Search

Search Results (327364 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2026-22600 1 Openproject 1 Openproject 2026-01-13 9.1 Critical
OpenProject is an open-source, web-based project management software. A Local File Read (LFR) vulnerability exists in the work package PDF export functionality of OpenProject prior to version 16.6.4. By uploading a specially crafted SVG file (disguised as a PNG) as a work package attachment, an attacker can exploit the backend image processing engine (ImageMagick). When the work package is exported to PDF, the backend attempts to resize the image, triggering the ImageMagick text: coder. This allows an attacker to read arbitrary local files that the application user has permissions to access (e.g., /etc/passwd, all project configuration files, private project data, etc.). The attack requires permissions to upload attachments to a container that can be exported to PDF, such as a work package. The issue has been patched in version 16.6.4. Those who are unable to upgrade may apply the patch manually.
CVE-2026-22602 1 Openproject 1 Openproject 2026-01-13 3.5 Low
OpenProject is an open-source, web-based project management software. Prior to version 16.6.2, a low‑privileged logged-in user can view the full names of other users. Since user IDs are assigned sequentially and predictably (e.g., 1 to 1000), an attacker can extract a complete list of all users’ full names by iterating through these URLs. The same behavior can also be reproduced via the OpenProject API, allowing automated retrieval of full names through the API as well. This issue has been patched in version 16.6.2. Those who are unable to upgrade may apply the patch manually.
CVE-2026-22603 1 Openproject 1 Openproject 2026-01-13 N/A
OpenProject is an open-source, web-based project management software. Prior to version 16.6.2, OpenProject’s unauthenticated password-change endpoint (/account/change_password) was not protected by the same brute-force safeguards that apply to the normal login form. In affected versions, an attacker who can guess or enumerate user IDs can send unlimited password-change requests for a given account without triggering lockout or other rate-limiting controls. This allows automated password-guessing (e.g., with wordlists of common passwords) against valid accounts. Successful guessing results in full account compromise for the targeted user and, depending on that user’s role, can lead to further privilege escalation inside the application. This issue has been patched in version 16.6.2. Those who are unable to upgrade may apply the patch manually.
CVE-2026-22605 1 Openproject 1 Openproject 2026-01-13 4.3 Medium
OpenProject is an open-source, web-based project management software. OpenProject versions prior to version 16.6.3, allowed users with the View Meetings permission on any project, to access meeting details of meetings that belonged to projects, the user does not have access to. This issue has been patched in version 16.6.3.
CVE-2026-22606 1 Trailofbits 1 Fickling 2026-01-13 N/A
Fickling is a Python pickling decompiler and static analyzer. Fickling versions up to and including 0.1.6 do not treat Python’s runpy module as unsafe. Because of this, a malicious pickle that uses runpy.run_path() or runpy.run_module() is classified as SUSPICIOUS instead of OVERTLY_MALICIOUS. If a user relies on Fickling’s output to decide whether a pickle is safe to deserialize, this misclassification can lead them to execute attacker-controlled code on their system. This affects any workflow or product that uses Fickling as a security gate for pickle deserialization. This issue has been patched in version 0.1.7.
CVE-2026-22607 1 Trailofbits 1 Fickling 2026-01-13 N/A
Fickling is a Python pickling decompiler and static analyzer. Fickling versions up to and including 0.1.6 do not treat Python's cProfile module as unsafe. Because of this, a malicious pickle that uses cProfile.run() is classified as SUSPICIOUS instead of OVERTLY_MALICIOUS. If a user relies on Fickling's output to decide whether a pickle is safe to deserialize, this misclassification can lead them to execute attacker-controlled code on their system. This affects any workflow or product that uses Fickling as a security gate for pickle deserialization. This issue has been patched in version 0.1.7.
CVE-2026-22609 1 Trailofbits 1 Fickling 2026-01-13 N/A
Fickling is a Python pickling decompiler and static analyzer. Prior to version 0.1.7, the unsafe_imports() method in Fickling's static analyzer fails to flag several high-risk Python modules that can be used for arbitrary code execution. Malicious pickles importing these modules will not be detected as unsafe, allowing attackers to bypass Fickling's primary static safety checks. This issue has been patched in version 0.1.7.
CVE-2022-50796 1 Sound4 21 Big Voice2, Big Voice2 Firmware, Big Voice4 and 18 more 2026-01-13 7.5 High
SOUND4 IMPACT/FIRST/PULSE/Eco <=2.x contains an unauthenticated remote code execution vulnerability in the firmware upload functionality with path traversal flaw. Attackers can exploit the upload.cgi script to write malicious files to the system with www-data permissions, enabling unauthorized access and code execution.
