Search Results (320 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2026-4483 1 Moxa 1 Mxgeneralio 2026-04-08 N/A
An exposed IOCTL with an  insufficient access control vulnerability has been identified in the utility, MxGeneralIo, for Moxa’s industrial x86 computers. The affected utility, MxGeneralIo, exposes IOCTL methods that permit direct read and write access to MSR and system memory. A local attacker with high privileges could abuse these interfaces to perform unauthorized operations. Successful exploitation may result in privilege escalation on Windows 7 systems or cause a system crash (BSoD) on Windows 10 and 11 systems, leading to a denial-of-service condition. The vulnerability could slightly affect the confidentiality and integrity of the device, but availability might be heavily impacted. No impact to the subsequent system has been identified.
CVE-2022-41313 1 Moxa 4 Sds-3008, Sds-3008-t, Sds-3008-t Firmware and 1 more 2025-11-04 5.4 Medium
A stored cross-site scripting vulnerability exists in the web application functionality of Moxa SDS-3008 Series Industrial Ethernet Switch 2.1. A specially-crafted HTTP request can lead to arbitrary Javascript execution. An attacker can send an HTTP request to trigger this vulnerability.Form field id="switch_contact"
CVE-2022-41312 1 Moxa 4 Sds-3008, Sds-3008-t, Sds-3008-t Firmware and 1 more 2025-11-04 5.4 Medium
A stored cross-site scripting vulnerability exists in the web application functionality of Moxa SDS-3008 Series Industrial Ethernet Switch 2.1. A specially-crafted HTTP request can lead to arbitrary Javascript execution. An attacker can send an HTTP request to trigger this vulnerability.Form field id="Switch Description", name "switch_description"
CVE-2022-41311 1 Moxa 4 Sds-3008, Sds-3008-t, Sds-3008-t Firmware and 1 more 2025-11-04 5.4 Medium
A stored cross-site scripting vulnerability exists in the web application functionality of Moxa SDS-3008 Series Industrial Ethernet Switch 2.1. A specially-crafted HTTP request can lead to arbitrary Javascript execution. An attacker can send an HTTP request to trigger this vulnerability.Form field id="webLocationMessage_text" name="webLocationMessage_text"
CVE-2016-8718 1 Moxa 2 Awk-3131a, Awk-3131a Firmware 2025-04-20 8.8 High
An exploitable Cross-Site Request Forgery vulnerability exists in the Web Application functionality of Moxa AWK-3131A Wireless Access Point running firmware 1.1. A specially crafted form can trick a client into making an unintentional request to the web server which will be treated as an authentic request.
CVE-2016-8724 1 Moxa 2 Awk-3131a, Awk-3131a Firmware 2025-04-20 5.3 Medium
An exploitable information disclosure vulnerability exists in the serviceAgent functionality of Moxa AWK-3131A Wireless Access Point running firmware 1.1. A specially crafted TCP query will allow an attacker to retrieve potentially sensitive information.
CVE-2016-8719 1 Moxa 2 Awk-3131a, Awk-3131a Firmware 2025-04-20 6.1 Medium
An exploitable reflected Cross-Site Scripting vulnerability exists in the Web Application functionality of Moxa AWK-3131A Wireless Access Point running firmware 1.1. Specially crafted input, in multiple parameters, can cause a malicious scripts to be executed by a victim.
CVE-2016-8712 1 Moxa 2 Awk-3131a, Awk-3131a Firmware 2025-04-20 8.1 High
An exploitable nonce reuse vulnerability exists in the Web Application functionality of Moxa AWK-3131A Wireless AP running firmware 1.1. The device uses one nonce for all session authentication requests and only changes the nonce if the web application has been idle for 300 seconds.
CVE-2016-8716 1 Moxa 2 Awk-3131a, Awk-3131a Firmware 2025-04-20 7.5 High
An exploitable Cleartext Transmission of Password vulnerability exists in the Web Application functionality of Moxa AWK-3131A Wireless Access Point running firmware 1.1. The Change Password functionality of the Web Application transmits the password in cleartext. An attacker capable of intercepting this traffic is able to obtain valid credentials.
