| Successful exploitation of this vulnerability could allow an unauthorized user to access sensitive data. |
| An unauthenticated remote user could exploit a potential integer overflow condition in the exacqVision Server with a specially crafted script and cause denial-of-service condition. |
| Under certain configurations an unauthenticated remote user could be given access to credentials stored in the exacqVision Server. |
| A vulnerability in versions 10.1 through 10.5 of Johnson Controls CEM Systems AC2000 allows a remote attacker to access to the system without adequate authorization. This issue affects: Johnson Controls CEM Systems AC2000 10.1; 10.2; 10.3; 10.4; 10.5. |
| The KT-1 door controller is susceptible to replay or man-in-the-middle attacks where an attacker can record and replay TCP packets. This issue affects Johnson Controls KT-1 all versions up to and including 3.01 |
| Successful exploitation of this vulnerability could give an authenticated Facility Explorer SNC Series Supervisory Controller (F4-SNC) user an unintended level of access to the controller’s file system, allowing them to access or modify system files by sending specifically crafted web messages to the F4-SNC. |
| An insecure client auto update feature in C-CURE 9000 can allow remote execution of lower privileged Windows programs. |
| exacqVision Web Service 21.03 does not sufficiently validate, filter, escape, and/or encode user-controllable input before it is placed in output that is used as a web page that is served to other users. |
| exacqVision Enterprise Manager 20.12 does not sufficiently validate, filter, escape, and/or encode user-controllable input before it is placed in output that is used as a web page that is served to other users. |
| Successful exploitation of this vulnerability could give an authenticated Metasys user an unintended level of access to the server file system, allowing them to access or modify system files by sending specifically crafted web messages to the Metasys system. This issue affects: Johnson Controls Metasys version 11.0 and prior versions. |
| A vulnerability in exacqVision Web Service 20.12.2.0 and prior could allow an unauthenticated attacker to view system-level information about the exacqVision Web Service and the operating system. |
| Path Traversal vulnerability exists in Metasys Reporting Engine (MRE) Web Services which could allow a remote unauthenticated attacker to access and download arbitrary files from the system. |
| A vulnerability in specified versions of American Dynamics victor Web Client and Software House C•CURE Web Client could allow an unauthenticated attacker on the network to create and sign their own JSON Web Token and use it to execute an HTTP API Method without the need for valid authentication/authorization. Under certain circumstances, this could be used by an attacker to impact system availability by conducting a Denial of Service attack. |
| A vulnerability in specified versions of American Dynamics victor Web Client and Software House CCURE Web Client could allow a remote unauthenticated attacker on the network to delete arbitrary files on the system or render the system unusable by conducting a Denial of Service attack. |
| A vulnerability exists that could allow the execution of unauthorized code or operating system commands on systems running exacqVision Web Service versions 20.06.3.0 and prior and exacqVision Enterprise Manager versions 20.06.4.0 and prior. An attacker with administrative privileges could potentially download and run a malicious executable that could allow OS command injection on the system. |
| A vulnerability in all versions of Kantech EntraPass Editions could potentially allow an authorized low-privileged user to gain full system-level privileges by replacing critical files with specifically crafted files. |
| During installation or upgrade to Software House C•CURE 9000 v2.70 and American Dynamics victor Video Management System v5.2, the credentials of the user used to perform the installation or upgrade are logged in a file. The install log file persists after the installation. |
| XXE vulnerability exists in the Metasys family of product Web Services which has the potential to facilitate DoS attacks or harvesting of ASCII server files. This affects Johnson Controls' Metasys Application and Data Server (ADS, ADS-Lite) versions 10.1 and prior; Metasys Extended Application and Data Server (ADX) versions 10.1 and prior; Metasys Open Data Server (ODS) versions 10.1 and prior; Metasys Open Application Server (OAS) version 10.1; Metasys Network Automation Engine (NAE55 only) versions 9.0.1, 9.0.2, 9.0.3, 9.0.5, 9.0.6; Metasys Network Integration Engine (NIE55/NIE59) versions 9.0.1, 9.0.2, 9.0.3, 9.0.5, 9.0.6; Metasys NAE85 and NIE85 versions 10.1 and prior; Metasys LonWorks Control Server (LCS) versions 10.1 and prior; Metasys System Configuration Tool (SCT) versions 13.2 and prior; Metasys Smoke Control Network Automation Engine (NAE55, UL 864 UUKL/ORD-C100-13 UUKLC 10th Edition Listed) version 8.1. |
| Metasys® ADS/ADX servers and NAE/NIE/NCE engines prior to 9.0 make use of a hardcoded RC2 key for certain encryption operations involving the Site Management Portal (SMP). |