CVE-2025-40569 2026-01-13 4.8 Medium
A vulnerability has been identified in RUGGEDCOM RST2428P (6GK6242-6PA00) (All versions < V3.2), SCALANCE XCH328 (6GK5328-4TS01-2EC2) (All versions < V3.2), SCALANCE XCM324 (6GK5324-8TS01-2AC2) (All versions < V3.2), SCALANCE XCM328 (6GK5328-4TS01-2AC2) (All versions < V3.2), SCALANCE XCM332 (6GK5332-0GA01-2AC2) (All versions < V3.2), SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3) (All versions < V3.2), SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3) (All versions < V3.2), SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3) (All versions < V3.2), SCALANCE XRM334 (230V AC, 2x10G, 24xSFP, 8xSFP+) (6GK5334-5TS01-3AR3) (All versions < V3.2), SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3) (All versions < V3.2), SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3) (All versions < V3.2), SCALANCE XRM334 (24V DC, 2x10G, 24xSFP, 8xSFP+) (6GK5334-5TS01-2AR3) (All versions < V3.2), SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3) (All versions < V3.2), SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3) (All versions < V3.2), SCALANCE XRM334 (2x230V AC, 2x10G, 24xSFP, 8xSFP+) (6GK5334-5TS01-4AR3) (All versions < V3.2). The "Load Configuration from Local PC" functionality in the web interface of affected products contains a race condition vulnerability. This could allow an authenticated remote attacker to make the affected product load an attacker controlled configuration instead of the legitimate one. Successful exploitation requires that a legitimate administrator invokes the functionality and the attacker wins the race condition.
CVE-2025-40568 2026-01-13 4.3 Medium
A vulnerability has been identified in RUGGEDCOM RST2428P (6GK6242-6PA00) (All versions < V3.2), SCALANCE XCH328 (6GK5328-4TS01-2EC2) (All versions < V3.2), SCALANCE XCM324 (6GK5324-8TS01-2AC2) (All versions < V3.2), SCALANCE XCM328 (6GK5328-4TS01-2AC2) (All versions < V3.2), SCALANCE XCM332 (6GK5332-0GA01-2AC2) (All versions < V3.2), SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3) (All versions < V3.2), SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3) (All versions < V3.2), SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3) (All versions < V3.2), SCALANCE XRM334 (230V AC, 2x10G, 24xSFP, 8xSFP+) (6GK5334-5TS01-3AR3) (All versions < V3.2), SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3) (All versions < V3.2), SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3) (All versions < V3.2), SCALANCE XRM334 (24V DC, 2x10G, 24xSFP, 8xSFP+) (6GK5334-5TS01-2AR3) (All versions < V3.2), SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3) (All versions < V3.2), SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3) (All versions < V3.2), SCALANCE XRM334 (2x230V AC, 2x10G, 24xSFP, 8xSFP+) (6GK5334-5TS01-4AR3) (All versions < V3.2). An internal session termination functionality in the web interface of affected products contains an incorrect authorization check vulnerability. This could allow an authenticated remote attacker with "guest" role to terminate legitimate users' sessions.
CVE-2025-40567 2026-01-13 6.5 Medium
A vulnerability has been identified in RUGGEDCOM RST2428P (6GK6242-6PA00) (All versions < V3.2), SCALANCE XCH328 (6GK5328-4TS01-2EC2) (All versions < V3.2), SCALANCE XCM324 (6GK5324-8TS01-2AC2) (All versions < V3.2), SCALANCE XCM328 (6GK5328-4TS01-2AC2) (All versions < V3.2), SCALANCE XCM332 (6GK5332-0GA01-2AC2) (All versions < V3.2), SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3) (All versions < V3.2), SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3) (All versions < V3.2), SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3) (All versions < V3.2), SCALANCE XRM334 (230V AC, 2x10G, 24xSFP, 8xSFP+) (6GK5334-5TS01-3AR3) (All versions < V3.2), SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3) (All versions < V3.2), SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3) (All versions < V3.2), SCALANCE XRM334 (24V DC, 2x10G, 24xSFP, 8xSFP+) (6GK5334-5TS01-2AR3) (All versions < V3.2), SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3) (All versions < V3.2), SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3) (All versions < V3.2), SCALANCE XRM334 (2x230V AC, 2x10G, 24xSFP, 8xSFP+) (6GK5334-5TS01-4AR3) (All versions < V3.2). The "Load Rollback" functionality in the web interface of affected products contains an incorrect authorization check vulnerability. This could allow an authenticated remote attacker with "guest" role to make the affected product roll back configuration changes made by privileged users.
