Search

Search Results (357515 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2019-7747 1 Dbninja 1 Dbninja 2024-11-21 N/A
DbNinja 3.2.7 allows session fixation via the data.php sessid parameter.
CVE-2019-7746 1 Jio 2 Jmr1140, Jmr1140 Firmware 2024-11-21 N/A
JioFi 4 jmr1140 Amtel_JMR1140_R12.07 devices allow remote attackers to obtain an admin token by making a /cgi-bin/qcmap_auth type=getuser request and then reading the token field. This token value can then be used to change the Wi-Fi password or perform a factory reset.
CVE-2019-7745 1 Jio 2 Jmr1140, Jmr1140 Firmware 2024-11-21 N/A
JioFi 4 jmr1140 Amtel_JMR1140_R12.07 devices allow remote attackers to obtain the Wi-Fi password by making a cgi-bin/qcmap_web_cgi Page=GetWiFi_Setting request and then reading the wpa_security_key field.
CVE-2019-7744 1 Joomla 1 Joomla\! 2024-11-21 N/A
An issue was discovered in Joomla! before 3.9.3. Inadequate filtering on URL fields in various core components could lead to an XSS vulnerability.
CVE-2019-7743 1 Joomla 1 Joomla\! 2024-11-21 N/A
An issue was discovered in Joomla! before 3.9.3. The phar:// stream wrapper can be used for objection injection attacks because there is no protection mechanism (such as the TYPO3 PHAR stream wrapper) to prevent use of the phar:// handler for non .phar-files.
CVE-2019-7742 1 Joomla 1 Joomla\! 2024-11-21 N/A
An issue was discovered in Joomla! before 3.9.3. A combination of specific web server configurations, in connection with specific file types and browser-side MIME-type sniffing, causes an XSS attack vector.
CVE-2019-7741 1 Joomla 1 Joomla\! 2024-11-21 N/A
An issue was discovered in Joomla! before 3.9.3. Inadequate checks at the Global Configuration helpurl settings allowed stored XSS.
CVE-2019-7740 1 Joomla 1 Joomla\! 2024-11-21 N/A
An issue was discovered in Joomla! before 3.9.3. Inadequate parameter handling in JavaScript code (core.js writeDynaList) could lead to an XSS attack vector.
CVE-2019-7739 1 Joomla 1 Joomla\! 2024-11-21 N/A
An issue was discovered in Joomla! before 3.9.3. The "No Filtering" textfilter overrides child settings in the Global Configuration. This is intended behavior. However, it might be unexpected for the user because the configuration dialog lacks an additional message to explain this.
CVE-2019-7738 1 C.p.sub Project 1 C.p.sub 2024-11-21 N/A
C.P.Sub before 5.3 allows CSRF via a manage.php?p=article_del&id= URI.
CVE-2019-7737 1 Verydows 1 Verydows 2024-11-21 N/A
A CSRF vulnerability was found in Verydows v2.0 that can add an admin account via index.php?m=backend&c=admin&a=add&step=submit.
CVE-2019-7736 1 Dlink 2 Dir-600m, Dir-600m Firmware 2024-11-21 N/A
D-Link DIR-600M C1 3.04 devices allow authentication bypass via a direct request to the wan.htm page. NOTE: this may overlap CVE-2019-13101.
CVE-2019-7733 1 Live555 1 Streaming Media 2024-11-21 N/A
In Live555 0.95, there is a buffer overflow via a large integer in a Content-Length HTTP header because handleRequestBytes has an unrestricted memmove.
CVE-2019-7732 1 Live555 1 Streaming Media 2024-11-21 N/A
In Live555 0.95, a setup packet can cause a memory leak leading to DoS because, when there are multiple instances of a single field (username, realm, nonce, uri, or response), only the last instance can ever be freed.
CVE-2019-7731 1 Mywebsql 1 Mywebsql 2024-11-21 N/A
MyWebSQL 3.7 has a remote code execution (RCE) vulnerability after an attacker writes shell code into the database, and executes the Backup Database function with a .php filename for the backup's archive file.
CVE-2019-7730 1 Mywebsql 1 Mywebsql 2024-11-21 N/A
MyWebSQL 3.7 has a Cross-site request forgery (CSRF) vulnerability for deleting a database via the /?q=wrkfrm&type=databases URI.
CVE-2019-7729 1 Bosch 1 Smart Camera 2024-11-21 N/A
An issue was discovered in the Bosch Smart Camera App before 1.3.1 for Android. Due to setting of insecure permissions, a malicious app could potentially succeed in retrieving video clips or still images that have been cached for clip sharing. (The Bosch Smart Home App is not affected. iOS Apps are not affected.)
CVE-2019-7728 1 Bosch 1 Smart Camera 2024-11-21 N/A
An issue was discovered in the Bosch Smart Camera App before 1.3.1 for Android. Due to improperly implemented TLS certificate checks, a malicious actor could potentially succeed in executing a man-in-the-middle attack for some connections. (The Bosch Smart Home App is not affected. iOS Apps are not affected.)
CVE-2019-7727 1 Nice 1 Engage 2024-11-21 N/A
In NICE Engage through 6.5, the default configuration binds an unauthenticated JMX/RMI interface to all network interfaces, without restricting registration of MBeans, which allows remote attackers to execute arbitrary code via the RMI protocol by using the JMX connector. The observed affected TCP port is 6338 but, based on the product's configuration, a different one could be vulnerable.
CVE-2019-7726 1 Nukeviet 1 Nukeviet 2024-11-21 9.8 Critical
modules/banners/funcs/click.php in NukeViet before 4.3.04 has a SQL INSERT statement with raw header data from an HTTP request (e.g., Referer and User-Agent).