CVE-2016-8720 1 Moxa 2 Awk-3131a, Awk-3131a Firmware 2025-04-20 4.3 Medium
An exploitable HTTP Header Injection vulnerability exists in the Web Application functionality of the Moxa AWK-3131A Wireless Access Point running firmware 1.1. A specially crafted HTTP request can inject a payload in the bkpath parameter which will be copied in to Location header of the HTTP response.
CVE-2016-8359 1 Moxa 19 Iologik E1200 Series Firmware, Iologik E1210, Iologik E1211 and 16 more 2025-04-20 6.1 Medium
An issue was discovered in Moxa ioLogik E1210, firmware Version V2.4 and prior, ioLogik E1211, firmware Version V2.3 and prior, ioLogik E1212, firmware Version V2.4 and prior, ioLogik E1213, firmware Version V2.5 and prior, ioLogik E1214, firmware Version V2.4 and prior, ioLogik E1240, firmware Version V2.3 and prior, ioLogik E1241, firmware Version V2.4 and prior, ioLogik E1242, firmware Version V2.4 and prior, ioLogik E1260, firmware Version V2.4 and prior, ioLogik E1262, firmware Version V2.4 and prior, ioLogik E2210, firmware versions prior to V3.13, ioLogik E2212, firmware versions prior to V3.14, ioLogik E2214, firmware versions prior to V3.12, ioLogik E2240, firmware versions prior to V3.12, ioLogik E2242, firmware versions prior to V3.12, ioLogik E2260, firmware versions prior to V3.13, and ioLogik E2262, firmware versions prior to V3.12. The web application fails to sanitize user input, which may allow an attacker to inject script or execute arbitrary code (CROSS-SITE SCRIPTING).
CVE-2016-8372 1 Moxa 19 Iologik E1200 Series Firmware, Iologik E1210, Iologik E1211 and 16 more 2025-04-20 8.1 High
An issue was discovered in Moxa ioLogik E1210, firmware Version V2.4 and prior, ioLogik E1211, firmware Version V2.3 and prior, ioLogik E1212, firmware Version V2.4 and prior, ioLogik E1213, firmware Version V2.5 and prior, ioLogik E1214, firmware Version V2.4 and prior, ioLogik E1240, firmware Version V2.3 and prior, ioLogik E1241, firmware Version V2.4 and prior, ioLogik E1242, firmware Version V2.4 and prior, ioLogik E1260, firmware Version V2.4 and prior, ioLogik E1262, firmware Version V2.4 and prior, ioLogik E2210, firmware versions prior to V3.13, ioLogik E2212, firmware versions prior to V3.14, ioLogik E2214, firmware versions prior to V3.12, ioLogik E2240, firmware versions prior to V3.12, ioLogik E2242, firmware versions prior to V3.12, ioLogik E2260, firmware versions prior to V3.13, and ioLogik E2262, firmware versions prior to V3.12. A password is transmitted in a format that is not sufficiently secure.
CVE-2016-8379 1 Moxa 19 Iologik E1200 Series Firmware, Iologik E1210, Iologik E1211 and 16 more 2025-04-20 8.1 High
An issue was discovered in Moxa ioLogik E1210, firmware Version V2.4 and prior, ioLogik E1211, firmware Version V2.3 and prior, ioLogik E1212, firmware Version V2.4 and prior, ioLogik E1213, firmware Version V2.5 and prior, ioLogik E1214, firmware Version V2.4 and prior, ioLogik E1240, firmware Version V2.3 and prior, ioLogik E1241, firmware Version V2.4 and prior, ioLogik E1242, firmware Version V2.4 and prior, ioLogik E1260, firmware Version V2.4 and prior, ioLogik E1262, firmware Version V2.4 and prior, ioLogik E2210, firmware versions prior to V3.13, ioLogik E2212, firmware versions prior to V3.14, ioLogik E2214, firmware versions prior to V3.12, ioLogik E2240, firmware versions prior to V3.12, ioLogik E2242, firmware versions prior to V3.12, ioLogik E2260, firmware versions prior to V3.13, and ioLogik E2262, firmware versions prior to V3.12. Users are restricted to using short passwords.
