| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Systech Corporation NDS-5000 Terminal Server, NDS/5008 (8 Port, RJ45), firmware Version 02D.30. Successful exploitation of this vulnerability could allow information disclosure, limit system availability, and may allow remote code execution. |
| In Honeywell WIN-PAK 4.7.2, Web and prior versions, the affected product is vulnerable to a cross-site request forgery, which may allow an attacker to remotely execute arbitrary code. |
| VISAM VBASE Editor version 11.5.0.2 and VBASE Web-Remote Module may allow weak or insecure permissions on the VBASE directory resulting in elevation of privileges or malicious effects on the system the next time a privileged user runs the application. |
| In Moxa ioLogik 2500 series firmware, Version 3.0 or lower, and IOxpress configuration utility, Version 2.3.0 or lower, sensitive information is transmitted over some web applications in clear text. |
| Delta Industrial Automation CNCSoft ScreenEditor, v1.00.96 and prior. Multiple stack-based buffer overflows can be exploited when a valid user opens a specially crafted, malicious input file. |
| In Moxa EDS-G516E Series firmware, Version 5.2 or lower, the affected products use a weak cryptographic algorithm, which may allow confidential information to be disclosed. |
| VISAM VBASE Editor version 11.5.0.2 and VBASE Web-Remote Module may allow an unauthenticated attacker to discover the cryptographic key from the web server and gain information about the login and the encryption/decryption mechanism, which may be exploited to bypass authentication of the HTML5 HMI web interface. |
| In Moxa EDS-G516E Series firmware, Version 5.2 or lower, sensitive information is transmitted over some web applications in cleartext. |
| In Moxa PT-7528 series firmware, Version 4.0 or lower, and PT-7828 series firmware, Version 3.9 or lower, an attacker can gain access to sensitive information from the web service without authorization. |
| Rockwell Automation MicroLogix 1400 Controllers Series B v21.001 and prior, Series A, all versions, MicroLogix 1100 Controller, all versions, RSLogix 500 Software v12.001 and prior, A remote, unauthenticated attacker can send a request from the RSLogix 500 software to the victim’s MicroLogix controller. The controller will then respond to the client with used password values to authenticate the user on the client-side. This method of authentication may allow an attacker to bypass authentication altogether, disclose sensitive information, or leak credentials. |
| In Moxa PT-7528 series firmware, Version 4.0 or lower, and PT-7828 series firmware, Version 3.9 or lower, the affected products use a weak cryptographic algorithm, which may allow confidential information to be disclosed. |
| In all versions of Omron PLC CJ Series, an attacker can send a series of specific data packets within a short period, causing a service error on the PLC Ethernet module, which in turn causes a PLC service denied result. |
| Rockwell Automation MicroLogix 1400 Controllers Series B v21.001 and prior, Series A, all versions, MicroLogix 1100 Controller, all versions, RSLogix 500 Software v12.001 and prior, The cryptographic function utilized to protect the password in MicroLogix is discoverable. |
| In Moxa PT-7528 series firmware, Version 4.0 or lower, and PT-7828 series firmware, Version 3.9 or lower, the affected products use a hard-coded cryptographic key, which increases the possibility that confidential data can be recovered. |
| In Honeywell WIN-PAK 4.7.2, Web and prior versions, the header injection vulnerability has been identified, which may allow remote code execution. |
| In Moxa EDS-G516E Series firmware, Version 5.2 or lower, the affected products use a hard-coded cryptographic key, increasing the possibility that confidential data can be recovered. |
| In Honeywell WIN-PAK 4.7.2, Web and prior versions, the affected product is vulnerable due to the usage of old jQuery libraries. |
| In Emerson ValveLink v12.0.264 to v13.4.118, a vulnerability in the ValveLink software may allow a local, unprivileged, trusted insider to escalate privileges due to insecure configuration parameters. |
| Honeywell INNCOM INNControl 3 allows workstation users to escalate application user privileges through the modification of local configuration files. |
| In ApexPro Telemetry Server Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 & prior, Clinical Information Center (CIC) Versions 4.X and 5.X, CARESCAPE Central Station (CSCS) Versions 1.X and CARESCAPE Central Station (CSCS) Versions 2.X, the integrated service for keyboard switching of the affected devices could allow attackers to obtain remote keyboard input access without authentication over the network. |