Search Results (4580 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2025-4394 2026-04-15 6.8 Medium
Medtronic MyCareLink Patient Monitor uses an unencrypted filesystem on internal storage, which allows an attacker with physical access to read and modify files. This issue affects MyCareLink Patient Monitor models 24950 and 24952: before June 25, 2025
CVE-2024-36426 1 Targit 1 Decision Suite 23.2.15007.0 2026-04-15 7.5 High
In TARGIT Decision Suite 23.2.15007.0 before Autumn 2023, the session token is part of the URL and may be sent in a cleartext HTTP session.
CVE-2025-2909 2026-04-15 N/A
The lack of encryption in the DuoxMe (formerly Blue) application binary in versions prior to 3.3.1 for iOS devices allows an attacker to gain unauthorised access to the application code and discover sensitive information.
CVE-2025-10641 1 Efficientlab 1 Workexaminer Professional 2026-04-15 7.1 High
All WorkExaminer Professional traffic between monitoring client, console and server is transmitted as plain text. This allows an attacker with access to the network to read the transmitted sensitive data. An attacker can also freely modify the data on the wire. The monitoring clients transmit their data to the server using the unencrypted FTP. Clients connect to the FTP server on port 12304 and transmit the data unencrypted. In addition, all traffic between the console client and the server at port 12306 is unencrypted.
CVE-2025-10776 1 Lioncoders 1 Salepro Pos 2026-04-15 3.7 Low
A vulnerability was detected in LionCoders SalePro POS up to 5.5.0. This issue affects some unknown processing of the component Login. Performing manipulation results in cleartext transmission of sensitive information. The attack can be initiated remotely. The attack is considered to have high complexity. The exploitability is assessed as difficult. The exploit is now public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2023-49341 2026-04-15 7.5 High
An issue was discovered in Newland Nquire 1000 Interactive Kiosk version NQ1000-II_G_V1.00.011, allows remote attackers to obtain sensitive information via cleartext credential storage in backup.htm component.
CVE-2025-0631 2026-04-15 N/A
A Credential Exposure Vulnerability exists in the above-mentioned product and version. The vulnerability is due to using HTTP resulting in credentials being sent in clear text.
CVE-2025-62765 1 General Industrial Controls 1 Lynx+ Gateway 2026-04-15 7.5 High
General Industrial Controls Lynx+ Gateway is vulnerable to a cleartext transmission vulnerability that could allow an attacker to observe network traffic to obtain sensitive information, including plaintext credentials.
CVE-2024-12094 1 Mogify Infotech 1 Tinxy Mobile App 2026-04-15 N/A
This vulnerability exists in the Tinxy mobile app due to storage of logged-in user information in plaintext on the device database. An attacker with physical access to the rooted device could exploit this vulnerability by accessing its database leading to unauthorized access of user information such as username, email address and mobile number. Note: To exploit this vulnerability, the device must be rooted/jailbroken.
CVE-2025-53758 2026-04-15 N/A
This vulnerability exists in Digisol DG-GR6821AC Router due to use of default admin credentials at its web management interface. An attacker with physical access could exploit this vulnerability by extracting the firmware and reverse engineer the binary data to access the hardcoded default credentials stored in the firmware of the targeted device. Successful exploitation of this vulnerability could allow the attacker to gain unauthorized access to the targeted device.
CVE-2025-41647 2026-04-15 5.5 Medium
A local, low-privileged attacker can learn the password of the connected controller in PLC Designer V4 due to an incorrect implementation that results in the password being displayed in plain text under special conditions.
CVE-2025-40753 1 Siemens 2 Q100, Q200 2026-04-15 6.2 Medium
A vulnerability has been identified in POWER METER SICAM Q100 (7KG9501-0AA01-0AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q100 (7KG9501-0AA01-2AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q100 (7KG9501-0AA31-0AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q100 (7KG9501-0AA31-2AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q200 family (All versions >= V2.70 < V2.80). Affected devices export the password for the SMTP account as plain text in the Configuration File. This could allow an authenticated local attacker to extract it and use the configured SMTP service for arbitrary purposes.
