Search

Search Results (327109 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2025-20760 1 Mediatek 51 Mt2735, Mt2737, Mt6833 and 48 more 2026-01-08 7.5 High
In Modem, there is a possible read of uninitialized heap data due to an uncaught exception. This could lead to remote denial of service, if a UE has connected to a rogue base station controlled by the attacker, with no additional execution privileges needed. User interaction is not needed for exploitation. Patch ID: MOLY01676750; Issue ID: MSV-4653.
CVE-2025-20761 2 Mediatek, Mediatk 102 Mt2735, Mt2737, Mt6833 and 99 more 2026-01-08 7.5 High
In Modem, there is a possible system crash due to incorrect error handling. This could lead to remote denial of service, if a UE has connected to a rogue base station controlled by the attacker, with no additional execution privileges needed. User interaction is not needed for exploitation. Patch ID: MOLY01311265; Issue ID: MSV-4655.
CVE-2019-25278 1 Iwt 1 Facesentry Access Control System 2026-01-08 7.5 High
FaceSentry Access Control System 6.4.8 contains a cleartext transmission vulnerability that allows remote attackers to intercept authentication credentials. Attackers can perform man-in-the-middle attacks to capture HTTP cookie authentication information during network communication.
CVE-2025-20762 1 Mediatek 16 Mt6835, Mt6835t, Mt6878 and 13 more 2026-01-08 7.5 High
In Modem, there is a possible system crash due to incorrect error handling. This could lead to remote denial of service, if a UE has connected to a rogue base station controlled by the attacker, with no additional execution privileges needed. User interaction is not needed for exploitation. Patch ID: MOLY01685181; Issue ID: MSV-4760.
CVE-2025-20778 2 Google, Mediatek 46 Android, Mt6739, Mt6761 and 43 more 2026-01-08 7.8 High
In display, there is a possible out of bounds write due to a missing bounds check. This could lead to local escalation of privilege if a malicious actor has already obtained the System privilege. User interaction is not needed for exploitation. Patch ID: ALPS10184870; Issue ID: MSV-4729.
CVE-2019-25279 1 Iwt 1 Facesentry Access Control System 2026-01-08 8.2 High
FaceSentry Access Control System 6.4.8 contains a cleartext password storage vulnerability that allows attackers to access unencrypted credentials in the device's SQLite database. Attackers can directly read sensitive login information stored in /faceGuard/database/FaceSentryWeb.sqlite without additional authentication.
CVE-2025-20779 2 Google, Mediatek 46 Android, Mt6739, Mt6761 and 43 more 2026-01-08 7 High
In display, there is a possible use after free due to a race condition. This could lead to local escalation of privilege if a malicious actor has already obtained the System privilege. User interaction is not needed for exploitation. Patch ID: ALPS10184084; Issue ID: MSV-4720.
CVE-2025-20780 2 Google, Mediatek 46 Android, Mt6739, Mt6761 and 43 more 2026-01-08 7.8 High
In display, there is a possible memory corruption due to use after free. This could lead to local escalation of privilege if a malicious actor has already obtained the System privilege. User interaction is not needed for exploitation. Patch ID: ALPS10184061; Issue ID: MSV-4712.
CVE-2025-20781 2 Google, Mediatek 46 Android, Mt6739, Mt6761 and 43 more 2026-01-08 7.8 High
In display, there is a possible memory corruption due to use after free. This could lead to local escalation of privilege if a malicious actor has already obtained the System privilege. User interaction is not needed for exploitation. Patch ID: ALPS10182914; Issue ID: MSV-4699.
CVE-2019-25282 2026-01-08 9.8 Critical
V-SOL GPON/EPON OLT Platform v2.03 contains an open redirect vulnerability in the script that allows attackers to manipulate the 'parent' GET parameter. Attackers can craft malicious links that redirect logged-in users to arbitrary websites by exploiting improper input validation in the redirect mechanism.
