CVE-2019-13931 1 Siemens 1 Xhq 2024-11-21 5.4 Medium
A vulnerability has been identified in XHQ (All versions < V6.0.0.2). The web interface could allow for an an attacker to craft the input in a form that is not expected, causing the application to behave in unexpected ways for legitimate users. Successful exploitation requires for an attacker to be authenticated to the web interface. A successful attack could cause the application to have unexpected behavior. This could allow the attacker to modify contents of the web application. At the time of advisory publication no public exploitation of this security vulnerability was known.
CVE-2019-13930 1 Siemens 1 Xhq 2024-11-21 8.1 High
A vulnerability has been identified in XHQ (All versions < V6.0.0.2). The web interface could allow a Cross-Site Request Forgery (CSRF) attack if an unsuspecting user is tricked into accessing a malicious link. Successful exploitation requires user interaction by a legitimate user, who must be authenticated to the web interface. A successful attack could allow an attacker to trigger actions via the web interface that the legitimate user is allowed to perform. This could allow the attacker to read or modify contents of the web application. At the time of advisory publication no public exploitation of this security vulnerability was known.
CVE-2019-13929 1 Siemens 1 Simatic It Uadm 2024-11-21 6.5 Medium
A vulnerability has been identified in SIMATIC IT UADM (All versions < V1.3). An authenticated remote attacker with network access to port 1434/tcp of SIMATIC IT UADM could potentially recover a password that can be used to gain read and write access to the related TeamCenter station. The security vulnerability could be exploited only if the attacker is authenticated. No user interaction is required to exploit this security vulnerability. Successful exploitation of the security vulnerability compromises the confidentiality of the targeted system. At the time of advisory publication no public exploitation of this security vulnerability was known.
CVE-2019-13927 1 Siemens 32 Pxa30-w0, Pxa30-w0 Firmware, Pxa30-w1 and 29 more 2024-11-21 5.3 Medium
A vulnerability has been identified in Desigo PX automation controllers PXC00-E.D, PXC50-E.D, PXC100-E.D, PXC200-E.D with Desigo PX Web modules PXA40-W0, PXA40-W1, PXA40-W2 (All firmware versions < V6.00.320), Desigo PX automation controllers PXC00-U, PXC64-U, PXC128-U with Desigo PX Web modules PXA30-W0, PXA30-W1, PXA30-W2 (All firmware versions < V6.00.320), Desigo PX automation controllers PXC22.1-E.D, PXC36-E.D, PXC36.1-E.D with activated web server (All firmware versions < V6.00.320). The device contains a vulnerability that could allow an attacker to cause a denial of service condition on the device's web server by sending a specially crafted HTTP message to the web server port (tcp/80). The security vulnerability could be exploited by an attacker with network access to an affected device. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise the availability of the device's web service. While the device itself stays operational, the web server responds with HTTP status code 404 (Not found) to any further request. A reboot is required to recover the web interface. At the time of advisory publication no public exploitation of this security vulnerability was known.
CVE-2019-13926 1 Siemens 8 Scalance S602, Scalance S602 Firmware, Scalance S612 and 5 more 2024-11-21 7.5 High
A vulnerability has been identified in SCALANCE S602 (All versions >= V3.0 and < V4.1), SCALANCE S612 (All versions >= V3.0 and < V4.1), SCALANCE S623 (All versions >= V3.0 and < V4.1), SCALANCE S627-2M (All versions >= V3.0 and < V4.1). Specially crafted packets sent to port 443/tcp of affected devices could cause a Denial-of-Service condition of the web server. A cold reboot is required to restore the functionality of the device.
CVE-2019-13925 1 Siemens 8 Scalance S602, Scalance S602 Firmware, Scalance S612 and 5 more 2024-11-21 7.5 High
A vulnerability has been identified in SCALANCE S602 (All versions >= V3.0 and < V4.1), SCALANCE S612 (All versions >= V3.0 and < V4.1), SCALANCE S623 (All versions >= V3.0 and < V4.1), SCALANCE S627-2M (All versions >= V3.0 and < V4.1). Specially crafted packets sent to port 443/tcp of affected devices could cause a Denial-of-Service condition of the web server.
CVE-2019-13924 1 Siemens 16 Scalance X-200irt, Scalance X-200irt Firmware, Scalance X-300 and 13 more 2024-11-21 5.4 Medium
A vulnerability has been identified in SCALANCE S602 (All versions < V4.1), SCALANCE S612 (All versions < V4.1), SCALANCE S623 (All versions < V4.1), SCALANCE S627-2M (All versions < V4.1), SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < 5.2.4), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0), SCALANCE X-200RNA switch family (All versions < V3.2.7), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions < 4.1.3). The device does not send the X-Frame-Option Header in the administrative web interface, which makes it vulnerable to Clickjacking attacks. The security vulnerability could be exploited by an attacker that is able to trick an administrative user with a valid session on the target device into clicking on a website controlled by the attacker. The vulnerability could allow an attacker to perform administrative actions via the web interface.
CVE-2019-13923 1 Siemens 2 Ie\/wsn-pa Link Wirelesshart Gateway, Ie\/wsn-pa Link Wirelesshart Gateway Firmware 2024-11-21 9.6 Critical
A vulnerability has been identified in IE/WSN-PA Link WirelessHART Gateway (All versions). The integrated configuration web server of the affected device could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into accessing a malicious link. User interaction is required for a successful exploitation. The user must be logged into the web interface in order for the exploitation to succeed. At the stage of publishing this security advisory no public exploitation is known.
