| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| RAD SecFlow-2 devices with Hardware 0202, Firmware 4.1.01.63, and U-Boot 2010.12 allow URIs beginning with /.. for Directory Traversal, as demonstrated by reading /etc/shadow. |
| This vulnerability exists in ZKTeco WL20 due to storage of Wi-Fi credentials, configuration data and system data in plaintext within the device firmware. An attacker with physical access could exploit this vulnerability by extracting the firmware and reverse engineer the binary data to access the plaintext sensitive data stored in the targeted device.
Successful exploitation of this vulnerability could allow the attacker to gain unauthorized network access, retrieve and manipulate data on the targeted device. |
| A privilege escalation vulnerability was discovered that could allow a valid, authenticated LXCA user to escalate their permissions for a connected XCC instance when using LXCA as a Single Sign On (SSO) provider for XCC instances. |
| A vulnerability was detected in LionCoders SalePro POS up to 5.5.0. This issue affects some unknown processing of the component Login. Performing manipulation results in cleartext transmission of sensitive information. The attack can be initiated remotely. The attack is considered to have high complexity. The exploitability is assessed as difficult. The exploit is now public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. |
| Electrolink transmitters store credentials in clear-text. Use of these credentials could allow an attacker to access the system. |
| This vulnerability exists in Digisol DG-GR6821AC Router due to cleartext transmission of credentials in its web management interface. A remote attacker could exploit this vulnerability by intercepting the network traffic and capturing cleartext credentials.
Successful exploitation of this vulnerability could allow the attacker to gain unauthorized access to the targeted device. |
| ToolHive is a utility designed to simplify the deployment and management of Model Context Protocol (MCP) servers. Due to the ordering of code used to start an MCP server container, versions of ToolHive prior to 0.0.33 inadvertently store secrets in the run config files which are used to restart stopped containers. This means that an attacker who has access to the home folder of the user who starts the MCP server can read secrets without needing access to the secrets store itself. This only applies to secrets which were used in containers whose run configs exist at a point in time - other secrets remaining inaccessible. ToolHive 0.0.33 fixes the issue. Some workarounds are available. Stop and delete any running MCP servers, or manually remove any runconfigs from `$HOME/Library/Application Support/toolhive/runconfigs/` (macOS) or `$HOME/.state/toolhive/runconfigs/` (Linux). |
| An issue was discovered on Marbella KR8s Dashcam FF 2.0.8 devices. When a new SD card is inserted into the dashcam, the existing password is written onto the SD card in cleartext automatically. An attacker with temporary access to the dashcam can switch the SD card to steal this password. |
| This vulnerability exists in the Tinxy smart devices due to storage of credentials in plaintext within the device firmware. An attacker with physical access could exploit this by extracting the firmware and analyzing the binary data to obtain the plaintext credentials stored on the vulnerable device. |
| Forever KidsWatch Call Me KW-50 R36_YDR_A3PW_GM7S_V1.0_2019_07_15_16.19.24_cob_h suffers from Cleartext Transmission of Sensitive Information due to lack of encryption in device-server communication. |
| With physical access to the device and enough time an attacker can desolder the flash memory, modify it and then reinstall it because of missing encryption. Thus, essential files, such as "/etc/passwd", as well as stored certificates, cryptographic keys, stored PINs and so on can be modified and read, in order to gain SSH root access on the Linux-based K7 model. On the Windows CE based K5 model, the password for the Access Manager can additionally be read in plain text from the stored SQLite database. |
| On Arista CloudVision Appliance (CVA) affected releases running on appliances that support hardware disk encryption (DCA-350E-CV only), the disk encryption might not be successfully performed. This results in the disks remaining unsecured and data on them |
| Sensitive data could be exposed to non- privileged users in a configuration file. Local access to the computer with a low- privileged account is required to access the configuration file containing the sensitive data. |
| Emerson ValveLink Products store
sensitive information in cleartext within a resource that might be accessible to another control sphere. |
| next-forge is a Next.js project boilerplate for modern web application. The BASEHUB_TOKEN commited in apps/web/.env.example. Users should avoid use of this token and should remove any access it may have in their systems. |
| Puncia is the Official CLI utility for Subdomain Center & Exploit Observer. `API_URLS` is utilizing HTTP instead of HTTPS for communication that can lead to issues like Eavesdropping, Data Tampering, Unauthorized Data Access & MITM Attacks. This issue has been addressed in release version 0.21 by using https rather than http connections. All users are advised to upgrade. There is no known workarounds for this vulnerability.
|
| Using the AES-128-CCM algorithm for IPSec on certain Palo Alto Networks PAN-OS® firewalls (PA-7500, PA-5400, PA-5400f, PA-3400, PA-1600, PA-1400, and PA-400 Series) leads to unencrypted data transfer to devices that are connected to the PAN-OS firewall through IPSec.
This issue does not affect Cloud NGFWs, Prisma® Access instances, or PAN-OS VM-Series firewalls.
NOTE: The AES-128-CCM encryption algorithm is not recommended for use. |
| The web server of the device performs exchanges of sensitive information in clear text through an insecure protocol. |
| The Pixmeo Osirix MD Web Portal sends credential information without encryption, which could allow an attacker to steal credentials. |
| A vulnerability was found in Ruijie EG306MG 3.0(1)B11P309. It has been rated as problematic. This issue affects some unknown processing of the file /etc/strongswan.conf of the component strongSwan. The manipulation of the argument i_dont_care_about_security_and_use_aggressive_mode_psk leads to missing encryption of sensitive data. The attack may be initiated remotely. The complexity of an attack is rather high. The exploitation is known to be difficult. The vendor was contacted early about this disclosure but did not respond in any way. |