CVE-2025-20782 2 Google, Mediatek 46 Android, Mt6739, Mt6761 and 43 more 2026-01-08 6.7 Medium
In display, there is a possible out of bounds write due to a missing bounds check. This could lead to local escalation of privilege if a malicious actor has already obtained the System privilege. User interaction is not needed for exploitation. Patch ID: ALPS10182882; Issue ID: MSV-4685.
CVE-2025-20783 2 Google, Mediatek 46 Android, Mt6739, Mt6761 and 43 more 2026-01-08 6.7 Medium
In display, there is a possible out of bounds write due to a missing bounds check. This could lead to local escalation of privilege if a malicious actor has already obtained the System privilege. User interaction is not needed for exploitation. Patch ID: ALPS10182882; Issue ID: MSV-4684.
CVE-2025-20784 3 Google, Mediatek, Mediatk 73 Android, Mt6739, Mt6761 and 70 more 2026-01-08 6.7 Medium
In display, there is a possible memory corruption due to uninitialized data. This could lead to local escalation of privilege if a malicious actor has already obtained the System privilege. User interaction is not needed for exploitation. Patch ID: ALPS10182882; Issue ID: MSV-4683.
CVE-2025-20785 2 Google, Mediatek 46 Android, Mt6739, Mt6761 and 43 more 2026-01-08 6.7 Medium
In display, there is a possible memory corruption due to use after free. This could lead to local escalation of privilege if a malicious actor has already obtained the System privilege. User interaction is not needed for exploitation. Patch ID: ALPS10149882; Issue ID: MSV-4677.
CVE-2019-25289 1 Inim 1 Smartliving Smartlan 2026-01-08 8.8 High
SmartLiving SmartLAN <=6.x contains an authenticated remote command injection vulnerability in the web.cgi binary through the 'par' POST parameter with the 'testemail' module. Attackers can exploit the unsanitized parameter and system() function call to execute arbitrary system commands with root privileges using default credentials.
CVE-2025-20786 2 Google, Mediatek 46 Android, Mt6739, Mt6761 and 43 more 2026-01-08 6.7 Medium
In display, there is a possible memory corruption due to use after free. This could lead to local escalation of privilege if a malicious actor has already obtained the System privilege. User interaction is not needed for exploitation. Patch ID: ALPS10149882; Issue ID: MSV-4673.
CVE-2025-20787 2 Google, Mediatek 31 Android, Mt2718, Mt6739 and 28 more 2026-01-08 6.7 Medium
In display, there is a possible memory corruption due to use after free. This could lead to local escalation of privilege if a malicious actor has already obtained the System privilege. User interaction is not needed for exploitation. Patch ID: ALPS10149879; Issue ID: MSV-4658.
CVE-2025-20793 1 Mediatek 53 Mt2735, Mt2737, Mt6813 and 50 more 2026-01-08 7.5 High
In Modem, there is a possible system crash due to incorrect error handling. This could lead to remote denial of service, if a UE has connected to a rogue base station controlled by the attacker, with no additional execution privileges needed. User interaction is not needed for exploitation. Patch ID: MOLY01430930; Issue ID: MSV-4836.
CVE-2019-25290 1 Inim 1 Smartliving Smartlan 2026-01-08 5.3 Medium
Smartliving SmartLAN/G/SI <=6.x contains an unauthenticated server-side request forgery vulnerability in the GetImage functionality through the 'host' parameter. Attackers can exploit the onvif.cgi endpoint by specifying external domains to bypass firewalls and perform network enumeration through arbitrary HTTP requests.
CVE-2025-20794 2 Mediatek, Mediatk 87 Mt2735, Mt2737, Mt6813 and 84 more 2026-01-08 7.5 High
In Modem, there is a possible system crash due to improper input validation. This could lead to remote denial of service, if a UE has connected to a rogue base station controlled by the attacker, with no additional execution privileges needed. User interaction is not needed for exploitation. Patch ID: MOLY01689259 / MOLY01586470; Issue ID: MSV-4847.