| A vulnerability has been identified in SIPROTEC 4 and SIPROTEC Compact relays equipped with EN100 Ethernet communication modules (All versions). Specially crafted packets sent to port 50000/UDP of the EN100 Ethernet communication modules could cause a Denial-of-Service of the affected device. A manual reboot is required to recover the service of the device. At the time of advisory publication no public exploitation of this security vulnerability was known to Siemens. |
| A vulnerability has been identified in SINAMICS PERFECT HARMONY GH180 Drives MLFB 6SR32..-.....-.... MLFB 6SR4...-.....-.... MLFB 6SR5...-.....-.... With option A30 (HMIs 12 inches or larger) (All versions), SINAMICS PERFECT HARMONY GH180 Drives MLFB 6SR325.-.....-.... (High Availability) (All versions). The affected device contains a vulnerability that could allow an unauthenticated attacker to restore the affected device to a point where predefined application and operating system protection mechanisms are not in place. Successful exploitation requires physical access to the system, but no system privileges and no user interaction. An attacker could use the vulnerability to compromise confidentialiy, integrity and availability of the device. At the time of advisory publication no public exploitation of this security vulnerability was known. |
| A vulnerability has been identified in SIPORT MP (All versions < 3.1.4). Vulnerable versions of the device allow the creation of special accounts ("service users") with administrative privileges that could enable a remote authenticated attacker to perform actions that are not visible to other users of the system, such as granting persons access to a secured area. |
| A vulnerability has been identified in SIMATIC HMI Comfort Panels 1st Generation (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels (All versions < V16 Update 4). Specially crafted packets sent to port 161/udp can cause the SNMP service of affected devices to crash. A manual restart of the device is required to resume operation of the service. |
| typed_ast 1.3.0 and 1.3.1 has an ast_for_arguments out-of-bounds read. An attacker with the ability to cause a Python interpreter to parse Python source (but not necessarily execute it) may be able to crash the interpreter process. This could be a concern, for example, in a web-based service that parses (but does not execute) Python code. (This issue also affected certain Python 3.8.0-alpha prereleases.) |
| typed_ast 1.3.0 and 1.3.1 has a handle_keywordonly_args out-of-bounds read. An attacker with the ability to cause a Python interpreter to parse Python source (but not necessarily execute it) may be able to crash the interpreter process. This could be a concern, for example, in a web-based service that parses (but does not execute) Python code. (This issue also affected certain Python 3.8.0-alpha prereleases.) |
| On Samsung mobile devices with O(8.0) and P(9.0) software and an Exynos 8895 chipset, RKP (aka the Samsung Hypervisor EL2 implementation) allows arbitrary memory write operations. The Samsung ID is SVE-2019-16265. |
| An issue was discovered in tls_verify_crl in ProFTPD before 1.3.6. Direct dereference of a NULL pointer (a variable initialized to NULL) leads to a crash when validating the certificate of a client connecting to the server in a TLS client/server mutual-authentication setup. |
| An issue was discovered in tls_verify_crl in ProFTPD before 1.3.6. A wrong iteration variable, used when checking a client certificate against CRL entries (installed by a system administrator), can cause some CRL entries to be ignored, and can allow clients whose certificates have been revoked to proceed with a connection to the server. |
| An issue was discovered in tls_verify_crl in ProFTPD through 1.3.6b. Failure to check for the appropriate field of a CRL entry (checking twice for subject, rather than once for subject and once for issuer) prevents some valid CRLs from being taken into account, and can allow clients whose certificates have been revoked to proceed with a connection to the server. |
| An issue was discovered in tls_verify_crl in ProFTPD through 1.3.6b. A dereference of a NULL pointer may occur. This pointer is returned by the OpenSSL sk_X509_REVOKED_value() function when encountering an empty CRL installed by a system administrator. The dereference occurs when validating the certificate of a client connecting to the server in a TLS client/server mutual-authentication setup. |
| IceWarp WebMail Server 12.2.0 and 12.1.x before 12.2.1.1 (and probably earlier versions) allows XSS (issue 2 of 2) in notes for objects. |
| IceWarp WebMail Server 12.2.0 and 12.1.x before 12.2.1.1 (and probably earlier versions) allows XSS (issue 1 of 2) in notes for contacts. |
| In Simplifile RecordFusion through 2019-11-25, the logs and hist parameters allow remote attackers to access local files via a logger/logs?/../ or logger/hist?/../ URI. |
| GitLab Enterprise Edition (EE) 8.2 and later through 12.5 has Insecure Permissions. |
| GitLab Enterprise Edition (EE) 11.9 and later through 12.5 has Insecure Permissions. |
| GitLab Enterprise Edition (EE) 6.7 and later through 12.5 allows SSRF. |
| GitLab Community Edition (CE) and Enterprise Edition (EE) through 12.5 has Incorrect Access Control (issue 2 of 2). |
| GitLab Enterprise Edition (EE) 11.3 and later through 12.5 allows an Insecure Direct Object Reference (IDOR). |
| GitLab Enterprise Edition (EE) 10.8 and later through 12.5 has Incorrect Access Control. |