| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| The built-in WEB server for MOXA NPort IAW5000A-I/O firmware version 2.1 or lower has incorrectly implemented protections from session fixation, which may allow an attacker to gain access to a session and hijack it by stealing the user’s cookies. |
| The built-in WEB server for MOXA NPort IAW5000A-I/O firmware version 2.1 or lower allows SSH/Telnet sessions, which may be vulnerable to brute force attacks to bypass authentication. |
| The length of the input fields of Host Engineering H0-ECOM100, H2-ECOM100, and H4-ECOM100 modules are verified only on the client side when receiving input from the configuration web server, which may allow an attacker to bypass the check and send input to crash the device. |
| The built-in WEB server for MOXA NPort IAW5000A-I/O firmware version 2.1 or lower has improper privilege management, which may allow an attacker with user privileges to perform requests with administrative privileges. |
| The built-in WEB server for MOXA NPort IAW5000A-I/O firmware version 2.1 or lower allows sensitive information to be displayed without proper authorization. |
| Incorrect permissions are set by default for an API entry-point of a specific service, allowing a non-authenticated user to trigger a function that could reboot the CompactRIO (Driver versions prior to 20.5) remotely. |
| The built-in WEB server for MOXA NPort IAW5000A-I/O firmware version 2.1 or lower stores and transmits the credentials of third-party services in cleartext. |
| The affected product is vulnerable to three stack-based buffer overflows, which may allow an unauthenticated attacker to remotely execute arbitrary code on the IP150 (firmware versions 5.02.09). |
| An attacker who convinces a valid user to open a specially crafted project file to exploit could execute code under the privileges of the application due to an out-of-bounds read vulnerability on the LAquis SCADA (Versions prior to 4.3.1.870). |
| An XXE vulnerability exists within LeviStudioU Release Build 2019-09-21 and prior when processing parameter entities, which may allow file disclosure. |
| The affected product is vulnerable to five post-authentication buffer overflows, which may allow a logged in user to remotely execute arbitrary code on the IP150 (firmware versions 5.02.09). |
| WECON PLC Editor Versions 1.3.8 and prior has a heap-based buffer overflow vulnerabilities have been identified that may allow arbitrary code execution. |
| GE Healthcare Imaging and Ultrasound Products may allow specific credentials to be exposed during transport over the network. |
| WECON PLC Editor Versions 1.3.8 and prior has a stack-based buffer overflow vulnerability has been identified that may allow arbitrary code execution. |
| GE Healthcare Imaging and Ultrasound Products may allow specific credentials to be exposed during transport over the network. |
| A DLL hijacking vulnerability in the B. Braun OnlineSuite Version AP 3.0 and earlier allows local attackers to execute code on the system as a high privileged user. |
| An attacker with local network access can obtain a fixed cryptography key which may allow for further compromise of Reolink P2P cameras outside of local network access |
| A relative path traversal attack in the B. Braun OnlineSuite Version AP 3.0 and earlier allows unauthenticated attackers to upload or download arbitrary files. |
| The affected Fuji Electric V-Server Lite versions prior to 3.3.24.0 are vulnerable to an out-of-bounds write, which may allow an attacker to remotely execute arbitrary code. |
| An Excel Macro Injection vulnerability exists in the export feature in the B. Braun OnlineSuite Version AP 3.0 and earlier via multiple input fields that are mishandled in an Excel export. |