system contains a hard-coded valid session. An attacker can use that session ID as part of the HTTP cookie of a web request, resulting in authentication bypass |
| An issue was discovered in BINOM3 Universal Multifunctional Electric Power Quality Meter. Users do not have any option to change their own passwords. |