| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| A vulnerability, which was classified as problematic, has been found in FNKvision FNK-GU2 up to 40.1.7. Affected by this issue is some unknown functionality of the file /rom/wpa_supplicant.conf. The manipulation leads to cleartext storage of sensitive information. It is possible to launch the attack on the physical device. The complexity of an attack is rather high. The exploitation is known to be difficult. The exploit has been disclosed to the public and may be used. |
| A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions), SIPROTEC 5 6MD85 (CP200) (All versions), SIPROTEC 5 6MD85 (CP300) (All versions), SIPROTEC 5 6MD86 (CP200) (All versions), SIPROTEC 5 6MD86 (CP300) (All versions), SIPROTEC 5 6MD89 (CP300) (All versions), SIPROTEC 5 6MU85 (CP300) (All versions), SIPROTEC 5 7KE85 (CP200) (All versions), SIPROTEC 5 7KE85 (CP300) (All versions), SIPROTEC 5 7SA82 (CP100) (All versions), SIPROTEC 5 7SA82 (CP150) (All versions), SIPROTEC 5 7SA86 (CP200) (All versions), SIPROTEC 5 7SA86 (CP300) (All versions), SIPROTEC 5 7SA87 (CP200) (All versions), SIPROTEC 5 7SA87 (CP300) (All versions), SIPROTEC 5 7SD82 (CP100) (All versions), SIPROTEC 5 7SD82 (CP150) (All versions), SIPROTEC 5 7SD86 (CP200) (All versions), SIPROTEC 5 7SD86 (CP300) (All versions), SIPROTEC 5 7SD87 (CP200) (All versions), SIPROTEC 5 7SD87 (CP300) (All versions), SIPROTEC 5 7SJ81 (CP100) (All versions), SIPROTEC 5 7SJ81 (CP150) (All versions), SIPROTEC 5 7SJ82 (CP100) (All versions), SIPROTEC 5 7SJ82 (CP150) (All versions), SIPROTEC 5 7SJ85 (CP200) (All versions), SIPROTEC 5 7SJ85 (CP300) (All versions), SIPROTEC 5 7SJ86 (CP200) (All versions), SIPROTEC 5 7SJ86 (CP300) (All versions), SIPROTEC 5 7SK82 (CP100) (All versions), SIPROTEC 5 7SK82 (CP150) (All versions), SIPROTEC 5 7SK85 (CP200) (All versions), SIPROTEC 5 7SK85 (CP300) (All versions), SIPROTEC 5 7SL82 (CP100) (All versions), SIPROTEC 5 7SL82 (CP150) (All versions), SIPROTEC 5 7SL86 (CP200) (All versions), SIPROTEC 5 7SL86 (CP300) (All versions), SIPROTEC 5 7SL87 (CP200) (All versions), SIPROTEC 5 7SL87 (CP300) (All versions), SIPROTEC 5 7SS85 (CP200) (All versions), SIPROTEC 5 7SS85 (CP300) (All versions), SIPROTEC 5 7ST85 (CP200) (All versions), SIPROTEC 5 7ST85 (CP300) (All versions), SIPROTEC 5 7ST86 (CP300) (All versions), SIPROTEC 5 7SX82 (CP150) (All versions), SIPROTEC 5 7SX85 (CP300) (All versions), SIPROTEC 5 7SY82 (CP150) (All versions), SIPROTEC 5 7UM85 (CP300) (All versions), SIPROTEC 5 7UT82 (CP100) (All versions), SIPROTEC 5 7UT82 (CP150) (All versions), SIPROTEC 5 7UT85 (CP200) (All versions), SIPROTEC 5 7UT85 (CP300) (All versions), SIPROTEC 5 7UT86 (CP200) (All versions), SIPROTEC 5 7UT86 (CP300) (All versions), SIPROTEC 5 7UT87 (CP200) (All versions), SIPROTEC 5 7UT87 (CP300) (All versions), SIPROTEC 5 7VE85 (CP300) (All versions), SIPROTEC 5 7VK87 (CP200) (All versions), SIPROTEC 5 7VK87 (CP300) (All versions), SIPROTEC 5 7VU85 (CP300) (All versions), SIPROTEC 5 Compact 7SX800 (CP050) (All versions). Affected devices do not encrypt certain data within the on-board flash storage on their PCB. This could allow an attacker with physical access to read the entire filesystem of the device. |
| A vulnerability in the IPS Manager, Central Manager, and Local Manager communication workflow allows an attacker to control the destination of a request by manipulating the parameter, thereby leveraging sensitive information. |
| A sensitive information disclosure vulnerability in Palo Alto Networks Prisma® Browser allows a locally authenticated non-admin user to retrieve sensitive data from Prisma Browser.