CVE-2024-56840 1 Siemens 2 Ruggedcom Rox Ii, Ruggedcom Rox Ii Firmware 2026-01-13 7.2 High
A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.17.0), RUGGEDCOM ROX MX5000RE (All versions < V2.17.0), RUGGEDCOM ROX RX1400 (All versions < V2.17.0), RUGGEDCOM ROX RX1500 (All versions < V2.17.0), RUGGEDCOM ROX RX1501 (All versions < V2.17.0), RUGGEDCOM ROX RX1510 (All versions < V2.17.0), RUGGEDCOM ROX RX1511 (All versions < V2.17.0), RUGGEDCOM ROX RX1512 (All versions < V2.17.0), RUGGEDCOM ROX RX1524 (All versions < V2.17.0), RUGGEDCOM ROX RX1536 (All versions < V2.17.0), RUGGEDCOM ROX RX5000 (All versions < V2.17.0). Under certain conditions, IPsec may allow code injection in the affected device. An attacker could leverage this scenario to execute arbitrary code as root user.
CVE-2024-56839 1 Siemens 2 Ruggedcom Rox Ii, Ruggedcom Rox Ii Firmware 2026-01-13 7.2 High
A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.17.0), RUGGEDCOM ROX MX5000RE (All versions < V2.17.0), RUGGEDCOM ROX RX1400 (All versions < V2.17.0), RUGGEDCOM ROX RX1500 (All versions < V2.17.0), RUGGEDCOM ROX RX1501 (All versions < V2.17.0), RUGGEDCOM ROX RX1510 (All versions < V2.17.0), RUGGEDCOM ROX RX1511 (All versions < V2.17.0), RUGGEDCOM ROX RX1512 (All versions < V2.17.0), RUGGEDCOM ROX RX1524 (All versions < V2.17.0), RUGGEDCOM ROX RX1536 (All versions < V2.17.0), RUGGEDCOM ROX RX5000 (All versions < V2.17.0). Code injection can be achieved when the affected device is using VRF (Virtual Routing and Forwarding). An attacker could leverage this scenario to execute arbitrary code as root user.
CVE-2024-56838 1 Siemens 2 Ruggedcom Rox Ii, Ruggedcom Rox Ii Firmware 2026-01-13 7.2 High
A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.17.0), RUGGEDCOM ROX MX5000RE (All versions < V2.17.0), RUGGEDCOM ROX RX1400 (All versions < V2.17.0), RUGGEDCOM ROX RX1500 (All versions < V2.17.0), RUGGEDCOM ROX RX1501 (All versions < V2.17.0), RUGGEDCOM ROX RX1510 (All versions < V2.17.0), RUGGEDCOM ROX RX1511 (All versions < V2.17.0), RUGGEDCOM ROX RX1512 (All versions < V2.17.0), RUGGEDCOM ROX RX1524 (All versions < V2.17.0), RUGGEDCOM ROX RX1536 (All versions < V2.17.0), RUGGEDCOM ROX RX5000 (All versions < V2.17.0). The SCEP client available in the affected device for secure certificate enrollment lacks validation of multiple fields. An attacker could leverage this scenario to execute arbitrary code as root user.
CVE-2024-56837 1 Siemens 2 Ruggedcom Rox Ii, Ruggedcom Rox Ii Firmware 2026-01-13 7.2 High
A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.17.0), RUGGEDCOM ROX MX5000RE (All versions < V2.17.0), RUGGEDCOM ROX RX1400 (All versions < V2.17.0), RUGGEDCOM ROX RX1500 (All versions < V2.17.0), RUGGEDCOM ROX RX1501 (All versions < V2.17.0), RUGGEDCOM ROX RX1510 (All versions < V2.17.0), RUGGEDCOM ROX RX1511 (All versions < V2.17.0), RUGGEDCOM ROX RX1512 (All versions < V2.17.0), RUGGEDCOM ROX RX1524 (All versions < V2.17.0), RUGGEDCOM ROX RX1536 (All versions < V2.17.0), RUGGEDCOM ROX RX5000 (All versions < V2.17.0). Due to the insufficient validation during the installation and load of certain configuration files of the affected device, an attacker could spawn a reverse shell and gain root access on the affected system.
