| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Rapid7 Velociraptor MSI Installer versions below 0.73.3 suffer from a vulnerability whereby it creates the installation directory with WRITE_DACL permission to the BUILTIN\\Users group. This allows local users who are not administrators to grant themselves the Full Control permission on Velociraptor's files. By modifying Velociraptor's files, local users can subvert the binary and cause the Velociraptor service to execute arbitrary code as the SYSTEM user, or to replace the Velociraptor binary completely. This issue is fixed in version 0.73.3. |
| The CGI script <redacted>.sh can be used to download any file on the filesystem.
This issue affects Iocharger firmware for AC model chargers beforeversion 24120701.
Likelihood: High, but credentials required.
Impact: Critical – The script can be used to download any file on the filesystem, including sensitive files such as /etc/shadow, the CGI script source code or binaries and configuration files.
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/S:P/AU:Y
CVSS clarification. The attack can be executed over any network connection the station is listening to and serves the web interface (AV:N), and there are no additional security measure sin place that need to be circumvented (AC:L), the attack does not rely on preconditions (AT:N). The attack does require authentication, but the level of authentication is irrelevant (PR:L), it does not require user interaction (UI:N). The confidentiality of all files of the devicd can be compromised (VC:H/VI:N/VA:N). There is no impact on subsequent systems. (SC:N/SI:N/SA:N). While this device is an EV charger handing significant amounts of power, this attack in isolation does not have a safety impact. The attack can be automated (AU:Y). |
| A security vulnerability in HPE IceWall products could be exploited remotely to cause Unauthorized Data Modification. |
| A vulnerability, which was classified as problematic, has been found in SunGrow Logger1000 01_A. This issue affects some unknown processing. The manipulation leads to weak password requirements. The attack may be initiated remotely. The complexity of an attack is rather high. The exploitation is known to be difficult. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. |
| The matrix-sdk-crypto crate, part of the Matrix Rust SDK project, is an implementation of a Matrix end-to-end encryption state machine in Rust. In Matrix, the server-side `key backup` stores encrypted copies of Matrix message keys. This facilitates key sharing between a user's devices and provides a redundant copy in case all devices are lost. The key backup uses asymmetric
cryptography, with each server-side key backup assigned a unique public-private key pair. Due to a logic bug introduced in commit 71136e44c03c79f80d6d1a2446673bc4d53a2067, matrix-sdk-crypto version 0.7.0 will sometimes log the private part of the backup key pair to Rust debug logs (using the `tracing` crate). This issue has been resolved in matrix-sdk-crypto version 0.7.1. No known workarounds are available. |
| OpenBD 20210306203917-6cbe797 is vulnerable to Deserialization of Untrusted Data. The cookies bdglobals and bdclient_spot of the OpenBD software uses serialized data, which can be used to execute arbitrary code on the system. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. |
| A vulnerability has been identified in SIMATIC S7-PLCSIM V17 (All versions), SIMATIC STEP 7 V17 (All versions < V17 Update 9), SIMATIC STEP 7 V18 (All versions), SIMATIC STEP 7 V19 (All versions < V19 Update 4), SIMATIC STEP 7 V20 (All versions < V20 Update 4), SIMATIC WinCC V17 (All versions < V17 Update 9), SIMATIC WinCC V18 (All versions), SIMATIC WinCC V19 (All versions < V19 Update 4), SIMATIC WinCC V20 (All versions < V20 Update 4), SIMOCODE ES V17 (All versions), SIMOCODE ES V18 (All versions), SIMOCODE ES V19 (All versions), SIMOCODE ES V20 (All versions), SIMOTION SCOUT TIA V5.4 (All versions), SIMOTION SCOUT TIA V5.5 (All versions), SIMOTION SCOUT TIA V5.6 (All versions < V5.6 SP1 HF7), SIMOTION SCOUT TIA V5.7 (All versions), SINAMICS Startdrive V17 (All versions), SINAMICS Startdrive V18 (All versions), SINAMICS Startdrive V19 (All versions), SINAMICS Startdrive V20 (All versions), SIRIUS Safety ES V17 (TIA Portal) (All versions), SIRIUS Safety ES V18 (TIA Portal) (All versions), SIRIUS Safety ES V19 (TIA Portal) (All versions), SIRIUS Safety ES V20 (TIA Portal) (All versions), SIRIUS Soft Starter ES V17 (TIA Portal) (All versions), SIRIUS Soft Starter ES V18 (TIA Portal) (All versions), SIRIUS Soft Starter ES V19 (TIA Portal) (All versions), SIRIUS Soft Starter ES V20 (TIA Portal) (All versions), TIA Portal Cloud V17 (All versions), TIA Portal Cloud V18 (All versions), TIA Portal Cloud V19 (All versions < V5.2.1.1), TIA Portal Cloud V20 (All versions < V5.2.2.2). Affected products do not properly sanitize stored security properties when parsing project files. This could allow an attacker to cause a type confusion and execute arbitrary code within the affected application. |
| A vulnerability was found in QKSMS up to 3.9.4 on Android. It has been classified as problematic. This affects an unknown part of the file androidmanifest.xml of the component Backup File Handler. The manipulation leads to exposure of backup file to an unauthorized control sphere. It is possible to launch the attack on the physical device. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-259611. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. |
| MTPutty 1.0.1.21 contains a sensitive information disclosure vulnerability that allows local attackers to view SSH connection passwords through Windows PowerShell process listing. Attackers can run a PowerShell command to retrieve the full command line of MTPutty processes, exposing plaintext SSH credentials. |
| Insecure deserialization in Hodoku v2.3.0 to v2.3.2 allows attackers to execute arbitrary code. |
| The WP Database Backup – Unlimited Database & Files Backup by Backup for WP plugin for WordPress is vulnerable to Sensitive Information Exposure in all versions up to, and including, 7.3 via publicly accessible back-up files. This makes it possible for unauthenticated attackers to extract sensitive data including all information stored in the database. |