Browser self-protection should be enabled to mitigate this issue. |
| An authentication-bypass issue in the RDP component of One Identity Safeguard for Privileged Sessions (SPS) On Premise before 7.5.1 (and LTS before 7.0.5.1) allows man-in-the-middle attackers to obtain access to privileged sessions on target resources by intercepting cleartext RDP protocol information. |
| This vulnerability exists in TP-Link Tapo H200 V1 IoT Smart Hub due to storage of Wi-Fi credentials in plain text within the device firmware. An attacker with physical access could exploit this by extracting the firmware and analyzing the binary data to obtain the Wi-Fi credentials stored on the vulnerable device. |
| A local, low-privileged attacker can learn the password of the connected controller in PLC Designer V4 due to an incorrect implementation that results in the password being displayed in plain text under special conditions. |
| A vulnerability has been identified in SIMATIC RTLS Locating Manager (6GT2780-0DA00) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA30) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA30) (All versions < V3.0.1.1). Affected systems transmit client-side resources without proper cryptographic protection. This could allow an attacker to eavesdrop on and modify resources in transit. A successful exploit requires an attacker to be in the network path between the RTLS Locating Manager server and a client (MitM). |
| The web server of the Access Manager offers a functionality to download a backup of the local database stored on the device. This database contains the whole configuration. This includes encrypted MIFARE keys, card data, user PINs and much more. The PINs are even stored unencrypted. Combined with the fact that an attacker can easily get access to the backup functionality by abusing the session management issue (CVE-2025-59101), or by exploiting the weak default password (CVE-2025-59108), or by simply setting a new password without prior authentication via the SOAP API (CVE-2025-59097), it is easily possible to access the sensitive data on the device. |
| A vulnerability was found in Ruijie EG306MG 3.0(1)B11P309. It has been rated as problematic. This issue affects some unknown processing of the file /etc/strongswan.conf of the component strongSwan. The manipulation of the argument i_dont_care_about_security_and_use_aggressive_mode_psk leads to missing encryption of sensitive data. The attack may be initiated remotely. The complexity of an attack is rather high. The exploitation is known to be difficult. The vendor was contacted early about this disclosure but did not respond in any way. |
| A security issue was discovered within the legacy Ansible playbook component of Verve Asset Manager, caused by plaintext secrets incorrectly stored when a playbook is running. This component has been retired and has been optional since the 1.36 release in 2024. |
| An issue in YESCAM (com.yescom.YesCam.zwave) 1.0.2 allows a remote attacker to obtain sensitive information via the firmware update process. |
| In TARGIT Decision Suite 23.2.15007.0 before Autumn 2023, the session token is part of the URL and may be sent in a cleartext HTTP session. |
| Aikaan IoT management platform v3.25.0325-5-g2e9c59796 sends a newly generated password to users in plaintext via email and also includes the same password as a query parameter in the account activation URL (e.g., https://domain.com/activate=xyz). This practice can result in password exposure via browser history, proxy logs, referrer headers, and email caching. The vulnerability impacts user credential confidentiality during initial onboarding. |
| When using domain users as BRAIN2 users, communication with Active Directory services is unencrypted. This can lead to the interception of authentication data and compromise confidentiality. |
| Secure flag not set and SameSIte was set to Lax in the Foreseer Reporting Software (FRS). Absence of this secure flag could lead into the session cookie being transmitted over unencrypted HTTP connections. This security issue has been resolved in the latest version of FRS v1.5.100. |
| ** UNSUPPORTED WHEN ASSIGNED ** This vulnerability exists in D3D Security IP Camera D8801 due to usage of weak authentication scheme of the HTTP header protocol where authorization tag contain a Base-64 encoded username and password. A remote attacker could exploit this vulnerability by crafting a HTTP packet leading to exposure of user credentials of the targeted device. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. |
| SummaryThis advisory addresses a security vulnerability in Mautic where sensitive .env configuration files may be directly accessible via a web browser. This exposure could lead to the disclosure of sensitive information, including database credentials, API keys, and other critical system configurations.
Sensitive Information Disclosure via .env File Exposure: The .env file, which typically contains environment variables and sensitive application configurations, is directly accessible via a web browser due to missing web server configurations that restrict access to such files. This allows an unauthenticated attacker to view the contents of this file by simply navigating to its URL.
MitigationUpdate Mautic to the latest Mautic version.
By default, Mautic does not use .env files for production data.
For Apache users: Ensure your web server is configured to respect .htaccess files.
For Nginx users: As Nginx does not inherently support .htaccess files, you must manually add a configuration block to your Nginx server configuration to deny access to .env files. Add the following to your Nginx configuration for the Mautic site:
location ~ /\.env {
deny all;
}
After modifying your Nginx configuration, remember to reload or restart your Nginx service for the changes to take effect. |
| Cleartext Transmission of Sensitive Information vulnerability in Crestron Automate VX allows Sniffing Network Traffic.
The device allows Web UI and API access over non-secure network ports which exposes sensitive information such as user passwords.
This issue affects Automate VX: from 5.6.8161.21536 through 6.4.0.49. |
| A vulnerability has been identified in POWER METER SICAM Q100 (7KG9501-0AA01-0AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q100 (7KG9501-0AA01-2AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q100 (7KG9501-0AA31-0AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q100 (7KG9501-0AA31-2AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q200 family (All versions >= V2.70 < V2.80). Affected devices export the password for the SMTP account as plain text in the Configuration File. This could allow an authenticated local attacker to extract it and use the configured SMTP service for arbitrary purposes. |