CVE-2024-56836 1 Siemens 2 Ruggedcom Rox Ii, Ruggedcom Rox Ii Firmware 2026-01-13 7.5 High
A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.17.0), RUGGEDCOM ROX MX5000RE (All versions < V2.17.0), RUGGEDCOM ROX RX1400 (All versions < V2.17.0), RUGGEDCOM ROX RX1500 (All versions < V2.17.0), RUGGEDCOM ROX RX1501 (All versions < V2.17.0), RUGGEDCOM ROX RX1510 (All versions < V2.17.0), RUGGEDCOM ROX RX1511 (All versions < V2.17.0), RUGGEDCOM ROX RX1512 (All versions < V2.17.0), RUGGEDCOM ROX RX1524 (All versions < V2.17.0), RUGGEDCOM ROX RX1536 (All versions < V2.17.0), RUGGEDCOM ROX RX5000 (All versions < V2.17.0). During the Dynamic DNS configuration of the affected product it is possible to inject additional configuration parameters. Under certain circumstances, an attacker could leverage this vulnerability to spawn a reverse shell and gain root access on the affected system.
CVE-2024-56835 1 Siemens 2 Ruggedcom Rox Ii, Ruggedcom Rox Ii Firmware 2026-01-13 8.8 High
A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.17.0), RUGGEDCOM ROX MX5000RE (All versions < V2.17.0), RUGGEDCOM ROX RX1400 (All versions < V2.17.0), RUGGEDCOM ROX RX1500 (All versions < V2.17.0), RUGGEDCOM ROX RX1501 (All versions < V2.17.0), RUGGEDCOM ROX RX1510 (All versions < V2.17.0), RUGGEDCOM ROX RX1511 (All versions < V2.17.0), RUGGEDCOM ROX RX1512 (All versions < V2.17.0), RUGGEDCOM ROX RX1524 (All versions < V2.17.0), RUGGEDCOM ROX RX1536 (All versions < V2.17.0), RUGGEDCOM ROX RX5000 (All versions < V2.17.0). The DHCP Server configuration file of the affected products is subject to code injection. An attacker could leverage this vulnerability to spawn a reverse shell and gain root access on the affected system.
CVE-2024-49775 2026-01-13 9.8 Critical
A vulnerability has been identified in Opcenter Execution Foundation (All versions < V2501.0001), Opcenter Intelligence (All versions < V2501.0001), Opcenter Quality (All versions < V2512), Opcenter RDnL (All versions < V2410), SIMATIC PCS neo V4.0 (All versions), SIMATIC PCS neo V4.1 (All versions < V4.1 Update 3), SIMATIC PCS neo V5.0 (All versions < V5.0 Update 1), SINEC NMS (All versions if operated in conjunction with UMC < V2.15), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions), Totally Integrated Automation Portal (TIA Portal) V18 (All versions), Totally Integrated Automation Portal (TIA Portal) V19 (All versions). Affected products contain a heap-based buffer overflow vulnerability in the integrated UMC component. This could allow an unauthenticated remote attacker to execute arbitrary code.
CVE-2025-30033 2026-01-13 7.8 High
The affected setup component is vulnerable to DLL hijacking. This could allow an attacker to execute arbitrary code when a legitimate user installs an application that uses the affected setup component.
CVE-2025-56558 1 Dyson 1 App 2026-01-13 3 Low
The Dyson MQTT server (2022 and possibly later) allows publications and subscriptions by a client that has the correct values of AWS_ACCESS_KEY_ID, AWS_SECRET_ACCESS_KEY, AWS_SESSION_TOKEN, and device serial number, even if a device (such as a Pure Hot+Cool device) has been removed and is not visible in the supported MyDyson app. This could allow an unexpected actor to obtain control and set the room temperature (up to 37 Celsius) if ownership of the device is transferred without wiping the device. NOTE: the Supplier's position is that this is a potential vulnerability that dates back 4 years ago in 2022 and "we are unable to replicate that anymore." Based on the submitted report, in order to leverage this issue, an attacker needs to own a Dyson device with full privileges, sniff for the AWS credentials, and then transfer ownership of that Dyson device to the victim. Even if these steps were successfully accomplished, the attacker only acquires the ability to configure the Dyson device within its safe operating range, and does not acquire the ability to execute code on the device or obtain sensitive information.