CVE-2019-13922 1 Siemens 1 Sinema Remote Connect Server 2024-11-21 2.7 Low
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V2.0 SP1). An attacker with administrative privileges can obtain the hash of a connected device's password. The security vulnerability could be exploited by an attacker with network access to the SINEMA Remote Connect Server and administrative privileges. At the time of advisory publication no public exploitation of this security vulnerability was known.
CVE-2019-13921 1 Siemens 1 Simatic Winac Rtx \(f\) 2010 2024-11-21 7.5 High
A vulnerability has been identified in SIMATIC WinAC RTX (F) 2010 (All versions < SP3 Update 1). Affected versions of the software contain a vulnerability that could allow an unauthenticated attacker to trigger a denial-of-service condition. The vulnerability can be triggered if a large HTTP request is sent to the executing service. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the service provided by the software.
CVE-2019-13920 1 Siemens 1 Sinema Remote Connect Server 2024-11-21 4.3 Medium
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V2.0 SP1). Some parts of the web application are not protected against Cross Site Request Forgery (CSRF) attacks. The security vulnerability could be exploited by an attacker that is able to trigger requests of a logged-in user to the application. The vulnerability could allow switching the connectivity state of a user or a device. At the time of advisory publication no public exploitation of this security vulnerability was known.
CVE-2019-13919 1 Siemens 1 Sinema Remote Connect Server 2024-11-21 4.3 Medium
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V2.0 SP1). Some pages that should only be accessible by a privileged user can also be accessed by a non-privileged user. The security vulnerability could be exploited by an attacker with network access and valid credentials for the web interface. No user interaction is required. The vulnerability could allow an attacker to access information that he should not be able to read. The affected information does not include passwords. At the time of advisory publication no public exploitation of this security vulnerability was known.
CVE-2019-13918 1 Siemens 1 Sinema Remote Connect Server 2024-11-21 9.8 Critical
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V2.0 SP1). The web interface has no means to prevent password guessing attacks. The vulnerability could be exploited by an attacker with network access to the vulnerable software, requiring no privileges and no user interaction. The vulnerability could allow full access to the web interface. At the time of advisory publication no public exploitation of this security vulnerability was known.
CVE-2019-13917 2 Debian, Exim 2 Debian Linux, Exim 2024-11-21 N/A
Exim 4.85 through 4.92 (fixed in 4.92.1) allows remote code execution as root in some unusual configurations that use the ${sort } expansion for items that can be controlled by an attacker (e.g., $local_part or $domain).
CVE-2019-13916 1 Cypress 3 Cyw20735b1, Cyw20819a1, Wiced Studio 2024-11-21 8.8 High
An issue was discovered in Cypress (formerly Broadcom) WICED Studio 6.2 CYW20735B1 and CYW20819A1. As a Bluetooth Low Energy (BLE) packet is received, it is copied into a Heap (ThreadX Block) buffer. The buffer allocated in dhmulp_getRxBuffer is four bytes too small to hold the maximum of 255 bytes plus headers. It is possible to corrupt a pointer in the linked list holding the free buffers of the g_mm_BLEDeviceToHostPool Block pool. This pointer can be fully controlled by overflowing with 3 bytes of packet data and the first byte of the packet CRC checksum. The checksum can be freely chosen by adapting the packet data accordingly. An attacker might be able to allocate the overwritten address as a receive buffer resulting in a write-what-where condition. This is fixed in BT SDK2.4 and BT SDK2.45.
CVE-2019-13915 1 B3log 1 Wide 2024-11-21 N/A
b3log Wide before 1.6.0 allows three types of attacks to access arbitrary files. First, the attacker can write code in the editor, and compile and run it approximately three times to read an arbitrary file. Second, the attacker can create a symlink, and then place the symlink into a ZIP archive. An unzip operation leads to read access, and write access (depending on file permissions), to the symlink target. Third, the attacker can import a Git repository that contains a symlink, similarly leading to read and write access.
CVE-2019-13768 1 Google 1 Chrome 2024-11-21 7.4 High
Use after free in FileAPI in Google Chrome prior to 72.0.3626.81 allowed a remote attacker to potentially perform a sandbox escape via a crafted HTML page. (Chrome security severity: High)
CVE-2019-13767 5 Debian, Fedoraproject, Google and 2 more 5 Debian Linux, Fedora, Chrome and 2 more 2024-11-21 8.8 High
Use after free in media picker in Google Chrome prior to 79.0.3945.88 allowed a remote attacker who had compromised the renderer process to potentially exploit heap corruption via a crafted HTML page.
CVE-2019-13766 1 Google 1 Chrome 2024-11-21 6.5 Medium
Use-after-free in accessibility in Google Chrome prior to 77.0.3865.75 allowed a remote attacker to potentially exploit heap corruption via a crafted HTML page.
CVE-2019-13765 1 Google 1 Chrome 2024-11-21 6.5 Medium
Use-after-free in content delivery manager in Google Chrome prior to 78.0.3904.70 allowed a remote attacker to potentially exploit heap corruption via a crafted HTML page.