| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| The checkPassword function in python-kerberos does not authenticate the KDC it attempts to communicate with, which allows remote attackers to cause a denial of service (bad response), or have other unspecified impact by performing a man-in-the-middle attack. |
| An issue was discovered in Veritas NetBackup 8.0 and earlier and NetBackup Appliance 3.0 and earlier. Unauthenticated CORBA interfaces permit inappropriate access. |
| The 'Find Phone' function in Nice smartphones with software versions earlier before Nice-AL00C00B0135 has an authentication bypass vulnerability. An unauthenticated attacker may wipe and factory reset the phone by special steps. Due to missing authentication of the 'Find Phone' function, an attacker may exploit the vulnerability to bypass the 'Find Phone' function in order to use the phone normally. |
| Exploitation of Authentication vulnerability in the web interface in McAfee Advanced Threat Defense (ATD) 3.10, 3.8, 3.6, 3.4 allows remote unauthenticated users / remote attackers to bypass ATD detection via loose enforcement of authentication and authorization. |
| Weak access control methods on the TP-Link TL-SG108E 1.0.0 allow any user on a NAT network with an authenticated administrator to access the device without entering user credentials. The authentication record is stored on the device; thus if an administrator authenticates from a NAT network, the authentication applies to the IP address of the NAT gateway, and any user behind that NAT gateway is also treated as authenticated. |
| phpMyFAQ before 2.9.8 does not properly mitigate brute-force attacks that try many passwords in attempted logins quickly. |
| An issue was discovered on Humax Digital HG100R 2.0.6 devices. To download the backup file it's not necessary to use credentials, and the router credentials are stored in plaintext inside the backup, aka GatewaySettings.bin. |
| register_send.php on D-Link DIR-850L REV. B (with firmware through FW208WWb02) devices does not require authentication, which can result in unintended enrollment in mydlink Cloud Services. |
| ACTi cameras including the D, B, I, and E series using firmware version A1D-500-V6.11.31-AC fail to properly restrict access to the factory reset page. An unauthenticated, remote attacker can exploit this vulnerability by directly accessing the http://x.x.x.x/setup/setup_maintain_firmware-default.html page. This will allow an attacker to perform a factory reset on the device, leading to a denial of service condition or the ability to make use of default credentials (CVE-2017-3186). |
| A vulnerability was discovered in Siemens SiPass integrated (All versions before V2.70) that could allow an attacker in a Man-in-the-Middle position between the SiPass integrated server and SiPass integrated clients to read or modify the network communication. |
| Trustwave Secure Web Gateway (SWG) through 11.8.0.27 allows remote attackers to append an arbitrary public key to the device's SSH Authorized Keys data, and consequently obtain remote root access, via the publicKey parameter to the /sendKey URI. |
| WiMAX routers based on the MediaTek SDK (libmtk) that use a custom httpd plugin are vulnerable to an authentication bypass allowing a remote, unauthenticated attacker to gain administrator access to the device by performing an administrator password change on the device via a crafted POST request. |
| Nextcloud Server before 9.0.54 and 10.0.1 & ownCloud Server before 9.1.2, 9.0.6, and 8.2.9 suffer from SMB User Authentication Bypass. Nextcloud/ownCloud include an optional and not by default enabled SMB authentication component that allows authenticating users against an SMB server. This backend is implemented in a way that tries to connect to a SMB server and if that succeeded consider the user logged-in. The backend did not properly take into account SMB servers that have any kind of anonymous auth configured. This is the default on SMB servers nowadays and allows an unauthenticated attacker to gain access to an account without valid credentials. Note: The SMB backend is disabled by default and requires manual configuration in the Nextcloud/ownCloud config file. If you have not configured the SMB backend then you're not affected by this vulnerability. |
| Remote enabling and disabling admin interface in Gemalto's HASP SRM, Sentinel HASP and Sentinel LDK products prior to Sentinel LDK RTE version 7.55 leads to new attack vectors. |
| A potential security vulnerability has been identified in HPE Application Performance Management (BSM) Platform versions 9.26, 9.30, 9.40. The vulnerability could be remotely exploited to allow code execution. |
| A privilege escalation vulnerability in the Secure Shell (SSH) subsystem in the StarOS operating system for Cisco ASR 5000 Series, ASR 5500 Series, ASR 5700 Series devices, and Cisco Virtualized Packet Core could allow an authenticated, remote attacker to gain unrestricted, root shell access. The vulnerability is due to missing input validation of parameters passed during SSH or SFTP login. An attacker could exploit this vulnerability by providing crafted user input to the SSH or SFTP command-line interface (CLI) during SSH or SFTP login. An exploit could allow an authenticated attacker to gain root privileges access on the router. Note: Only traffic directed to the affected system can be used to exploit this vulnerability. This vulnerability can be triggered via both IPv4 and IPv6 traffic. An established TCP connection toward port 22, the SSH default port, is needed to perform the attack. The attacker must have valid credentials to login to the system via SSH or SFTP. The following products have been confirmed to be vulnerable: Cisco ASR 5000/5500/5700 Series devices running StarOS after 17.7.0 and prior to 18.7.4, 19.5, and 20.2.3 with SSH configured are vulnerable. Cisco Virtualized Packet Core - Single Instance (VPC-SI) and Distributed Instance (VPC-DI) devices running StarOS prior to N4.2.7 (19.3.v7) and N4.7 (20.2.v0) with SSH configured are vulnerable. Cisco Bug IDs: CSCva65853. |
| An issue was discovered in BINOM3 Universal Multifunctional Electric Power Quality Meter. Lack of authentication for remote service gives access to application set up and configuration. |
| The Erlang otp TLS server answers with different TLS alerts to different error types in the RSA PKCS #1 1.5 padding. This allows an attacker to decrypt content or sign messages with the server's private key (this is a variation of the Bleichenbacher attack). |
| An issue was discovered in Smiths-Medical CADD-Solis Medication Safety Software, Version 1.0; 2.0; 3.0; and 3.1. CADD-Solis Medication Safety Software grants an authenticated user elevated privileges on the SQL database, which would allow an authenticated user to modify drug libraries, add and delete users, and change user permissions. According to Smiths-Medical, physical access to the pump is required to install drug library updates. |
| An improper restriction of excessive authentication attempts vulnerability in /principals in Synology CardDAV Server before 6.0.7-0085 allows remote attackers to obtain user credentials via a brute-force attack. |