| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| In ZKT ZKBio CVSecurity 6.4.1_R an unauthenticated attacker can craft JWT token using the hardcoded secret to authenticate to the service console. NOTE: the Supplier disputes the significance of this report because the service console is typically only accessible from a local area network, and because access to the service console does not result in login access or data access in the context of the application software platform. |
|
Dell EMC SCG Policy Manager, versions from 5.10 to 5.12, contain(s) a contain a Hard-coded Cryptographic Key vulnerability. An attacker with the knowledge of the hard-coded sensitive information, could potentially exploit this vulnerability to login to the system to gain admin privileges.
|
|
Dell EMC SCG Policy Manager, versions from 5.10 to 5.12, contain(s) a Hard-coded Password Vulnerability. An attacker, with the knowledge of the hard-coded credentials, could potentially exploit this vulnerability to login to the system to gain admin privileges.
|
|
Dell EMC SCG Policy Manager, versions from 5.10 to 5.12, contain(s) a contain a Hard-coded Cryptographic Key vulnerability. An attacker with the knowledge of the hard-coded sensitive information, could potentially exploit this vulnerability to login to the system to gain LDAP user privileges.
|
| Dell EMC SCG Policy Manager, versions from 5.10 to 5.12, contain(s) a contain a Hard-coded Cryptographic Key vulnerability. An attacker with the knowledge of the hard-coded sensitive information, could potentially exploit this vulnerability to login to the system to gain admin privileges.
|
| Use of hard-coded TLS certificate by default allows an attacker to perform Man-in-the-Middle (MitM) attacks even in the presence of the HTTPS connection. This issue affects: Lanner Inc IAC-AST2500A standard firmware version 1.00.0. |
| An issue was discovered in AudioCodes One Voice Operations Center (OVOC) before 8.4.582. Due to the use of a hard-coded key, an attacker is able to decrypt sensitive data such as passwords extracted from the topology file. |
| IceCMS v3.4.7 and before was discovered to contain a hardcoded JWT key, allowing an attacker to forge JWT authentication information. |
| Use of Hard-coded Cryptographic Key vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A and later allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthenticated attackers may view programs and project files or execute programs illegally. |
| Use of Hard-coded Cryptographic Key vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A and later allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthenticated attackers may view programs and project file or execute programs illegally. |
| Rundeck is an open source automation service with a web console, command line tools and a WebAPI. Rundeck community and rundeck-enterprise docker images contained a pre-generated SSH keypair. If the id_rsa.pub public key of the keypair was copied to authorized_keys files on remote host, those hosts would allow access to anyone with the exposed private credentials. This misconfiguration only impacts Rundeck Docker instances of PagerDuty® Process Automation On Prem (formerly Rundeck) version 4.0 and earlier, not Debian, RPM or .WAR. Additionally, the id_rsa.pub file would have to be copied from the Docker image filesystem contents without overwriting it and used to configure SSH access on a host. A patch on Rundeck's `main` branch has removed the pre-generated SSH key pair, but it does not remove exposed keys that have been configured. To patch, users must run a script on hosts in their environment to search for exposed keys and rotate them. Two workarounds are available: Do not use any pre-existing public key file from the rundeck docker images to allow SSH access by adding it to authorized_keys files and, if you have copied the public key file included in the docker image, remove it from any authorized_keys files. |
| Databasir is a team-oriented relational database model document management platform. Databasir 1.01 has Use of Hard-coded Cryptographic Key vulnerability. An attacker can use hard coding to generate login credentials of any user and log in to the service background located at different IP addresses. |
| A Use of Hard-Coded Cryptographic Key issue was discovered in Mirion Technologies DMC 3000 Transmitter Module, iPam Transmitter f/DMC 2000, RDS-31 iTX and variants (including RSD31-AM Package), DRM-1/2 and variants (including Solar PWR Package), DRM and RDS Based Boundary Monitors, External Transmitters, Telepole II, and MESH Repeater (Telemetry Enabled Devices). An unchangeable, factory-set key is included in the 900 MHz transmitter firmware. |
| A Use of Hard-coded Cryptographic Key issue was discovered in Korenix JetNet JetNet5018G version 1.4, JetNet5310G version 1.4a, JetNet5428G-2G-2FX version 1.4, JetNet5628G-R version 1.4, JetNet5628G version 1.4, JetNet5728G-24P version 1.4, JetNet5828G version 1.1d, JetNet6710G-HVDC version 1.1e, and JetNet6710G version 1.1. An attacker may gain access to hard-coded certificates and private keys allowing the attacker to perform man-in-the-middle attacks. |
| Ovarro TBox TWinSoft uses the custom hardcoded user “TWinSoft” with a hardcoded key. |
| The affected product has a hardcoded private key available inside the project folder, which may allow an attacker to achieve Web Server login and perform further actions. |
| Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x includes the functionality of setting a password that is required to execute privileged commands. The password value passed to ISaGRAF Runtime is the result of encryption performed with a fixed key value using the tiny encryption algorithm (TEA) on an entered or saved password. A remote, unauthenticated attacker could pass their own encrypted password to the ISaGRAF 5 Runtime, which may result in information disclosure on the device. |
| By having access to the hard-coded cryptographic key for GE Reason RT430, RT431 & RT434 GNSS clocks in firmware versions prior to version 08A06, attackers would be able to intercept and decrypt encrypted traffic through an HTTPS connection. |
| Horner Automation’s RCC 972 with firmware version 15.40 has a static encryption key on the device. This could allow an attacker to perform unauthorized changes to the device, remotely execute arbitrary code, or cause a denial-of-service condition. |
| Delta Industrial Automation DIALink versions 1.4.0.0 and prior are vulnerable to the use of a hard-coded cryptographic key which could allow an attacker to decrypt sensitive data and compromise the machine.
|