CVE-2016-9356 1 Moxa 1 Dacenter 2025-04-20 N/A
An issue was discovered in Moxa DACenter Versions 1.4 and older. The application may suffer from an unquoted search path issue.
CVE-2016-8350 1 Moxa 19 Iologik E1200 Series Firmware, Iologik E1210, Iologik E1211 and 16 more 2025-04-20 6.3 Medium
An issue was discovered in Moxa ioLogik E1210, firmware Version V2.4 and prior, ioLogik E1211, firmware Version V2.3 and prior, ioLogik E1212, firmware Version V2.4 and prior, ioLogik E1213, firmware Version V2.5 and prior, ioLogik E1214, firmware Version V2.4 and prior, ioLogik E1240, firmware Version V2.3 and prior, ioLogik E1241, firmware Version V2.4 and prior, ioLogik E1242, firmware Version V2.4 and prior, ioLogik E1260, firmware Version V2.4 and prior, ioLogik E1262, firmware Version V2.4 and prior, ioLogik E2210, firmware versions prior to V3.13, ioLogik E2212, firmware versions prior to V3.14, ioLogik E2214, firmware versions prior to V3.12, ioLogik E2240, firmware versions prior to V3.12, ioLogik E2242, firmware versions prior to V3.12, ioLogik E2260, firmware versions prior to V3.13, and ioLogik E2262, firmware versions prior to V3.12. The web application may not sufficiently verify whether a request was provided by a valid user (CROSS-SITE REQUEST FORGERY).
CVE-2017-16719 1 Moxa 6 Nport 5110, Nport 5110 Firmware, Nport 5130 and 3 more 2025-04-20 N/A
An Injection issue was discovered in Moxa NPort 5110 Version 2.2, NPort 5110 Version 2.4, NPort 5110 Version 2.6, NPort 5110 Version 2.7, NPort 5130 Version 3.7 and prior, and NPort 5150 Version 3.7 and prior. An attacker may be able to inject packets that could potentially disrupt the availability of the device.
CVE-2016-8723 1 Moxa 2 Awk-3131a, Awk-3131a Firmware 2025-04-20 7.5 High
An exploitable null pointer dereference exists in the Web Application functionality of Moxa AWK-3131A Wireless Access Point running firmware 1.1. Any HTTP GET request not preceded by an '/' will cause a segmentation fault in the web server. An attacker can send any of a multitude of potentially unexpected HTTP get requests to trigger this vulnerability.
CVE-2016-9333 1 Moxa 1 Softcms 2025-04-20 N/A
An issue was discovered in Moxa SoftCMS versions prior to Version 1.6. The SoftCMS Application does not properly sanitize input that may allow a remote attacker access to SoftCMS with administrator's privilege through specially crafted input (SQL INJECTION).
CVE-2016-9371 1 Moxa 51 Nport 5100 Series Firmware, Nport 5100a Series Firmware, Nport 5110 and 48 more 2025-04-20 N/A
An issue was discovered in Moxa NPort 5110 versions prior to 2.6, NPort 5130/5150 Series versions prior to 3.6, NPort 5200 Series versions prior to 2.8, NPort 5400 Series versions prior to 3.11, NPort 5600 Series versions prior to 3.7, NPort 5100A Series & NPort P5150A versions prior to 1.3, NPort 5200A Series versions prior to 1.3, NPort 5150AI-M12 Series versions prior to 1.2, NPort 5250AI-M12 Series versions prior to 1.2, NPort 5450AI-M12 Series versions prior to 1.2, NPort 5600-8-DT Series versions prior to 2.4, NPort 5600-8-DTL Series versions prior to 2.4, NPort 6x50 Series versions prior to 1.13.11, NPort IA5450A versions prior to v1.4. User-controlled input is not neutralized before being output to web page (CROSS-SITE SCRIPTING).
CVE-2016-8726 1 Moxa 2 Awk-3131a, Awk-3131a Firmware 2025-04-20 7.5 High
An exploitable null pointer dereference vulnerability exists in the Web Application /forms/web_runScript iw_filename functionality of Moxa AWK-3131A Wireless Access Point running firmware 1.1. An HTTP POST request with a blank line in the header will cause a segmentation fault in the web server.