CVE-2024-4540 1 Redhat 3 Build Keycloak, Red Hat Single Sign On, Rhosemc 2026-04-15 7.5 High
A flaw was found in Keycloak in OAuth 2.0 Pushed Authorization Requests (PAR). Client-provided parameters were found to be included in plain text in the KC_RESTART cookie returned by the authorization server's HTTP response to a `request_uri` authorization request, possibly leading to an information disclosure vulnerability.
CVE-2026-23662 1 Microsoft 1 Azure Iot Explorer 2026-04-14 7.5 High
Missing authentication for critical function in Azure IoT Explorer allows an unauthorized attacker to disclose information over a network.
CVE-2026-23661 1 Microsoft 1 Azure Iot Explorer 2026-04-14 7.5 High
Cleartext transmission of sensitive information in Azure IoT Explorer allows an unauthorized attacker to disclose information over a network.
CVE-2026-34833 1 Bulwarkmail 1 Webmail 2026-04-10 7.5 High
Bulwark Webmail is a self-hosted webmail client for Stalwart Mail Server. Prior to version 1.4.10, the GET /api/auth/session endpoint previously included the user's plaintext password in the JSON response. This exposed credentials to browser logs, local caches, and network proxie. This issue has been patched in version 1.4.10.
CVE-2012-5562 1 Redhat 2 Network Proxy, Satellite 2026-04-09 8.6 High
A flaw was found in rhn-proxy. This vulnerability may allow the rhn-proxy to transmit user credentials in clear-text when it accesses RHN Satellite. This could lead to information disclosure, where sensitive authentication details are exposed to unauthorized parties.
CVE-2025-14815 2 Mitsubishi, Mitsubishielectric 9 Analytix, Gb, Genesis and 6 more 2026-04-09 N/A
Cleartext Storage of Sensitive Information vulnerability in Mitsubishi Electric GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric MobileHMI versions 10.97.3 and prior, Mitsubishi Electric Hyper Historian versions 10.97.3 and prior, Mitsubishi Electric AnalytiX versions 10.97.3 and prior, Mitsubishi Electric GENESIS versions 11.02 and prior, Mitsubishi Electric MC Works64 all versions, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions MobileHMI versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions Hyper Historian versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions AnalytiX versions 10.97.3 and prior, and Mitsubishi Electric Iconics Digital Solutions GENESIS versions 11.02 and prior allows a local attacker to disclose the SQL Server credentials stored in plaintext within the local SQLite file by exploiting this vulnerability, when the local caching feature using SQLite is enabled and SQL authentication is used for the SQL Server authentication. As a result, the unauthorized attacker could access the SQL Server and disclose, tamper with, or destroy data on the server, potentially cause a denial-of-service (DoS) condition on the system.
CVE-2025-14816 1 Mitsubishielectric 7 Analytix, Genesis, Genesis64 and 4 more 2026-04-09 N/A
Cleartext Storage of Sensitive Information in GUI vulnerability in Mitsubishi Electric GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric MobileHMI versions 10.97.3 and prior, Mitsubishi Electric Hyper Historian versions 10.97.3 and prior, Mitsubishi Electric AnalytiX versions 10.97.3 and prior, Mitsubishi Electric GENESIS versions 11.02 and prior, Mitsubishi Electric MC Works64 all versions, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions MobileHMI versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions Hyper Historian versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions AnalytiX versions 10.97.3 and prior, and Mitsubishi Electric Iconics Digital Solutions GENESIS versions 11.02 and prior allows a local attacker to disclose the SQL Server credentials displayed in plain text in the GUI of the Hyper Historian Splitter feature by exploiting this vulnerability, when SQL authentication is used for the SQL Server authentication. As a result, the unauthorized attacker could access the SQL Server and disclose, tamper with, or destroy data on the server, potentially cause a denial-of-service (DoS) condition on the system.
CVE-2026-4820 1 Ibm 1 Maximo Application Suite 2026-04-08 4.3 Medium
IBM Maximo Application Suite 9.1, 9.0, 8.11, and 8.10 does not set the secure attribute on authorization tokens or session cookies. Attackers may be able to get the cookie values by sending a http:// link to a user or by planting this link in a site the user goes to. The cookie will be sent to the insecure link and the attacker can then obtain the cookie value by snooping the traffic.