| Deserialization of Untrusted Data vulnerability in WebToffee Order Export & Order Import for WooCommerce.This issue affects Order Export & Order Import for WooCommerce: from n/a through 2.4.9. |
| Dependency-Track is a component analysis platform that allows organizations to identify and reduce risk in the software supply chain. Prior to version 4.13.5, Dependency-Track may send credentials meant for a private NuGet repository to `api.nuget.org` via the HTTP `Authorization` header, and may disclose names and versions of components marked as internal to `api.nuget.org`. This can happen if the Dependency-Track instance contains .NET components, a custom NuGet repository has been configured, the custom repository has been configured with authentication credentials, and the repository server does not provide `PackageBaseAddress` resource in its service index. The issue has been fixed in Dependency-Track 4.13.5. Some workarounds are avaialble. Disable custom NuGet repositories until the patch has been applied, invalidate the previously used credentials, and generate new credentials for usage after the patch has been applied. |
| NVIDIA RAPIDS contains a vulnerability in cuDF and cuML, where a user could cause a deserialization of untrusted data issue. A successful exploit of this vulnerability might lead to code execution, data tampering, denial of service, and information disclosure. |
| A vulnerability has been identified in Rancher Manager, where sensitive
information, including secret data, cluster import URLs, and
registration tokens, is exposed to any entity with access to Rancher
audit logs. |
| Weak Password Requirements vulnerability in Mitsubishi Electric Corporation photovoltaic system monitor “EcoGuideTAB” PV-DR004J all versions and PV-DR004JA all versions allows an attacker within the Wi-Fi communication range between the units of the product (measurement unit and display unit) to derive the password from the SSID. In addition, if the product is configured to enable the individual air conditioner control function, an attacker who has access to the Wi-Fi communication between the units by exploiting this vulnerability may be able to execute ECHONET Lite commands to perform operations such as turning the air conditioner on or off and changing the set temperature. The individual air conditioner control function is available only in display unit version 02.00.01 or later and measurement unit version 02.03.01 or later. The affected products discontinued in 2015, support ended in 2020. |
| A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions < V9.80), SIPROTEC 5 6MD85 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 6MD86 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 6MD89 (CP300) (All versions >= V7.80 < V9.68), SIPROTEC 5 6MU85 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7KE85 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7SA82 (CP100) (All versions >= V7.80 < V8.90), SIPROTEC 5 7SA82 (CP150) (All versions < V9.80), SIPROTEC 5 7SA86 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7SA87 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7SD82 (CP100) (All versions >= V7.80 < V8.90), SIPROTEC 5 7SD82 (CP150) (All versions < V9.80), SIPROTEC 5 7SD86 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7SD87 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7SJ81 (CP100) (All versions >= V7.80 < V8.90), SIPROTEC 5 7SJ81 (CP150) (All versions < V9.80), SIPROTEC 5 7SJ82 (CP100) (All versions >= V7.80 < V8.90), SIPROTEC 5 7SJ82 (CP150) (All versions < V9.80), SIPROTEC 5 7SJ85 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7SJ86 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7SK82 (CP100) (All versions >= V7.80 < V8.90), SIPROTEC 5 7SK82 (CP150) (All versions < V9.80), SIPROTEC 5 7SK85 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7SL82 (CP100) (All versions >= V7.80 < V8.90), SIPROTEC 5 7SL82 (CP150) (All versions < V9.80), SIPROTEC 5 7SL86 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7SL87 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7SS85 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7ST85 (CP300) (All versions < V9.68), SIPROTEC 5 7ST86 (CP300) (All versions < V9.80), SIPROTEC 5 7SX82 (CP150) (All versions < V9.80), SIPROTEC 5 7SX85 (CP300) (All versions < V9.80), SIPROTEC 5 7SY82 (CP150) (All versions < V9.80), SIPROTEC 5 7UM85 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7UT82 (CP100) (All versions >= V7.80 < V8.90), SIPROTEC 5 7UT82 (CP150) (All versions < V9.80), SIPROTEC 5 7UT85 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7UT86 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7UT87 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7VE85 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7VK87 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7VU85 (CP300) (All versions < V9.80), SIPROTEC 5 Compact 7SX800 (CP050) (All versions < V9.80). Affected devices do not properly limit the path accessible via their webserver. This could allow an authenticated remote attacker to read arbitrary files from the filesystem of affected devices. |
| Improper restriction of environment variables in Elastic Defend can lead to exposure of sensitive information such as API keys and tokens via automatic transmission of unfiltered environment variables to the stack. |
| A vulnerability has been identified in SINUMERIK 828D V4 (All versions < V4.95 SP3), SINUMERIK 840D sl V4 (All versions < V4.95 SP3 in connection with using Create MyConfig (CMC) <= V4.8 SP1 HF6), SINUMERIK ONE (All versions < V6.23 in connection with using Create MyConfig (CMC) <= V6.6), SINUMERIK ONE (All versions < V6.15 SP4 in connection with using Create MyConfig (CMC) <= V6.6). Affected systems, that have been provisioned with Create MyConfig (CMC), contain a Insertion of Sensitive Information into Log File vulnerability. This could allow a local authenticated user with low privileges to read sensitive information and thus circumvent access restrictions. |
| Deserialization of Untrusted Data vulnerability in BoldGrid Client Invoicing by Sprout Invoices sprout-invoices allows Object Injection.This issue affects Client Invoicing by Sprout Invoices: from n/a through <= 20.8.7. |